RF SafetyEMF measurementand simulation toolsEMF_01_11_v2.indd 1EMF_01_11_v2.indd 1 20/01/11 13:16:0120/01/11 13:16:01

Pagina 2 - © SATIMO 2010

8• Operational frequency band up to 6 GHz• Detection threshold down to 0.005 V/m• Compact and light-weight• Faster downloading process*• Better IP r

Pagina 3 - What are reference levels?

9General Public - EME Spy 140EME Spy Analysis main window➊ Technical characteristicsFREQUENCY RANGES AXIAL ISOTROPY Min - Max Standard devia

Pagina 4

10 Optional  Included➊ Product category• E-fi eld frequency selective personal exposure meter ➋ Measurement capabilities• Continuously monitors pers

Pagina 5 - Occupational

11General public - EME Spy 121/100Thanks to its dedicated software, EME Spy Analysis, the dosimeter is easy to program. When the measurement cycle has

Pagina 6 - EME Guard

12Technical characteristics 88 MHz - 2.17 GHzEME SPY 100 FREQUENCY RANGES AXIAL ISOTROPYFM 88 MHz > 108 MHz ± 1.3 dBTV7 177 MHz > 213

Pagina 7 - A user friendly and fl exible

13General public - INSITE Box Optional  Included } Required➊ Product category• Remotely-operated E-field frequency selective monitoring station

Pagina 8 - A robust product

14Monitor exposure level within a geographical area and publish results on website The INSITE Box is connected to a website or PC through a FTP site.

Pagina 9 - General Public

15General public - INSITE Box➋ Detection levels Included Optional « Product features »Sensitivity 0.05 V/m Down to 0.005 V/mDynamic 40 dB (up to

Pagina 10 - EME Spy 140

16➊ Product category• E-field narrow band measurement system with spectrum analyzer ➋ Measurement capabilities• Performs in situ spot measurements➌ Us

Pagina 11 - General Public - EME Spy 140

17 Optional  Included } Required>Software:  INSITE Free on CD Rom with dongle key  INSITE Free/ANFR on CD Rom with dongle key>Equi

Pagina 12 - EME Spy 121/100

© SATIMO 2010Product specifi cations and descriptions in this document are subject to change without notice.Actual products may differ in appearance fr

Pagina 13

18Measurement scenarios can be defi ned by the user to fi t specifi c requirements ➊ INSITE Free SW is a fl exible tool that can be confi gured by the u

Pagina 14 - Mechanical characteristics

19high performance isotropic probes to cover the 100 KHz to 6 GHz frequency rangesTwo probes are available: from 100 KHz to 3 GHz and from 700 MHz to

Pagina 15 - INSITE Box

20100 KHz - 3 GHz probe antenna factor100 KHz - 3 GHz probe sensitivity without amplifi er100 KHz - 3 GHz Axial Isotropy with horizontal polarization10

Pagina 16 - Technical characteristics

21General public - INSITE Free700 MHz - 6 GHz probe antenna factor Axial Isotropy 3.6 GHz700 MHz - 6 GHz probe sensitivity➊ Mechanical characteristics

Pagina 17 - Detection levels

22Perform isotropic measurements without changing the position of the probeINSITE Free System performs a measurement for each axis and over all predefi

Pagina 18 - INSITE Free

23General public - INSITE Free➍ Hardware requirementsComputer PC Pentium 500 MHzCable link* 3 USB PortOperating system Windows 98/2000/XP/7Memory

Pagina 19 - >Services:

24Simulationsoftware>EMF_01_11_v2.indd Sec1:24EMF_01_11_v2.indd Sec1:24 20/01/11 13:16:1420/01/11 13:16:14

Pagina 20 - Measurement scenarios can be

 Optional  Included➊ Product category• Electromagnetic exposure simulation software ➋ Simulation capabilities• EMF Visual is a prediction, analysis

Pagina 21 - General public - INSITE Free

26Cote2emf module: build & export 3D scenes from 2D map images or GIS fi les. • Defi nition of building and ground fl oor outlines with graphic tool

Pagina 22

27Simulation software - EMF Visual• Advanced texture mapping of faces from a bitmap image.STEP 2: Antenna selection and installation.The EMF Visual s

Pagina 23

1The continuous growth of wireless communication has in the recent past raised public awareness and concerns about the potential health hazards due to

Pagina 24 - Switch box characteristics

28STEP 3: Computation.After defi ning the computation volume around the area of interest, the electromagnetic fi eld level calculation is launched. The

Pagina 25

29Simulation software - EMF Visual• Selection of the active antennas and adjustment of the input power of antennas to analyse co-sitting interactio

Pagina 26 - Simulation

About SATIMOSATIMO specializes in the design and manufacture of electromagnetic fi eld measu-rement systems in the microwave frequency range. For over

Pagina 27 - EMF Visual

2measurement standards and protocolsThe basic restrictions and reference levels defi ned by the ICNIRP are guidelines, which have been used as a basis

Pagina 28

Occupationalsafety>EMF_01_11_v2.indd Sec1:3EMF_01_11_v2.indd Sec1:3 20/01/11 13:16:0420/01/11 13:16:04

Pagina 29

4➊ Product category• Broadband personal exposure meter➋ Measurement capabilities• Continuously records the electromagnetic fi eld level and alerts us

Pagina 30 - Horizontal cut plane

5Occupational safety - EME GuardA user friendly and fl exible instrument The EME Guard Analysis software defi nes two user profi les:➊ Administrator mode

Pagina 31

6A robust product The device is equipped with an auto-test system which is launched when the device is switched on. This test ensures that the EME Gua