Types of probes (continued)
Current probes
Current probes sense the current flow-
ing through a conductor and convert
it to a voltage that can be viewed and
measured on an oscilloscope. Agilent
current probes use a hybrid technology
that includes a Hall-effect sensor,
which senses the DC current, and a
current transformer, which senses the
AC current. Using split core construc-
tion, the current probe easily clips
on and off of a conductor, making it
unnecessary to make an electrical con-
nection to the circuit. Measurement
bandwidths from DC to 100 MHz are
available.
Current probe characteristics
Model Probe type Probe bandwidth Max input current Applications and use
Oscilloscope
compatibility
1
1146A AC/DC current,
0.1 V/A
(0-10 A peak)
or 0.01 V/A
(0-100 A peak)
100 kHz 100 A peak AC line, motors,
automotive current
measurement
Requires 9-Vdc battery
High-impedance BNC input
1147B
3
AC/DC current,
0.1 V/A
50 MHz 15 A peak
continuous, 30 A
peak non-continuous
Motors, switching power
supplies, magnetic-device
current measurements
High-impedance AutoProbe
input
N2893A
3
AC/DC current
0.1 V/A
100 MHz 15 A peak
continuous,
30 A peak
non-continuous
Motor, switching power
supplies, magnetic device
current measurements
High-impedance AutoProbe
input
N2780B
2
AC/DC current,
0.01 V/A
2 MHz 500 Arms continuous
700 A peak
non-continuous
Motors, switching power
supplies, line currents
High-impedance BNC input
N2781B
2
AC/DC current,
0.01 V/A
10 MHz 150 Arms continuous
300 A peak
non-continuous
Motors, switching power
supplies, transformers
High-impedance BNC input
N2782B
2
AC/DC current,
0.1 V/A
50 MHz 30 Arms continuous
50 A peak
non-continuous
Switching power supplies,
amplifiers, magnetic
devices
High-impedance BNC input
N2783L
2
AC/DC current
0.1V/A,
5 m cable
80 MHz 30 Arms continuous
50 A peak
non-continuous
Automotive device
measurement
High-impedance BNC input
N2783B
2
AC/DC current,
0.1 V/A
100 MHz 30 Arms continuous
50 A peak
non-continuous
Switching power
supplies, low current
measurements
High-impedance BNC input
1 To use the 1146A or N2780B Series current probe with Infiniium 80000, 90000, or 5485xA Series scope, order E2697A 1-MΩ high-impedance adapter.
2 Requires N2779A 3-channel power supply.
3 Compatible with 3000X, 5000, 6000 (300MHz-1GHz), 7000, 9000, 90000X/Q Series only. Use N5449A for use with 90000X/Q.