Chapter 5 61
Remote operation
HSCSD Subsystem GPIB Commands
HSCSd:SLAVe:UPLink:AMPLitude:CONTrol
Description This defines the relationship between the slave Tx level, and the slave
expected uplink amplitude. MS TX LEV indicates that setting the slave’s
Tx level also sets the slave’sexpected uplink amplitude.MANUAL indicates
that setting the slave’s expected uplink amplitude is independent from
the value of the slave’s Tx level.
Note that in standard mode, setting either the slave Tx level, or the slave
expected uplink amplitude, forces the value of the slave amplitude
control to MS TX LEV or MANUAL respectively.
Syntax HSCSd:SLAVe:UPLink:AMPLitude:CONTrol
HSCSd:SLAVe:UPLink:AMPLitude:CONTrol?
Command options ‘MS TX LEV’ | ‘MANUAL