Agilent Technologies 16800 Series Especificaciones Pagina 16

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 34
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 15
16
74AVC16244
10 K
65LVDS389
ENABLE
3.3
V
LVDS DATA OUT
3-STATE IN TTL
74AVC16244
74AVC16244
Pattern Generator Specifications and Characteristics
(16821A, 16822A, and 16823A) (continued)
Agilent 10473A 3-state 2.5-volt data pod
Output type 74AVC16244
3-state enable Negative true, 38 KΩ to GND,
enabled on no connect
Maximum clock 300 MHz
Skew
1
Typical < 1.5 ns; worst case = 2 ns
Recommended lead set Agilent 10498A
Agilent 10476A 3-state 1.8-volt data pod
Output type 74AVC16244
3-state enable Negative true, 38 KΩ to GND,
enabled on no connect
Maximum clock 300 MHz
Skew
1
Typical < 1.5 ns; worst case = 2 ns
Recommended lead set Agilent 10498A
Agilent 10483A 3-state 3.3-volt data pod
Output type 74AVC16244
3-state enable Negative true, 38 KΩ to GND,
enabled on no connect
Maximum clock 300 MHz
Skew
1
Typical < 1.5 ns; worst case = 2 ns
Recommended lead set Agilent 10498A
Agilent E8141A LVDS data pod
Output type 65LVDS389 (LVDS data lines)
10H125 (TTL non-3-state channel 7)
3-state enable Positive true TTL; no
connect=enabled
Maximum clock 300 MHz
Skew Typical < 1 ns; worst case = 2 ns
Recommended lead set E8142A
1. Typical skew measurements made at pod connector with
approximately 10 pF/50 KΩ load to GND; worst case skew
numbers are a calculation of worst case conditions through
circuits. Both numbers apply to any channel within the
pattern generator.
Vista de pagina 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 33 34

Comentarios a estos manuales

Sin comentarios