Agilent Technologies 8568B Especificaciones Pagina 1

Busca en linea o descarga Especificaciones para Multímetros Agilent Technologies 8568B. Agilent Technologies 8568B Specifications Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 24
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Agilent
8568B RF Spectrum Analyzer
100 Hz to 1.5 GHz
Technical Specifications
Exceptional RF performance
Measurement aids
Easy-to-use front panel
“On-board” computing capability
Power signal and trace processing functions
Decision-making capability
Distributed processing with a computer
Direct plotter output
Stores and executes custom measurement routines
Vista de pagina 0
1 2 3 4 5 6 ... 23 24

Indice de contenidos

Pagina 1 - 100 Hz to 1.5 GHz

Agilent8568B RF Spectrum Analyzer100 Hz to 1.5 GHzTechnical Specifications• Exceptional RF performance• Measurement aids• Easy-to-use front panel• “On

Pagina 2

10Trace functionsYou can easily manipulate the way trace information is processed and displayedby the 8568B. Using commands MPY (Multiply) and COMPRES

Pagina 3 - Make Precise Measurements

11Get Results, Mot Just Data, Using High-Level Signal and Trace Processing ToolsThe built-in, high-level functions of the 8568B provide signal and tra

Pagina 4 - Single sideband phase noise

12Create "On-Board" Measurement RoutinesSoftkey programming lets you develop the analyzer's measurement “personality” by allowing you t

Pagina 5 - Get Acquainted Fast

13Combine Processing Tools and Softkeys to Solve Complex Measurement TasksHere are a few examples of measurements that can be be performed by programs

Pagina 6 - Front panel softkeys

14The 8568B + PC = unparalleled measurement capabilityCombine softkey routines with systemsoftware to save I/O time and give youthe power of distribut

Pagina 7 - Basic operation

15• The ideal EMI diagnostic tool• Measurement software for fully automated EMI testing• The Agilent 85685A RF preselector converts the Agilent 8568B/

Pagina 8 - Marker-aided measurements

16FrequencyMeasurement range100 Hz to 1500 MHz dc coupled and 100 kHz to 1500 MHz ac coupled.Resolution3 dB bandwidths of 10 Hz to 3 MHz in a 1, 3, 10

Pagina 9 - Simplify Your Signal Analysis

17Bandwidth selectivity60 dB/3 dB bandwidth ratio:< 15:1 3 MHz to 100 kHz< 13:1 30 kHz to 10 kHz< 11:1 3 kHz to 30 Hz60 dB points on 10 Hz ba

Pagina 10 - Trace functions

18See definition of specifications and supplemental characteristics on page 16.The marker must be positioned at least 20 dB above the noise or the int

Pagina 11 - Amplitude modulation analysis

19Reference linesAccuracyEquals the sum of reference level accuracy plus the scale fidelity between the reference level and reference line.Dynamic ran

Pagina 13 - Harmonic distortion

20SpecificationsSee definition of specifications and supplemental characteristics on page 16.SweepSweep timeContinuousSequential sweeps initiated by t

Pagina 14 - Automatic Test System

21In log scales, the IF output is logarithmically related to the RF input signal; in linear, the output is linearly related. The output is nominally –

Pagina 15 - EMI Measurement Capability

22Remote operationThe standard 8568B operates on the interface bus (GP-IB). All analyzer control settings (with the exception of VIDEO TRIGGER LEVEL,

Pagina 17

24Iwww.agilent.com/find/emailupdatesGet the latest information on the productsand applications you select.Agilent Technologies’ Test and Measurement S

Pagina 18

3Measurement accuracyHigh repeatability and features suchas tunable marker with frequencycount allow measurements to be mademore accurately and conven

Pagina 19

4Resolution bandwidth10 Hz to 3 MHz resolution bandwidthsare used in a 1, 3, 10 sequence. Anappropriate bandwidth is alwaysavailable to provide proper

Pagina 20

5Numeric/unit keypadA numeric/unit keypad allows precise entry of a function when aspecific setting is desired.For example:To increase the center freq

Pagina 21

6Front panel softkeysMake your own front panel functions by defining softkeys, up to 58 charactersin length, directly from the front panel. Any analyz

Pagina 22

7Complete Your Measurements Quickly and EasilyOperator-oriented featuresIt’s easy to operate the 8568B. It takes only a few functions to make a basics

Pagina 23

8Direct plotter outputAll trace, graticule, and annotationinformation displayed on the CRTcan be plotted without the aid of acontroller. Simply connec

Pagina 24 - 5952-9394

9Peak search and signal trackZoom in quickly to the highestamplitude response displayed on the CRT using the functions [PEAKSEARCH] and [SIGNAL TRACK]

Comentarios a estos manuales