Agilent-technologies AGILENT U2761A Manual de usuario Pagina 57

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 123
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 56
Features and Functions 2
U2761A User’s Guide 39
The duty cycle setting does not apply to a Square waveform
used as the modulating waveform for AM, FM, or PM. A 50%
duty cycle is always used for a modulating Square waveform.
The duty cycle setting applies only to a Square waveform
carrier.
Soft Front Panel Operation
After selecting Square at the top panel as shown in
Figure 2- 2, on the Duty Cycle panel below, input the desired
duty cycle value.
Figure 2-8 Panel view of the duty cycle section
Remote Interface Operation
FUNCtion:SQUare:DCYCle <percent>
The APPLy command automatically sets the duty cycle to
50%.
Vista de pagina 56
1 2 ... 52 53 54 55 56 57 58 59 60 61 62 ... 122 123

Comentarios a estos manuales

Sin comentarios