E5810B User’s Guide 95
Troubleshooting the E5810B 4
Checking PC Client Connection
Checking the Syslog messages
The Syslog messages can be viewed by typing <E5810B IP
address>/systemLog.htm on your Web browser, where
<E5810B IP address> is the IP address of the E5810B.
For example, if the IP address of the E5810B is
169.254.58.10, type
http://169.254.58.10/systemLog.htm to display the
message table.
The Syslog file messages can also be viewed via the Telnet
Syslog- display command (refer to
Appendix A, “Using the
Telnet Utility). A typical display (with time from power- on
in parentheses) is shown in Figure 4- 2.
Figure 4-2 Typical Syslog display