User Manual: Family of 10-bit Digitizers ZM020170B Rev.D
XZ060
AGILENT ACQIRIS
U
SER MANUAL
FAMILY OF
10-
BIT DIGITIZERS
For Use with DC Series Digitizers
Models covered:
DC122 / DC152
DC222 / DC252 / DC282
Vista de pagina 0
1 2 3 4 5 6 ... 54 55

Indice de contenidos

Pagina 1 - BIT DIGITIZERS

User Manual: Family of 10-bit Digitizers ZM020170B Rev.D XZ060 AGILENT ACQIRIS USER MANUAL FAMILY OF 10-BIT DIGITIZERS For Use with DC Seri

Pagina 2

The PCI-8570/PXI-8570 User's Manual (Rev. 1.00) section 2.4 contains the software installation instructions. These should be executed before all

Pagina 3

2.2.3. Installation Before installing the Acqiris hardware, you should complete the following steps to install the software for Windows 2000/XP. NOT

Pagina 4

3. To proceed with the installation click “Next”. The following screen will be shown. 4. Please enter your user information and click “Next” to co

Pagina 5 - 1. Out of the Box

6. The screen above will normally allow the documentation to be installed. Remove the check from the box if you do not want online access to the man

Pagina 6 - 1.7. Warranty

8. The screen below asks for the desired installation type. After having made your choice Click “Next” to continue. 9. If you chose the Custom inst

Pagina 7 - 1.9. System Requirements

12. Furthermore, you should give a name to the shortcut folder. This is the menu entry under Start → Programs where you will find the shortcuts for

Pagina 8 - 1.12. Cleaning

14. AcqirisLive needs the LabWindows/CVI 7.0 Run-Time Engine to run. If Setup has detected that a LabWindows/CVI Run-Time Engine is already installe

Pagina 9 - 2. Installation

16. A summary will be shown to allow you to check what you have asked for 17. You are now ready to install. You may still go back to any previous

Pagina 10 - 2.2.2. Multiple Versions

18. Setup will now copy the files and make the necessary changes to your system. When done, an information screen will be displayed. Please read thi

Pagina 11 - 2.2.3. Installation

20. Setup will prepare a registration e-mail in your e-mail client application upon termination of the setup procedure. You can then decide whether

Pagina 12

June 2007 The information in this document is subject to change without notice and may not be construed in any way as a commitment by Agilent Techno

Pagina 13

21. Click “Finish”. The software installation is now complete. 22. You can now either accept the suggestion to restart the computer or you should s

Pagina 14

 Debian Sarge 3.1 2.6.8-3-686,  Debian 4.0 etch Kernel version 2.6.18-4-686,  Scientific Linux 4.4 Kernel version 2.6.9-11.EL) The following t

Pagina 15

 make clean to remove all *.o files in AcqirisLinux/linuxdriverpci.  make to generate a new kernel mode driver acqrsPCI.o and also copy it to the

Pagina 16

2.4. Installing the Hardware 1. Turn off the power of the PC and the crate in the case of a CompactPCI module. For PCI modules the PC should be unpl

Pagina 17 - “Install” when ready

To proceed with the installation click "No, not this time" and then “Next”. The following window will appear: To proceed with the instal

Pagina 18

and then NOTE: In some systems an application program (such as AcqirisLive) will not yet work correctly at this point. One additional boot cycle ma

Pagina 19

2.6. LabVIEW RT During program development you can choose whether you use LabVIEW or LabVIEW RT compatible libraries by switching the version present

Pagina 20

3. Product Description 3.1. Overview DEMUX256K Acq MemPCI Interface 10- bit SH + ADCTIMEBASETRIGGERcircuit CardControllerThr DAC Input Signal Ampli

Pagina 21

3.2. Channel Input The 10-bit digitizer family can be configured with a variety of front-end mezzanine boards offering different capabilities. The cu

Pagina 22 - 2.3.2. Special cases

3.2.5. Bandwidth and Rise Time The bandwidth specification indicates the frequency at which an input signal will be attenuated by 3 dB (approximately

Pagina 23 - 2.5.2. Windows XP

CONTENTS 1. OUT OF THE BOX...

Pagina 24

3.3. Data Acquisition The table below summarizes the characteristics discussed in the sections that follow: Model Agilent # Max. Sampling Rate Ma

Pagina 25

The Single Acquisition mode is the normal operation of most digitizer products. In this mode an acquisition consists of a waveform recorded with a sin

Pagina 26 - 2.6. LabVIEW RT

This cannot be done in larger crates such as the Acqiris CC121. The actual transfer speed obtainable will depend on many other system characteristics.

Pagina 27 - Simplified Block Diagram

3.4.8. Pre- and Post-Trigger Delay To increase trigger flexibility a pre- or post-trigger delay can be applied to the trigger position. The amount o

Pagina 28 - 3.2.4. Mezzanine Front-end

A full internal calibration of a digitizer can be very time consuming (> 100 s/digitizer), in particular for the HZ models. Therefore, several othe

Pagina 29 - 3.2.9. Using Probes

NOTE: The External Trigger Output functionality is implemented in the hardware. No Trigger Out signal occurs for software-generated triggers such as t

Pagina 30 - 3.3.2. Acquisition Memory

Crate DC1x2 all models DC2x2 Default Memory DC2x2 Optional Memory CC103 / CC105 None None None CC108 normal and low power None 4 4 CC108-600 None

Pagina 31 - 3.3.8. Data Readout

Complies with EN61326-1: Industrial Environment EMC Emissions Complies with EN61326-1: Class A for radiated emissions Required Airflow > 2 m/s in s

Pagina 32

4. Running the AcqirisLive Application AcqirisLive is an application to control and demonstrate the capabilities of Acqiris Digitizers on a single ma

Pagina 33 - 3.6. Internal Calibration

4.2. Control Panel and Functions 4.2.1. Control Panel Mode In AcqirisLive there are two control panel modes available, Oscilloscope Mode and Trans

Pagina 34 - 3.7. ASBus

3.4.3. Trigger Level... 32 3.4.4. Edg

Pagina 35 - Trigger Out

Oscilloscope Mode Transient Recorder Mode 4.2.2. Displaying Multiple Traces If multi-channel modules, or several si

Pagina 36

As an alternative to controlling the channels to be displayed from the control panel you can also control them by selecting the desired channels from

Pagina 37 - Required Airflow

1. Clicking on the white numeric display of the voltage scale will show a pop-up list. Select the desired gain setting with the mouse pointer. 2. C

Pagina 38

discussion, a valid trigger indicates a trigger signal meeting the trigger conditions at a time when the digitizer is armed and ready to acquire data.

Pagina 39 - 4.2.1. Control Panel Mode

• Make sure the maximum number of samples (MAX samples in Memory panel) is large enough. • Select the desired time per division setting (timebase pa

Pagina 40 -

image below. To clear the display in persistence display mode, press the “Clear” button that appears on the main display window. 4.3. Top Line Menu o

Pagina 41 - 4.2.4. Keyboard shortcuts

Selecting the “Write files at end option” acquires all waveforms into memory first, before converting to the selected format and writing the data to d

Pagina 42 - 4.2.7. Acquisition Mode

waveform display window. The time window displayed can be manipulated by allocating more or less memory to the acquisition. The External 10 MHz Refere

Pagina 43 - 4.2.8. Timebase and Memory

-l low priority process -m medium priority process -n no DMA for data transfers -p Use acquisition polling -r start in Transient Recorder (digitizer

Pagina 44 - 4.2.10. Segmented Memory

When the program checks for an event from the operating system (e.g. to react to user input), it can put itself to sleep for a specified period of tim

Pagina 45 - Waveforms

1. Out of the Box 1.1. Message to the User Congratulations on having purchased an Agilent Technologies Acqiris data conversion product. Acqiris Digi

Pagina 46 - 4.7. Combine channels

5. Running the GeoMapper Application 5.1. Who needs a Geographical Map of Modules The GeoMapper application gives the user the possibility of tellin

Pagina 47 - Available Switches

Selecting a row will cause all of the LED's of modules in that Bus to be turned on RED. This should make it easy to identify which crate the mod

Pagina 48

The GeoMapper application will always work with the standard AqGeo.map file. If you need to have several such files corresponding to different configu

Pagina 49

6. Appendix A: ASBus2 for CompactPCI/PXI Digitizers Specification and User Instructions User Manual: Family of 10-bit Digitizers Page 53 of 55

Pagina 50 - 5.3. How to run GeoMapper

7. Appendix B: XA001 Battery Backup for CompactPCI Digitizers Specification and Assembly Instructions User Manual: Family of 10-bit Digitizers Pa

Pagina 51

8. Appendix C: XA100 BNC Input Overvoltage Protection Specifications and User Instructions User Manual: Family of 10-bit Digitizers Page 55 of 55

Pagina 52

CAUTION: Do not exceed the maximum input voltage rating! The maximum input voltage for 50 Ω input impedance is ±5 V. The maximum input for 1 MΩ in

Pagina 53 - 6. Appendix A: ASBus

In exercising this warranty, Agilent Technologies will repair or replace any product returned to the Agilent service center, within the warranty perio

Pagina 54

1.10. Transport & Shipping CAUTION: Cards can be safely transported in their original shipping packages. DC cards can be transported when proper

Pagina 55

2. Installation This chapter describes how to install the Acqiris hardware and software for Windows 2000/XP, Linux, National Instruments LabVIEW RT,