Chapter 1: Agilent Technologies 16700A/B-Series Logic Analysis System
Using a Timing Analyzer and an Oscilloscope
The Format Tab
1. Select the Format tab and rename one label to Data.
2. Assign the bits that map to the input probe signals.
The Trigger Tab
1. Select the Trigger tab, then select the Trigger Functions tab.
2. Select the function Find anystate n times, then select Replace.
This will cause the Timing analyzer to trigger and begin running as soon as
the arming signal is received from the oscilloscope.