Agilent E8462A Relay Multiplexer Command Reference 73
Parameters
Comments Related Commands: INITiate[:IMMediate]
Example Query Number of Scans
This example sets a multiplexer module for 10 scanning cycles and queries the
number of scan cycles set. The
ARM:COUN? command returns 10.
ARM:COUN 10
Set 10 scans per INIT command.
ARM:COUN?
Query number of scans.
Parameter
Name
Parameter
Type Range of Values
Default
Value
MIN|MAX numeric MIN=1, MAX=32,767 current
cycles