Agilent Technologies E8257C PSG Manual de usuario

Busca en linea o descarga Manual de usuario para Generadores De Poder Agilent Technologies E8257C PSG. Agilent E8247C/E8257C PSG CW and Analog Signal Generators Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 16
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Agilent E8247C/E8257C
PSG CW and Analog
Signal Generators
Data Sheet
All specifications and characteristics apply over a 0 to 55°C range
(unless otherwise stated) and apply after a 45 minute warm-up time.
Supplemental characteristics, denoted as typical or nominal, provide
additional (non-warranted) information.
Definitions
Specifications (spec): represent warranted performance.
Typical (typ): performance is not warranted. It applies at 25°C. A minimum of 80% of all
products meet typical performance.
Nominal (nom): values are not warranted. They represent the value of a parameter that is most likely
to occur; the expected or mean value. They are included to facilitate the application of the product.
Standard (std): No options are included when referring to the signal generator unless noted otherwise.
PSG Signal Generators
Option 520 Option 540
250 kHz to 20 GHz 250 kHz to 40 GHz
CW only E8247C E8247C
Analog E8257C E8257C
Vector E8267C
(See E8267C data sheet for PSG Vector Signal
Generator specifications)
Vista de pagina 0
1 2 3 4 5 6 ... 15 16

Indice de contenidos

Pagina 1 - Signal Generators

Agilent E8247C/E8257CPSG CW and Analog Signal GeneratorsData SheetAll specifications and characteristics apply over a 0 to 55°C range (unless otherwis

Pagina 2 - Table of Contents

101. For fc< 2 MHz AM is usable but not specified. AM specifications apply with ALC on, and envelope peaks < maximum specified power. For instru

Pagina 3 - Specifications

11Standard Standard Option 1E62> 3.2 GHz 500 MHz to 3.2 GHz 10 MHz to 3.2 GHzOn/off ratio 80 dB 80 dB (typical) 80 dBRise/fall times (Tr, Tf ) 10

Pagina 4 - (Option 007)

12Modes Free-run, triggered, triggered with delay, doublet, and gated. Triggered with delay, doublet, and gated require external trigger source.Perio

Pagina 5

13Interfaces GPIB (IEEE-488.2,1987) with listen and talk, RS-232,and 10BaseT LAN interface.Control languages SCPI version 1997.0. Also will emulate m

Pagina 6

14RF output Nominal output impedance 50 Ω.For 20 GHz models Precision APC-3.5 male, or Type-N with Option 1ED.For 40 GHz models Precision 2.4 mm male;

Pagina 7 - Spectral purity

15Stop sweep In/Out Open-collector, TTL-compatible input/output. In ramp sweep operation, provides low level (nominally 0 V) during sweep retrace and

Pagina 8

www.agadent.com/find/emailupdatesGet the latest information on the productsand applications you select.Agilent Email UpdatesAgilent Technologies’ Test

Pagina 9 - Phase modulation

2Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3Frequency . . . . . . . .

Pagina 10

3Range1Option 520 250 kHz to 20 GHzOption 540 250 kHz to 40 GHzResolutionCW 0.001 HzAll Sweep modes 0.01 Hz2Accuracy Aging rate ± temperature effect

Pagina 11 - (E8257C only)

4Digital sweepRamp (analog) sweep(Option 007)1Operating modes Step sweep of frequency or amplitude or both (start to stop)List sweep of frequency or a

Pagina 12 - Internal pulse generator

5Power1(dBm)Frequency range Standard Option 1EA20 GHz models250 kHz to 3.2 GHz –20 to +13 –20 to +16250 kHz to 3.2 GHz (with Option 1E6)2–20 to +13

Pagina 13 - General specifications

6Level accuracy with step attenuator1(dB)Frequency> +10 dBm +10 to –10 dBm –10 to –70 dBm –70 to –90 dBm –90 to –110 dBm250 kHz to 2 GHz±0.6 ±0.6 ±

Pagina 14 - Input/Output

7Harmonics1(dBc at +10 dBm or maximum specified output power, whichever is lower)< 1 MHz –28 dBc (typical)1 MHz to 2 GHz –28 dBc> 2 GHz to 20

Pagina 15 - Options, Accessories

8Option UNR: Enhanced SSB phase noise (CW)Offset from carrier (dBc/Hz)Frequency 100 Hz 1 kHz 10 kHz 100 kHzspec (typical) spec (typical) spec (ty

Pagina 16 - Related Agilent Literature

9Typical rms jitter:1Standard Carrier SONET/SDH rms jitter Unit intervals Time frequency data rates bandwidth (µUI) (fs)155 MHz 155 MB/s 100 Hz to