Pagina 1 - Agilent 4156C

Agilent TechnologiesAgilent 4155CSemiconductor Parameter AnalyzerAgilent 4156CPrecision Semiconductor Parameter AnalyzerUser’s Guide: Measurement and

Pagina 2 - Restricted Rights Legend

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6ContentsNormal Sweep and Knob Sweep Measurements . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 3

3-22 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sampling MeasurementsMeasurement FunctionsParametersTo set up the logarithmic sampling measureme

Pagina 4

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 3-23Sampling MeasurementsMeasurement FunctionsTable 3-3 Effective Parameter Valuesa Number of units

Pagina 5 - Safety Summary

3-24 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sampling MeasurementsDefining Measurement ConditionsDefining Measurement Conditions This section

Pagina 6

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 3-25Sampling MeasurementsDefining Measurement Conditions4 Setting the display mode to show measureme

Pagina 7 - Safety Symbols

3-26 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sampling MeasurementsDefining Measurement ConditionsTo Define Measurement Units 1. Press Chan ke

Pagina 8 - In This Manual

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 3-27Sampling MeasurementsDefining Measurement ConditionsTo Set up Sampling Parameters 1. Confirm tha

Pagina 9

3-28 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sampling MeasurementsDefining Measurement ConditionsThe following figure shows the relation betw

Pagina 10 - Contents

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 3-29Sampling MeasurementsDefining Measurement ConditionsTo Set up Constant Output 1. Define CONST un

Pagina 11

3-30 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sampling MeasurementsDefining Measurement ConditionsTo Set up PGU Output 1. Define PGU to be VPU

Pagina 12

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 3-31Sampling MeasurementsDefining Measurement ConditionsTo modify the UNIT and NAME fieldsModify the

Pagina 13

ContentsAgilent 4155C/4156C User’s Guide Vol.2, Edition 6Step 1. Prepare for the measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 14

3-32 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sampling MeasurementsDefining Measurement ConditionsTo Define Stop Conditions The measurement st

Pagina 15

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 3-33Sampling MeasurementsDefining Measurement ConditionsTo Display Graphics Results 1. Press Display

Pagina 16

3-34 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sampling MeasurementsDefining Measurement ConditionsTo Display List Results 1. Press Display key

Pagina 17

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 3-35Sampling MeasurementsDefining Measurement ConditionsTo Execute or Stop Measurement • To execute

Pagina 18

3-36 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sampling MeasurementsMaking a MeasurementMaking a MeasurementIn this section, you learn how to e

Pagina 19 - 1 Sweep Measurements

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 3-37Sampling MeasurementsMaking a MeasurementStep 3. Define the channel assignments You set the conn

Pagina 20

3-38 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sampling MeasurementsMaking a MeasurementStep 4. Set up the measurement parameters You set the o

Pagina 21

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 3-39Sampling MeasurementsMaking a Measurement4. Set the CONSTANT table as shown below:This setup is

Pagina 22 - Basic Sweep Measurement

3-40 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sampling MeasurementsMaking a MeasurementStep 5. Set up the results display You set the results

Pagina 23

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 3-41Sampling MeasurementsMaking a MeasurementStep 6. Execute the measurement Press Single front-pane

Pagina 24

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6ContentsMaximum Measurement Value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 25

3-42 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sampling MeasurementsMaking a MeasurementIf you change the results display to the GRAPH/LIST: LI

Pagina 26

4 Quasi-static C-V Measurements

Pagina 27

4-2 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Quasi-static C-V MeasurementsThis chapter consists of the following sections which explains how t

Pagina 28

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 4-3Quasi-static C-V MeasurementsMeasurement FunctionsMeasurement FunctionsFor quasi-static C-V (QSCV

Pagina 29 - Pulse Sweep Measurement

4-4 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Quasi-static C-V MeasurementsMeasurement FunctionsOperationIn the QSCV measurement, the 4155C/415

Pagina 30

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 4-5Quasi-static C-V MeasurementsMeasurement FunctionsFigure 4-1 VAR1 Output and Measurement Items of

Pagina 31

4-6 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Quasi-static C-V MeasurementsMeasurement FunctionsParametersSpecify the following parameters for

Pagina 32

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 4-7Quasi-static C-V MeasurementsMeasurement FunctionsSpecify the following parameters to define the

Pagina 33

4-8 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Quasi-static C-V MeasurementsDefining Measurement ConditionsDefining Measurement Conditions This

Pagina 34

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 4-9Quasi-static C-V MeasurementsDefining Measurement Conditions4 Setting the display mode to show me

Pagina 35 - VNAME and INAME

ContentsAgilent 4155C/4156C User’s Guide Vol.2, Edition 6To Zoom the Display Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 36 - To Set up Primary Sweep

4-10 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Quasi-static C-V MeasurementsDefining Measurement ConditionsTo Define Measurement Units Press th

Pagina 37 - To Set up Secondary Sweep

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 4-11Quasi-static C-V MeasurementsDefining Measurement ConditionsTo Set up QSCV Sweep SourceThe QSCV

Pagina 38 - To Set up Synchronous Sweep

4-12 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Quasi-static C-V MeasurementsDefining Measurement Conditions8. DELAY TIMEEnter the delay time. 0

Pagina 39

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 4-13Quasi-static C-V MeasurementsDefining Measurement ConditionsTo Set up Constant Output Constant s

Pagina 40 - To Set up SMU Pulsed Output

4-14 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Quasi-static C-V MeasurementsDefining Measurement ConditionsTo Define Measurement ConditionsPres

Pagina 41 - Pulse Parameters

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 4-15Quasi-static C-V MeasurementsDefining Measurement ConditionsTo Display Graphics Results 1. Press

Pagina 42

4-16 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Quasi-static C-V MeasurementsDefining Measurement ConditionsTo Display List Results 1. Press the

Pagina 43

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 4-17Quasi-static C-V MeasurementsDefining Measurement ConditionsTo Execute or Stop Measurement To ex

Pagina 44

4-18 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Quasi-static C-V MeasurementsMaking a MeasurementMaking a MeasurementIn this section, you learn

Pagina 45

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 4-19Quasi-static C-V MeasurementsMaking a MeasurementStep 3. Define the channel assignments Set the

Pagina 46

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6ContentsPower Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 47

4-20 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Quasi-static C-V MeasurementsMaking a MeasurementStep 4. Set up the source parameters Set the ou

Pagina 48

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 4-21Quasi-static C-V MeasurementsMaking a Measurement4. Set the TIMING table. The following values a

Pagina 49 - Interlock/LED Cable

4-22 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Quasi-static C-V MeasurementsMaking a MeasurementStep 5. Set up the measurement parameters Set t

Pagina 50 - Triaxial Cables

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 4-23Quasi-static C-V MeasurementsMaking a Measurement4. Enable or disable the leakage current compen

Pagina 51

4-24 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Quasi-static C-V MeasurementsMaking a MeasurementStep 6. Set up the results display Set the resu

Pagina 52

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 4-25Quasi-static C-V MeasurementsMaking a MeasurementStep 7. Execute the measurement Press the Singl

Pagina 53

4-26 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Quasi-static C-V MeasurementsMaximum Measurement ValueMaximum Measurement ValueNOTE The maximum

Pagina 54 - Sweep Measurements

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 4-27Quasi-static C-V MeasurementsMaximum Measurement ValueFigure 4-3 Maximum Measurement Value Using

Pagina 55

4-28 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Quasi-static C-V MeasurementsConsidering Measurement AccuracyConsidering Measurement AccuracyNOT

Pagina 56

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 4-29Quasi-static C-V MeasurementsConsidering Measurement AccuracyTable 4-1 Constant Value for calcul

Pagina 57

ContentsAgilent 4155C/4156C User’s Guide Vol.2, Edition 6Measurement Sequence. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 58 - Figure 1-8 Sweep Setup Screen

4-30 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Quasi-static C-V MeasurementsConsidering Measurement Accuracy10 nA Ap 0.51 0.51 0.52 0.52Bp 0.03

Pagina 59

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 4-31Quasi-static C-V MeasurementsConsidering Measurement AccuracyTable 4-2 Constant Value for calcul

Pagina 60

4-32 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Quasi-static C-V MeasurementsConsidering Measurement AccuracyTable 4-3 Conditions for Calculatin

Pagina 61

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 4-33Quasi-static C-V MeasurementsConsidering Measurement AccuracyFigure 4-5 Calculation Example of M

Pagina 62

4-34 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Quasi-static C-V MeasurementsConsidering Measurement AccuracyFigure 4-6 Calculation Example of M

Pagina 63 - 2 Knob Sweep Measurements

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 4-35Quasi-static C-V MeasurementsConsidering Measurement AccuracyFigure 4-7 Calculation Example of M

Pagina 64

4-36 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Quasi-static C-V MeasurementsConsidering Measurement AccuracyFigure 4-8 Calculation Example of M

Pagina 65

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 4-37Quasi-static C-V MeasurementsConsidering Measurement AccuracyFigure 4-9 Calculation Example of M

Pagina 66

4-38 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Quasi-static C-V MeasurementsConsidering Measurement AccuracyFigure 4-10 Calculation Example of

Pagina 67

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 4-39Quasi-static C-V MeasurementsConsidering Measurement AccuracyFigure 4-11 Calculation Example of

Pagina 68

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6ContentsTo Control Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 69

4-40 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Quasi-static C-V MeasurementsConsidering Measurement AccuracyFigure 4-12 Calculation Example of

Pagina 70 - KNOB SWEEP screen

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 4-41Quasi-static C-V MeasurementsConsidering Measurement AccuracyFigure 4-13 Calculation Example of

Pagina 71 - To Use User Function

4-42 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Quasi-static C-V MeasurementsConsidering Measurement AccuracyFigure 4-14 Calculation Example of

Pagina 72 - Executing Measurements

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 4-43Quasi-static C-V MeasurementsConsidering Measurement AccuracyFigure 4-15 Calculation Example of

Pagina 73

4-44 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Quasi-static C-V MeasurementsConsidering Measurement AccuracyFigure 4-16 Calculation Example of

Pagina 74 - To Execute Measurements

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 4-45Quasi-static C-V MeasurementsConsidering Measurement AccuracyFigure 4-17 Calculation Example of

Pagina 75 - To Stop Measurement

4-46 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Quasi-static C-V MeasurementsConsidering Measurement AccuracyFigure 4-18 Calculation Example of

Pagina 76

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 4-47Quasi-static C-V MeasurementsConsidering Measurement AccuracyFigure 4-19 Calculation Example of

Pagina 77 - To copy knob sweep setups

4-48 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Quasi-static C-V MeasurementsConsidering Measurement AccuracyFigure 4-20 Calculation Example of

Pagina 78 - Knob Sweep Measurements

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 4-49Quasi-static C-V MeasurementsConsidering Measurement AccuracyFigure 4-21 Calculation Example of

Pagina 79 - 3 Sampling Measurements

ContentsAgilent 4155C/4156C User’s Guide Vol.2, Edition 6@L1CO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 80

4-50 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Quasi-static C-V MeasurementsConsidering Measurement AccuracyFigure 4-22 Calculation Example of

Pagina 81

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 4-51Quasi-static C-V MeasurementsConsidering Measurement AccuracyFigure 4-23 Calculation Example of

Pagina 82

4-52 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Quasi-static C-V MeasurementsConsidering Measurement AccuracyFigure 4-24 Calculation Example of

Pagina 83

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 4-53Quasi-static C-V MeasurementsConsidering Measurement AccuracyFigure 4-25 Calculation Example of

Pagina 84

4-54 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Quasi-static C-V MeasurementsConsidering Measurement AccuracyFigure 4-26 Calculation Example of

Pagina 86 - Meas.time

5-2 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Stress ForceThis chapter explains how to execute stress force, and consists of the following sect

Pagina 87 - Sampling Completion

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 5-3Stress ForceStress FunctionStress Function The 4155C/4156C can force both dc stress and ac stress

Pagina 88 - Val of EVENT

5-4 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Stress ForceStress FunctionStress Output Channels Stress output channel is defined as the unit us

Pagina 89

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 5-5Stress ForceStress FunctionSwitching Channels Connected to DUTThe 4155C/4156C can control Agilent

Pagina 90

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Contents

Pagina 91 - Linear Sampling Measurement

5-6 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Stress ForceStress FunctionStress Mode You set stress mode to the pulse count mode or duration mo

Pagina 92

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 5-7Stress ForceStress FunctionStress Force Sequence This section explains the source output sequence

Pagina 93

5-8 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Stress ForceStress FunctionNOTE Pulse Waveform when Stress Stops When you set the duration mode o

Pagina 94 - Example Operation

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 5-9Stress ForceStress FunctionFigure 5-1 Example of the Stress Force Sequence • output sequence from

Pagina 95

5-10 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Stress ForceStress FunctionStress Stop Function at Abnormal Status On the STRESS: STRESS SETUP s

Pagina 96 - TOTAL SAMP.TIME

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 5-11Stress ForceDefining Stress ConditionsDefining Stress ConditionsThis section covers the tasks fo

Pagina 97

5-12 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Stress ForceDefining Stress ConditionsThe following illustrates the basic procedures for stress

Pagina 98 - @TIME Value

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 5-13Stress ForceDefining Stress ConditionsTo Set up Stress Source Channels 1. Press Stress key in th

Pagina 99

5-14 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Stress ForceDefining Stress ConditionsExample The following figure shows an example setup to set

Pagina 100 - Parameters

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 5-15Stress ForceDefining Stress ConditionsTo Set up Stress Condition/Timing 1. Press Stress key in t

Pagina 101 - HOLD TIME

1 Sweep Measurements

Pagina 102

5-16 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Stress ForceDefining Stress ConditionsTo set hold timeIn the HOLD TIME field, set desired value.

Pagina 103

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 5-17Stress ForceDefining Stress ConditionsTo Set up ac (Pulse) Output 1. Press the Stress key in the

Pagina 104 - To Define Measurement Units

5-18 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Stress ForceDefining Stress ConditionsDelay timeThe following figure shows the meaning of delay

Pagina 105

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 5-19Stress ForceDefining Stress ConditionsTo Set up dc Output 1. Press Stress key in the PAGE CONTRO

Pagina 106

5-20 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Stress ForceDefining Stress ConditionsTo Force Stress Press Stress key in the MEASUREMENT key gr

Pagina 107 - To Set up Constant Output

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 5-21Stress ForceDefining Stress ConditionsExample The following figure shows an example of STRESS: S

Pagina 108 - To Set up PGU Output

5-22 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Stress ForceDefining Stress Conditions

Pagina 109

6 Analyzing Measurement Results

Pagina 110 - To Define Stop Conditions

6-2 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Analyzing Measurement ResultsYou can analyze measurement results by using lines, markers, and cur

Pagina 111 - To Display Graphics Results

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 6-3Analyzing Measurement ResultsAnalysis FunctionAnalysis Function The 4155C/4156C provides the foll

Pagina 112 - To Display List Results

Notices© Agilent Technologies 2001 - 2008No part of this manual may be reproduced in any form or by any means (including elec-tronic storage and retri

Pagina 113

1-2 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sweep MeasurementsThis chapter consists of the following sections which describes how to execute

Pagina 114 - Charge Voltage

6-4 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Analyzing Measurement ResultsAnalysis FunctionMarker on the GRAPH/LIST: GRAPHICS screen Figure 6-

Pagina 115 - Chan front-panel key

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 6-5Analyzing Measurement ResultsAnalysis Function• specifying the position for direct keyboard calcu

Pagina 116

6-6 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Analyzing Measurement ResultsAnalysis FunctionMarker on the GRAPH/LIST: LIST screen Figure 6-2 Ma

Pagina 117

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 6-7Analyzing Measurement ResultsAnalysis FunctionMoving the markerBasically, you can move the marker

Pagina 118

6-8 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Analyzing Measurement ResultsAnalysis FunctionCursor Cursors are used to specify the position for

Pagina 119

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 6-9Analyzing Measurement ResultsAnalysis FunctionLine Drawing You can draw up to two lines in plotti

Pagina 120 - Making a Measurement

6-10 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Analyzing Measurement ResultsAnalysis Function• Tangent line mode: can draw tangent line to mark

Pagina 121

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 6-11Analyzing Measurement ResultsAnalysis FunctionScaling Functions You can change the axis scales a

Pagina 122

6-12 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Analyzing Measurement ResultsAnalysis FunctionOverlay Display Function You can overlay a measure

Pagina 123 - Measurement Functions

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 6-13Analyzing Measurement ResultsManual AnalysisManual Analysis You can position lines, markers, and

Pagina 124 - Operation

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 1-3Sweep MeasurementsMeasurement FunctionsMeasurement FunctionsFor sweep measurements, the sweep sou

Pagina 125

6-14 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Analyzing Measurement ResultsManual AnalysisTo Specify a Measurement Point on Curve 1. Select MA

Pagina 126

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 6-15Analyzing Measurement ResultsManual AnalysisExample The following figure shows an example to mov

Pagina 127 - NOTE Integration Time

6-16 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Analyzing Measurement ResultsManual AnalysisTo Specify between Measurement Points on Curve 1. Se

Pagina 128

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 6-17Analyzing Measurement ResultsManual AnalysisExample The following figure shows an example to mov

Pagina 129

6-18 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Analyzing Measurement ResultsManual AnalysisTo Display or Move Cursor 1. Select MARKER/CURSOR pr

Pagina 130

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 6-19Analyzing Measurement ResultsManual AnalysisTo Adjust Display Range to Measurement Curve Automat

Pagina 131 - To Set up QSCV Sweep Source

6-20 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Analyzing Measurement ResultsManual AnalysisTo Center Display at Cursor Location 1. Position cur

Pagina 132 - To Set up Stop Condition

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 6-21Analyzing Measurement ResultsManual AnalysisTo turn off the line intercept and gradient displayS

Pagina 133

6-22 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Analyzing Measurement ResultsManual AnalysisTo Draw Line through Specified Point with Specified

Pagina 134 - measurement

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 6-23Analyzing Measurement ResultsManual AnalysisExample The following figure shows an example to dra

Pagina 135

1-4 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sweep MeasurementsMeasurement FunctionsBasic Sweep Measurement Basic sweep measurement uses one s

Pagina 136

6-24 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Analyzing Measurement ResultsManual AnalysisTo Draw Tangent to Specified Point of Measurement Cu

Pagina 137

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 6-25Analyzing Measurement ResultsManual AnalysisExample The following figure shows an example to dra

Pagina 138

6-26 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Analyzing Measurement ResultsManual AnalysisTo Draw Regression Line for Specified Region 1. Sele

Pagina 139

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 6-27Analyzing Measurement ResultsManual AnalysisIf it seems that only one cursor is displayed, the c

Pagina 140

6-28 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Analyzing Measurement ResultsManual AnalysisTo Display and Select a Line 1. Select LINE primary

Pagina 141

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 6-29Analyzing Measurement ResultsManual AnalysisTo Change Data Variable on Graph 1. Select DISPLAY S

Pagina 142

6-30 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Analyzing Measurement ResultsManual AnalysisTo Change Range of X or Y Axis Scale 1. Select DISPL

Pagina 143

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 6-31Analyzing Measurement ResultsManual AnalysisTo Change Variable Assigned to X, Y1, or Y2 Axis 1.

Pagina 144

6-32 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Analyzing Measurement ResultsManual AnalysisTo Overlay an Internal Memory Measurement Curve onto

Pagina 145

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 6-33Analyzing Measurement ResultsManual AnalysisExample The following figure shows an example to ove

Pagina 146 - Maximum Measurement Value

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 1-5Sweep MeasurementsMeasurement FunctionsFigure 1-1 Basic Sweep Measurement To set up basic sweep m

Pagina 147 - Quasi-static C-V Measurements

6-34 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Analyzing Measurement ResultsManual AnalysisTo Scroll the LIST screen • Press an arrow key of th

Pagina 148

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 6-35Analyzing Measurement ResultsManual AnalysisTo Display or Move Marker on LIST screen 1. Select M

Pagina 149

6-36 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Analyzing Measurement ResultsManual AnalysisTo Change Variables of LIST screen 1. Select RE-SETU

Pagina 150

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 6-37Analyzing Measurement ResultsAutomatic AnalysisAutomatic Analysis You set up automatic analysis

Pagina 151

6-38 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Analyzing Measurement ResultsAutomatic AnalysisTo Draw Line by Specifying Two Points 1. Press Di

Pagina 152

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 6-39Analyzing Measurement ResultsAutomatic AnalysisData condition mode specifies a point related to

Pagina 153

6-40 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Analyzing Measurement ResultsAutomatic AnalysisTo Draw Line by Specifying Gradient and One Point

Pagina 154

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 6-41Analyzing Measurement ResultsAutomatic AnalysisData condition mode specifies a point related to

Pagina 155

6-42 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Analyzing Measurement ResultsAutomatic AnalysisTo Draw Tangent to Specified Measurement Point 1.

Pagina 156

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 6-43Analyzing Measurement ResultsAutomatic AnalysisExample The following figure shows an example set

Pagina 157

1-6 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sweep MeasurementsMeasurement Functionsstart Start value of sweep. For logarithmic sweep, start

Pagina 158

6-44 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Analyzing Measurement ResultsAutomatic AnalysisTo Draw Regression Line by Specifying Two Points

Pagina 159

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 6-45Analyzing Measurement ResultsAutomatic AnalysisRegression calculation is performed in the range

Pagina 160

6-46 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Analyzing Measurement ResultsAutomatic AnalysisExample The following figure shows an example set

Pagina 161 - QSCV Measurement Voltage (V)

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 6-47Analyzing Measurement ResultsAutomatic AnalysisTo Display Marker at Specified Point 1. Press Dis

Pagina 162

6-48 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Analyzing Measurement ResultsAutomatic AnalysisExample The following figure shows an example set

Pagina 163

7 Measurement Units and Functions

Pagina 164

7-2 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Measurement Units and FunctionsThis chapter explains measurement units and measurement functions

Pagina 165

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 7-3Measurement Units and FunctionsMeasurement UnitsMeasurement UnitsThe 4155C/4156C and 41501A/B hav

Pagina 166

7-4 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Measurement Units and FunctionsMeasurement UnitsSMU - Source Monitor UnitSMU can force a constant

Pagina 167

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 7-5Measurement Units and FunctionsMeasurement UnitsType of SMUsFollowing three types of SMUs are ava

Pagina 168

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 1-7Sweep MeasurementsMeasurement FunctionsSubordinate Sweep Measurement For subordinate sweep measur

Pagina 169

7-6 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Measurement Units and FunctionsMeasurement UnitsHRSMU - High Resolution SMUFigure 7-3 HRSMU Outpu

Pagina 170

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 7-7Measurement Units and FunctionsMeasurement UnitsTable 7-2 HRSMU Measurement Voltage Values and Re

Pagina 171

7-8 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Measurement Units and FunctionsMeasurement UnitsTable 7-4 HRSMU Measurement Current Values and Re

Pagina 172

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 7-9Measurement Units and FunctionsMeasurement UnitsMPSMU - Medium Power SMUFigure 7-4 MPSMU Output a

Pagina 173

7-10 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Measurement Units and FunctionsMeasurement UnitsTable 7-6 MPSMU Measurement Voltage Values and R

Pagina 174

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 7-11Measurement Units and FunctionsMeasurement UnitsTable 7-8 MPSMU Measurement Current Values and R

Pagina 175 - 5Stress Force

7-12 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Measurement Units and FunctionsMeasurement UnitsHPSMU - High Power SMUFigure 7-5 HPSMU Output an

Pagina 176

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 7-13Measurement Units and FunctionsMeasurement UnitsTable 7-10 HPSMU Measurement Voltage Values and

Pagina 177 - Stress Function

7-14 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Measurement Units and FunctionsMeasurement UnitsTable 7-12 HPSMU Measurement Current Values and

Pagina 178 - Stress Output Channels

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 7-15Measurement Units and FunctionsMeasurement UnitsSMU Pulse OutputWhen SMU is pulsed source, set p

Pagina 179 - External Stress Source

1-8 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sweep MeasurementsMeasurement FunctionsParametersThe parameters for primary sweep source (VAR1) a

Pagina 180 - Stress Mode

7-16 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Measurement Units and FunctionsMeasurement Units• Voltage ComplianceIf you use SMU as pulse curr

Pagina 181 - Stress Force Sequence

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 7-17Measurement Units and FunctionsMeasurement UnitsVSU - Voltage Source UnitFigure 7-6 shows a simp

Pagina 182 - Example

7-18 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Measurement Units and FunctionsMeasurement UnitsVMU - Voltage Monitor UnitThe VMU has two measur

Pagina 183

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 7-19Measurement Units and FunctionsMeasurement UnitsTable 7-13 VMU Voltage Ranges and Resolutions Me

Pagina 184 - Abnormal Status

7-20 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Measurement Units and FunctionsMeasurement UnitsPGU - Pulse Generator UnitTwo PGUs (pulse genera

Pagina 185 - Defining Stress Conditions

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 7-21Measurement Units and FunctionsMeasurement UnitsOutput ImpedanceFor the PGU pulsed outputs, you

Pagina 186

7-22 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Measurement Units and FunctionsMeasurement UnitsLeading Edge and Trailing Edge Transition TimeTh

Pagina 187 - To disable a unit

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 7-23Measurement Units and FunctionsComplianceCompliance Compliance is available for SMU (HPSMU, MPSM

Pagina 188

7-24 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Measurement Units and FunctionsComplianceFigure 7-9 Relation of Compliance and Output Current Co

Pagina 189

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 7-25Measurement Units and FunctionsComplianceTable 7-18 V Compliance Resolution Table 7-19 I Complia

Pagina 190 - To set hold time

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 1-9Sweep MeasurementsMeasurement FunctionsSynchronous Sweep Measurement For synchronous sweep measur

Pagina 191 - To Set up ac (Pulse) Output

7-26 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Measurement Units and FunctionsComplianceTable 7-20 I Compliance Resolution HPSMU 2 V 1 pA to 10

Pagina 192 - Delay time

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 7-27Measurement Units and FunctionsCompliancePower Compliance In addition to V compliance or I compl

Pagina 193 - To Set up dc Output

7-28 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Measurement Units and FunctionsComplianceFigure 7-10 Power Compliance Output Area If you specify

Pagina 194 - To Force Stress

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 7-29Measurement Units and FunctionsMeasurement Ranging ModeMeasurement Ranging Mode Before executing

Pagina 195

7-30 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Measurement Units and FunctionsMeasurement Ranging ModeAuto Ranging The monitor unit automatical

Pagina 196 - Stress Force

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 7-31Measurement Units and FunctionsMeasurement Ranging ModeLimited Auto Ranging Limited auto ranging

Pagina 197

7-32 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Measurement Units and FunctionsMeasurement Ranging ModeCompliance Range Compliance range is avai

Pagina 198

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 7-33Measurement Units and FunctionsMeasurement Ranging ModeEnhanced Auto Ranging for Current Measure

Pagina 199 - Analysis Function

7-34 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Measurement Units and FunctionsMeasurement TimeMeasurement Time Measurement time depends on inte

Pagina 200

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 7-35Measurement Units and FunctionsMeasurement TimeMEDIUM Medium mode automatically sets the integra

Pagina 201 - Moving the marker

1-10 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sweep MeasurementsMeasurement FunctionsParametersThe parameters for primary sweep source (VAR1)

Pagina 202

7-36 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Measurement Units and FunctionsMeasurement TimeTable 7-24 Integration Time in Short Mode (Integ

Pagina 203

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 7-37Measurement Units and FunctionsMeasurement TimeOverhead TimeThe overhead time is the time requir

Pagina 204

7-38 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Measurement Units and FunctionsSMU FilterSMU Filter You can set SMU filter to on or off for samp

Pagina 205 - Line Drawing

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 7-39Measurement Units and FunctionsSelf-calibrationSelf-calibrationAgilent 4155C/4156C provides the

Pagina 206

7-40 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Measurement Units and FunctionsZero Offset CancelZero Offset Cancel The 4155C/4156C has zero off

Pagina 207 - Scaling Functions

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 7-41Measurement Units and FunctionsZero Offset CancelTable 7-25 Ranging Mode Available for Offset Me

Pagina 208 - Automatic Analysis Function

7-42 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Measurement Units and FunctionsZero Offset CancelTo Perform Offset CancelOffset cancel is automa

Pagina 209 - Manual Analysis

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 7-43Measurement Units and FunctionsQSCV Zero Offset CancelQSCV Zero Offset CancelThis function is av

Pagina 210 - To move marker fast

7-44 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Measurement Units and FunctionsQSCV Zero Offset CancelTable 7-27 Measurement Condition for the O

Pagina 211

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 7-45Measurement Units and FunctionsQSCV Zero Offset CancelTo Perform Offset CancelSet the ZERO CANCE

Pagina 212

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 1-11Sweep MeasurementsMeasurement FunctionsPulse Sweep Measurement For a sweep measurement, a sweep

Pagina 213

7-46 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Measurement Units and FunctionsOperation StatesOperation States The 4155C/4156C has the followin

Pagina 214 - To Display or Move Cursor

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 7-47Measurement Units and FunctionsOperation StatesStress Force StateIn the stress force state, the

Pagina 215 - To Zoom the Display Range

7-48 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Measurement Units and FunctionsOperation States• From measurement/stress states to standby state

Pagina 216

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 7-49Measurement Units and FunctionsOutput SequenceOutput Sequence When you perform measurements or f

Pagina 217

7-50 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Measurement Units and FunctionsOutput SequenceSequential Mode Default output sequence in the seq

Pagina 218 - Gradient

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 7-51Measurement Units and FunctionsOutput SequenceExample Output sequence in the following condition

Pagina 219

7-52 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Measurement Units and FunctionsOutput SequenceSimultaneous Mode The simultaneous mode is availab

Pagina 220

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 7-53Measurement Units and FunctionsOutput SequenceExample Output sequence in the following condition

Pagina 221

7-54 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Measurement Units and FunctionsMeasurement SequenceMeasurement SequenceThe 4155C/4156C performs

Pagina 222

8 Support Functions

Pagina 224 - To Display Grid on the Graph

1-12 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sweep MeasurementsMeasurement FunctionsFigure 1-5 SMU Pulse ParametersSpecify SMU pulse paramete

Pagina 225

8-2 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Support FunctionsThis chapter explains functions that can be used in measurements. Agilent 4155C/

Pagina 226

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 8-3Support FunctionsUser Function and User VariableUser Function and User VariableUser function and

Pagina 227

8-4 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Support FunctionsUser Function and User VariableYou can get the measurement results by using the

Pagina 228

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 8-5Support FunctionsUser Function and User VariableUser Function A user function consists of one or

Pagina 229

8-6 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Support FunctionsUser Function and User VariableUser Variable A user variable is a data variable

Pagina 230 - To Scroll the LIST screen

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 8-7Support FunctionsUser Function and User VariableCalculation between variables of different length

Pagina 231 - To turn off marker

8-8 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Support FunctionsUser Function and User VariableSyntax of Data Variable Name A data variable name

Pagina 232

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 8-9Support FunctionsUser Function and User VariableExpressionAn expression can be used for following

Pagina 233 - Automatic Analysis

8-10 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Support FunctionsUser Function and User Variablemonadic operatorMonadic operator performs operat

Pagina 234 - Display front-panel key

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 8-11Support FunctionsUser Function and User VariableFigure 8-3 Numeric Constant scientific constantT

Pagina 235

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 1-13Sweep MeasurementsMeasurement FunctionsNOTE Pulse width If the measurement settings do not meet

Pagina 236

8-12 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Support FunctionsUser Function and User VariableArithmetic operator precedence When an expressio

Pagina 237

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 8-13Support FunctionsStandby FunctionStandby FunctionThe 4155C/4156C can force standby outputs befor

Pagina 238

8-14 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Support FunctionsStandby FunctionAvailable Units and Output ValuesFollowing table shows the outp

Pagina 239

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 8-15Support FunctionsStandby FunctionOutput Sequence of Standby ChannelsOutput sequence of measureme

Pagina 240

8-16 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Support FunctionsStandby FunctionWhen Getting Setup FileUsually, the 4155C/4156C is in the idle

Pagina 241

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 8-17Support FunctionsStandby FunctionTo Use Standby Function1. Press Chan key in the PAGE CONTROL ke

Pagina 242

8-18 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Support FunctionsR-BOX ControlR-BOX Control Agilent 16441A R-Box must be used for applications w

Pagina 243

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 8-19Support FunctionsR-BOX ControlNon-Kelvin ConnectionsThe following figure shows the 16441A R-Box

Pagina 244

8-20 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Support FunctionsR-BOX ControlSetupsYou set resistance values in the SERIES RESISTANCE column on

Pagina 245

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 8-21Support FunctionsR-BOX ControlCircuit Diagram Figure 8-5 shows a simplified circuit diagram of a

Pagina 246 - • “QSCV Zero Offset Cancel”

1-14 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sweep MeasurementsDefining Measurement ConditionsDefining Measurement Conditions This section de

Pagina 247 - Measurement Units

8-22 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Support FunctionsR-BOX ControlFigure 8-5 Simplified Circuit Diagram of the 16441A R-Box

Pagina 248 - SMU - Source Monitor Unit

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 8-23Support FunctionsR-BOX ControlTo Use R-Box 1. Connect the 16441A R-Box to the 4155C/4156C and to

Pagina 249 - Type of SMUs

8-24 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Support FunctionsR-BOX ControlTo measure negative resistance characteristics The 16441A R-Box al

Pagina 250 - HRSMU - High Resolution SMU

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 8-25Support FunctionsSMU/PG Selector ControlSMU/PG Selector ControlThe 4155C/4156C can control the 1

Pagina 251

8-26 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Support FunctionsSMU/PG Selector ControlSetup and Switching ConditionsSetup of the SMU/PG SELECT

Pagina 252

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 8-27Support FunctionsSMU/PG Selector ControlTo Use Selector1. Press Stress key in the PAGE CONTROL k

Pagina 253 - MPSMU - Medium Power SMU

8-28 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Support FunctionsSMU/PG Selector ControlExample Following shows an example setup that connects t

Pagina 254

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 8-29Support FunctionsSwitching Matrix ControlSwitching Matrix ControlThe 4155C/4156C can control the

Pagina 255

8-30 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Support FunctionsSwitching Matrix Control7. Turn the instruments on.8. Set the 4155C/4156C to SY

Pagina 256 - HPSMU - High Power SMU

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 8-31Support FunctionsSwitching Matrix ControlTable 8-3 Connecting E5250AConnectors on E5250A Rear Pa

Pagina 257

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 1-15Sweep MeasurementsDefining Measurement Conditions4 Setting the display mode to show measurement

Pagina 258

8-32 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Support FunctionsSwitching Matrix ControlTo Control FunctionsTo control the E5250A functions, us

Pagina 259 - SMU Pulse Output

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 8-33Support FunctionsSwitching Matrix ControlStep 3. To initialize the E5250AIn the CONFIG MODE fiel

Pagina 260

8-34 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Support FunctionsSwitching Matrix ControlStep 6. To set bias port (if you use the bias port func

Pagina 261 - VSU - Voltage Source Unit

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 8-35Support FunctionsSwitching Matrix ControlStep 8. To select connection ruleIn the CONN RULE field

Pagina 262 - VMU - Voltage Monitor Unit

8-36 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Support FunctionsSwitching Matrix ControlStep 10. To define E5250A input connectionIn the E250A

Pagina 263

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 8-37Support FunctionsSwitching Matrix ControlTo Control ConnectionsTo control the matrix connections

Pagina 264 - PGU - Pulse Generator Unit

8-38 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Support FunctionsSwitching Matrix ControlStep 3. To change the enable input ports (for ARRAY dis

Pagina 265 - Pulse Count

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 8-39Support FunctionsSwitching Matrix ControlStep 5. To define the matrix connection (for ARRAY disp

Pagina 266 - Trigger Output

8-40 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Support FunctionsSwitching Matrix ControlStep 6. To define the matrix connection (for LIST displ

Pagina 267 - Compliance

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 8-41Support FunctionsSwitching Matrix ControlStep 7. To apply the connection information to the E525

Pagina 268

1-16 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sweep MeasurementsDefining Measurement ConditionsTo Define Measurement Units Press Chan front-pa

Pagina 269

8-42 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Support FunctionsTrigger FunctionTrigger Function Trigger function is used to perform measuremen

Pagina 270

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 8-43Support FunctionsTrigger FunctionSetup and restrictions•You cannot perform trigger outputs toget

Pagina 271 - Power Compliance

8-44 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Support FunctionsTrigger FunctionTrigger InputThe 4155C/4156C can receive an edge trigger (TTL l

Pagina 272

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 8-45Support FunctionsTrigger FunctionTrigger OutputThe 4155C/4156C triggers external instruments via

Pagina 273 - Measurement Ranging Mode

8-46 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Support FunctionsTrigger FunctionTrigger output delay time for pulsed sweep measurements. When u

Pagina 274 - Auto Ranging

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 8-47Support FunctionsTrigger FunctionStep delay time for staircase sweep measurements. When performi

Pagina 275 - Limited Auto Ranging

8-48 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Support FunctionsTrigger FunctionTrigger output function of PGUUsing the Agilent 41501A/B contai

Pagina 276 - Fixed Range

9 Built-in Functions

Pagina 277

9-2 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Built-in FunctionsThis chapter explains the following functions built in the Agilent 4155C/4156C,

Pagina 278 - Measurement Time

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 9-3Built-in FunctionsBuilt-in Function You can use built-in functions for the following:• In the exp

Pagina 279 - Medium front-panel key

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 1-17Sweep MeasurementsDefining Measurement Conditions6. DISCHARGE:Select ON secondary softkey to con

Pagina 280

9-4 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Built-in FunctionsABSABS Returns the absolute value of the expression.Syntax ABS(expression)Examp

Pagina 281 - To Specify Source Output Time

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 9-5Built-in FunctionsCONDCOND This function does the following:•If 1st expression < 2nd expressio

Pagina 282 - SMU Filter

9-6 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Built-in FunctionsDELTADELTA Returns the difference of the expression.Syntax DELTA(expression)Th

Pagina 283 - Self-calibration

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 9-7Built-in FunctionsDIFFDIFF Returns differential coefficient of 1st expression by 2nd expression.S

Pagina 284 - Zero Offset Cancel

9-8 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Built-in FunctionsEXPEXP Raises e to the power of expression.Syntax EXP(expression)Example To rai

Pagina 285

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 9-9Built-in FunctionsLGTLGT Returns the logarithm (base 10) of expression.Syntax LGT(expression)If t

Pagina 286 - To Perform Offset Cancel

9-10 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Built-in FunctionsMAVGMAVG Returns the moving average value of 1st expression. The 2nd expressio

Pagina 287 - QSCV Zero Offset Cancel

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 9-11Built-in FunctionsMAXMAX Returns the maximum sweep or sampling value.Syntax MAX(expression)For s

Pagina 288

9-12 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Built-in FunctionsRead Out Function The read out functions are built-in functions for reading va

Pagina 289

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 9-13Built-in Functions@CX@CX Returns the value of X coordinate at the active cursor position.Syntax:

Pagina 290 - Operation States

1-18 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sweep MeasurementsDefining Measurement ConditionsTo Set up Primary Sweep Primary sweep source is

Pagina 291 - Standby State

9-14 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Built-in Functions@IX@IX Returns the value of X coordinate at the cross point of LINE1 and LINE2

Pagina 292

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 9-15Built-in Functions@IY1@IY1 Returns the value of Y1 coordinate at the cross point of LINE1 and LI

Pagina 293 - Output Sequence

9-16 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Built-in Functions@L1CO@L1CO Returns the correlation coefficient of the regression for LINE1.Syn

Pagina 294 - Sequential Mode

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 9-17Built-in Functions@L1G1@L1G1 Returns the slope of LINE1 for Y1 axis.Syntax: @L1G1This function

Pagina 295

9-18 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Built-in Functions@L1G2@L1G2 Returns the slope of LINE1 for Y2 axis.Syntax: @L1G2This function

Pagina 296 - Simultaneous Mode

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 9-19Built-in Functions@L1X@L1X Returns the X intercept value (Y=0) of LINE1.Syntax: @L1XIf LINE1 is

Pagina 297

9-20 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Built-in Functions@L2G@L2G Returns the slope of LINE2.Syntax: @L2GIf there are Y1 and Y2 axes,

Pagina 298 - Measurement Sequence

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 9-21Built-in Functions@L2G1@L2G1 Returns the slope of LINE2 for Y1 axis.Syntax: @L2G1This function

Pagina 299 - 8 Support Functions

9-22 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Built-in Functions@L2G2@L2G2 Returns the slope of LINE2 for Y2 axis.Syntax: @L2G2This function

Pagina 300

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 9-23Built-in Functions@L2X@L2X Returns the X intercept value (Y=0) of LINE2.Syntax: @L2XIf LINE2 is

Pagina 301 - Output or Measurement Data

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 1-19Sweep MeasurementsDefining Measurement ConditionsTo Set up Secondary Sweep Secondary sweep sourc

Pagina 302 - Output data of PGU

9-24 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Built-in Functions@MX@MX Returns the value of the X coordinate at the marker location.Syntax: @

Pagina 303 - User Function

10 Connecting Measurement Devices

Pagina 304 - User Variable

10-2 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Connecting Measurement DevicesThis section describes how to connect device under test (DUT) to t

Pagina 305 - 10 ASSIGN @Hp4155 TO 800

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 10-3Connecting Measurement DevicesUsing Test FixtureUsing Test Fixture1. Press the Stop front-panel

Pagina 306 - Syntax of Data Variable Name

10-4 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Connecting Measurement DevicesUsing Test FixtureConnections for High Current MeasurementsWhen yo

Pagina 307 - Expression

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 10-5Connecting Measurement DevicesUsing Connector PlateUsing Connector PlateThis section provides th

Pagina 308

10-6 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Connecting Measurement DevicesUsing Connector PlateExample The following example connection can

Pagina 309

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 10-7Connecting Measurement DevicesUsing Connector PlateTo Measure Low ResistanceWhen you measure a l

Pagina 310

10-8 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Connecting Measurement DevicesUsing Connector PlateKelvin Connection Kelvin connections give goo

Pagina 311 - Standby Function

1-20 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sweep MeasurementsDefining Measurement ConditionsTo Set up Synchronous Sweep Synchronous sweep s

Pagina 312

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 1-21Sweep MeasurementsDefining Measurement ConditionsTo Set up Constant Output Constant voltage/curr

Pagina 313

• HerstellerbescheinigungGEÄUSCHEMISSIONLpa < 70 dBam Arbeitsplatznormaler Betriebnach DIN 45635 T. 19• Manufacturer’s DeclarationACOUSTIC NOISE EM

Pagina 314 - When Getting Setup File

1-22 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sweep MeasurementsDefining Measurement ConditionsTo Set up SMU Pulsed Output SMU pulse output so

Pagina 315 - To Use Standby Function

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 1-23Sweep MeasurementsDefining Measurement ConditionsPulse ParametersThe relation between the PERIOD

Pagina 316 - R-BOX Control

1-24 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sweep MeasurementsDefining Measurement ConditionsTo Set up PGU Output 1. Define PGU to be VPULSE

Pagina 317 - Kelvin Connections

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 1-25Sweep MeasurementsDefining Measurement ConditionsTo modify the UNIT and NAME fieldsModify the UN

Pagina 318

1-26 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sweep MeasurementsDefining Measurement ConditionsTo Set up Stop Condition1. Press Meas key in th

Pagina 319 - Circuit Diagram

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 1-27Sweep MeasurementsDefining Measurement ConditionsTo Display Graphics Results 1. Press Display ke

Pagina 320 - Support Functions

1-28 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sweep MeasurementsDefining Measurement ConditionsTo Display List Results 1. Press Display key in

Pagina 321 - To Use R-Box

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 1-29Sweep MeasurementsDefining Measurement ConditionsTo Execute or Stop Measurement • To execute a m

Pagina 322 - 16441A R-Box

1-30 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sweep MeasurementsMaking a MeasurementMaking a MeasurementIn this section, you learn how to exec

Pagina 323 - SMU/PG Selector Control

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 1-31Sweep MeasurementsMaking a MeasurementStep 1. Prepare for the measurement Before executing measu

Pagina 324 - Restrictions using Selector

Safety SummaryThe following general safety precautions must be observed during all phases of operation, service, and repair of this instrument. Failur

Pagina 325 - To Use Selector

1-32 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sweep MeasurementsMaking a MeasurementConnection between 4155C and 16442A/B:4155C cable 16442A/B

Pagina 326

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 1-33Sweep MeasurementsMaking a MeasurementStep 2. Mount your DUT on the test fixture 1. Select a sui

Pagina 327 - Switching Matrix Control

1-34 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sweep MeasurementsMaking a MeasurementWiring for the 4156C For this measurement, non-Kelvin conn

Pagina 328

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 1-35Sweep MeasurementsMaking a MeasurementStep 3. Define the channel assignments You set the connect

Pagina 329

1-36 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sweep MeasurementsMaking a MeasurementFigure 1-6 Channel Definition ScreenBCHANNELS: CHANNEL DEF

Pagina 330 - To Control Functions

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 1-37Sweep MeasurementsMaking a MeasurementStep 4. Define the user functions You define the user func

Pagina 331

1-38 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sweep MeasurementsMaking a MeasurementFigure 1-7 User Function Definition ScreenFigure 1-7 defin

Pagina 332

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 1-39Sweep MeasurementsMaking a MeasurementStep 5. Set up the measurement parameters You set the outp

Pagina 333

1-40 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sweep MeasurementsMaking a MeasurementFigure 1-8 Sweep Setup ScreenBMEASURE: SWEEP SETUP 01JAN29

Pagina 334

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 1-41Sweep MeasurementsMaking a MeasurementStep 6. Set up the results display You set the results dis

Pagina 335 - To Control Connections

• DO NOT SUBSTITUTE PARTS OR MODIFY INSTRUMENTBecause of the danger of introducing additional hazards, do not install substitute parts or perform any

Pagina 336

1-42 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sweep MeasurementsMaking a MeasurementFigure 1-9 Display Setup ScreenBDISPLAY: DISPLAY SETUP 01J

Pagina 337

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 1-43Sweep MeasurementsMaking a MeasurementStep 7. Execute the measurement Press Single front-panel k

Pagina 338

1-44 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sweep MeasurementsMaking a Measurement

Pagina 339 - To Use Matrix Setup File

2 Knob Sweep Measurements

Pagina 340 - Trigger Function

2-2 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Knob Sweep MeasurementsThis chapter explains how to execute knob sweep measurements. The knob swe

Pagina 341 - Single, Repeat, or Append)

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 2-3Knob Sweep MeasurementsMeasurement FunctionsMeasurement FunctionsThe knob sweep function allows y

Pagina 342 - Trigger Input

2-4 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Knob Sweep MeasurementsMeasurement FunctionsNormal Sweep and Knob Sweep MeasurementsTable 2-2 com

Pagina 343

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 2-5Knob Sweep MeasurementsMeasurement FunctionsFeatures of Knob Sweep Function The following are par

Pagina 344

2-6 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Knob Sweep MeasurementsMeasurement FunctionsStep TimeStep time is the time width of a sweep step

Pagina 345

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 2-7Knob Sweep MeasurementsMeasurement FunctionsSweep Step ValueFor the VAR1 channel, you do not set

Pagina 346

Safety SymbolsThe general definitions of safety symbols used on equipment or in manuals are listed below.Instruction manual symbol: the product will b

Pagina 347 - 9 Built-in Functions

2-8 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Knob Sweep MeasurementsMeasurement FunctionsKNOB SWEEP screen To start the knob sweep measurement

Pagina 348

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 2-9Knob Sweep MeasurementsMeasurement FunctionsAnalysis of the Knob Sweep Measurement Results On the

Pagina 349 - Built-in Function

2-10 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Knob Sweep MeasurementsExecuting MeasurementsExecuting MeasurementsYou can easily execute the kn

Pagina 350

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 2-11Knob Sweep MeasurementsExecuting MeasurementsTo Define Measurement Units Press Chan front-panel

Pagina 351

2-12 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Knob Sweep MeasurementsExecuting MeasurementsTo Execute Measurements 1. Press the green key, the

Pagina 352

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 2-13Knob Sweep MeasurementsExecuting MeasurementsExampleThe following figure shows an example to set

Pagina 353

2-14 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Knob Sweep MeasurementsExecuting MeasurementsTo Change Measurement ConditionsTo change the measu

Pagina 354

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 2-15Knob Sweep MeasurementsExecuting MeasurementsTo copy knob sweep setupsSelect SETUP COPY primary

Pagina 355

2-16 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Knob Sweep MeasurementsExecuting Measurements

Pagina 356

3 Sampling Measurements

Pagina 357

In This Manual This manual provides information for measurement and analysis functions of Agilent 4155C/4156C, and consists of the following chapters:

Pagina 358 - Read Out Function

3-2 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sampling MeasurementsThis chapter explains how to execute sampling measurements, and consists of

Pagina 359

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 3-3Sampling MeasurementsMeasurement FunctionsMeasurement FunctionsFor a sampling measurement, you ca

Pagina 360

3-4 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sampling MeasurementsMeasurement FunctionsSampling Interval and Measurement TimeWhen the sampling

Pagina 361

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 3-5Sampling MeasurementsMeasurement FunctionsFigure 3-1 Sampling Measurement Operation SummaryPGU Ou

Pagina 362

3-6 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sampling MeasurementsMeasurement FunctionsSampling measurement is executed as explained below.1.

Pagina 363

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 3-7Sampling MeasurementsMeasurement FunctionsSampling Measurement DataMeasurement parameters of samp

Pagina 364

3-8 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sampling MeasurementsMeasurement FunctionsFor example, if Thold=10 ms, Tinterval=5 ms, and @TIME

Pagina 365

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 3-9Sampling MeasurementsMeasurement FunctionsSampling Completion The sampling measurement completes

Pagina 366

3-10 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sampling MeasurementsMeasurement FunctionsTo use this function, the INITIAL INTERVAL value must

Pagina 367

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 3-11Sampling MeasurementsMeasurement FunctionsSource Output Sequence and Time OriginSource unit outp

Pagina 368

ContentsAgilent 4155C/4156C User’s Guide Vol.2, Edition 61. Sweep MeasurementsMeasurement Functions. . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 369

3-12 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sampling MeasurementsMeasurement Functions• SEQUENTIAL modeSource units starts output in the ord

Pagina 370

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 3-13Sampling MeasurementsMeasurement FunctionsLinear Sampling Measurement Linear sampling mode keeps

Pagina 371

3-14 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sampling MeasurementsMeasurement Functions3. If the sampling completion condition is not satisfi

Pagina 372

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 3-15Sampling MeasurementsMeasurement FunctionsHOLD TIME Hold time. This is the time from starting s

Pagina 373 - Using Test Fixture

3-16 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sampling MeasurementsMeasurement FunctionsThinned-out Sampling Measurement Thinned-out sampling

Pagina 374 - Substrate

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 3-17Sampling MeasurementsMeasurement Functions3. If the sampling completion condition is not satisfi

Pagina 375 - Using Connector Plate

3-18 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sampling MeasurementsMeasurement FunctionsTable 3-2 Effective Parameter Valuesa Number of units

Pagina 376

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 3-19Sampling MeasurementsMeasurement FunctionsLogarithmic Sampling Measurement Logarithmic sampling

Pagina 377 - To Measure Low Resistance

3-20 Agilent 4155C/4156C User’s Guide Vol.2, Edition 6Sampling MeasurementsMeasurement Functions@TIME Value@TIME value of measurement data is determin

Pagina 378

Agilent 4155C/4156C User’s Guide Vol.2, Edition 6 3-21Sampling MeasurementsMeasurement FunctionsRule to determine @TIME:@TIME value is determined by t

Comentarios a estos manuales

Sin comentarios