Agilent Technologies Cell Phone S GSM Manual de usuario Pagina 205

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 381
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 204
4-99
Screens
Pwr Ramp, Fall Edge
Pwr Ramp, Fall Edge
NOTE When multiburst is turned on, display update rate for power versus time and phase
traces will be slowed down while multiple bursts are collected.
This view displays the falling portion of the amplitude envelope with the amplitude
mask superimposed. The vertical range is 40 to +5 dBm. The horizontal range is
+144 to +156 or +84 to +96 bit periods depending on the burst type.
1. Amplitude This is a copy of the RF analyzer Amplitude field. This is the amplitude to be
assumed at the selected input port.
Range RF IN/OUT: 27.9 to +41.0 dBm. AUX RF IN: 58.0 to +20.0
dBm.
See Also Screens: RF Generator/RF Analyzer (RF Analyzer) Chapter 3:
Specifications
2. Marker These fields display the time and level at the current marker position.
Vista de pagina 204
1 2 ... 200 201 202 203 204 205 206 207 208 209 210 ... 380 381

Comentarios a estos manuales

Sin comentarios