5
Technical Information
Message Mapping
Output Buffer Structure (for each
Controller Configured on the RS-485 Network)
Total buffer length: 4 bytes
Tab. 2
TSP – CONTROLLER ADDR-1
Offset
Byte
Size
Byte
Unit
Res
Range Description
COM
Serial
0 1
- 0-1 B0
Power Output ON/OFF
G
0 = off
1 = on
B1
Recover
R
0 = auto
1 = manual
B2 A
Autostart
0 = yes, 1= no
B3
B4 – B5
Controller operating mode
0 =manual
1 = automatic
M
2 = remote
3 = automatic/remote
B6 – B7
Active filament
0 = Mini Ti Ball
1 = TSP filament 1
2 = TSP filament 2
3 = TSP filament 3
F
1 2
1bit = 0.1A 300-500 Sublimation current N