Performance characteristics (continued)
Vertical system (continued)
Range
1
2mV/divto5V/div(1MΩor50Ω)
Maximuminput Maximuminputvoltageforanaloginputs:
CATI300Vrms,400Vpk;transientovervoltage1.6kVpk
CATII100Vrms,400Vpk
withN2863A10:1probe:CATI600V,CATII300V(DC+peakAC)
with10073C10:1probe:CATI500Vpk,CATII400Vpk
with50Ωinput:5Vrms,CATI
Offsetrange ±5Vonranges<10mV/div;
±20Vonranges10mV/divto200mV/div;
±75Vonranges>200mV/div
Dynamicrange ±8div
Inputimpedance 1MΩ±1%||12pFor50Ω±1.0%,selectable
Coupling AC,DC
BWlimit 25MHzselectable
Channel-to-channelisolation DCtomaxbandwidth>40dB
Standardprobes DSO501xA:10:1N2863Ashippedstandardforeachoscilloscopechannel
DSO503xA:10:1N2863Ashippedstandardforeachoscilloscopechannel
DSO505xA:10:110073Cshippedstandardforeachoscilloscopechannel
ProbeID AutoprobesenseandAutoProbeinterface
Agilent-andTektronix-compatiblepassiveprobesense
ESDtolerance ±2kV
Noise,RMS,inputshorted DSO501xA:0.5%fullscaleor250µV,whicheverisgreater
DSO503xA:0.5%fullscaleor300µV,whicheverisgreater
DSO505xA:0.5%fullscaleor360µV,whicheverisgreater
DCverticalgainaccuracy
2
±2.0%fullscale
DCverticaloffsetaccuracy ≤200mV/div:±0.1div±2.0mV±0.5%offsetvalue;
>200mV/div:±0.1div±2.0mV±1.5%offsetvalue
Singlecursoraccuracy
1
±{DCverticalgainaccuracy+DCverticaloffsetaccuracy+0.2%fullscale(~1/2LSB)}
Example:for50mVsignal,oscilloscopesetto10mV/div(80mVfullscale),5mVoffset,
accuracy=±{2.0%(80mV)+0.1(10mV)+2.0mV+0.5%(5mV)+0.2%(80mV)}=±4.785mV
Dualcursoraccuracy
1
±{DCverticalgainaccuracy+0.4%fullscale(~1LSB)}
Example:for50mVsignal,oscilloscopesetto10mV/div(80mVfullscale),5mVoffset,
accuracy=±{2.0%(80mV)+0.4%(80mV)}=±1.92mV
1 2mV/divisamagnificationof4mV/divsetting.Forverticalaccuracycalculations,usefullscaleof32mVfor2mV/divsensitivitysetting.
2 Denoteswarrantedspecifications,allothersaretypical.Specificationsarevalidaftera30-minutewarm-upperiodand±10°Cfromfirmwarecalibrationtemperature.