Agilent Technologies N2782B Especificaciones Pagina 1

Busca en linea o descarga Especificaciones para Multímetros Agilent Technologies N2782B. Agilent Technologies N2782B Specifications Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 26
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
To achieve the best results
from your scope, you
need the right probes
and accessories for your
particular application. That’s
why Agilent Technologies
offers a complete family
of innovative probes and
accessories for InfiniiVision
oscilloscopes. For the most
up-to-date and complete
information about Agilent’s
accessories, please visit our
Web site at:
www.agilent.com/find/probes
Table of Contents
Probe Compatibility Table ........................................................................2
Passive Probes ...........................................................................................4
High-voltage Passive Probes ...................................................................6
InfiniiMax Active Probes and Accessories ...........................................7
InfiniiMode Active Probes and Accessories ..........................................9
High-voltage Differential Active Probes .............................................. 11
Single-ended Active Probes .................................................................. 13
Mixed Signal Oscilloscope Logic Probes ............................................ 14
Clamp-on Current Probes ...................................................................... 16
High-Sensitivity Current Probes ........................................................... 18
Wedge Probe Adapters .......................................................................... 20
Miscellaneous Accessories .................................................................. 21
N2744A T2A Probe Interface Adapter ................................................. 23
Recommended Probes for Low-/Mid-Speed Bus Measurements .. 24
Agilent InfiniiVision Oscilloscope
Probes and Accessories
For 2000 X-, 3000 X-, 4000 X-, 6000 X-, 5000,
6000, and 7000 Series
Selection Guide Data Sheet
Vista de pagina 0
1 2 3 4 5 6 ... 25 26

Indice de contenidos

Pagina 1 - Probes and Accessories

To achieve the best results from your scope, you need the right probes and accessories for your particular application. That’s why Agilent Technologie

Pagina 2 - Probe Compatibility Table

10Characteristics and specifications for N2750A Series InfiniiMode probesModel number N2750A N2751A N2752AProbe bandwidth* (–3 dB) 1.5 GHz 3.5 GHz 6

Pagina 3

11High-voltage Differential Active Probes• 25 to 800 MHz bandwidth• Switchable attenuation• Measure up to 1,400 V CAT II and 7 kV CAT IN2790A/91A a

Pagina 4 - Passive Probes

12Ordering information for Agilent high voltage differential probes and power supply1141A 200-MHz differential probe1142A Probe control and power mod

Pagina 5 - Passive Probes (continued)

13Single-ended Active ProbesN2795A/96A/97A low-cost single-ended active voltage• High resistance (1M) and low capacitance (1 pF) input for low loadi

Pagina 6 - High-voltage Passive Probes

14Mixed Signal Oscilloscope Logic Probes• Compatible with all 40-pin logic probe• Flying leads offer flexibility and convenienceMSO probes offer gr

Pagina 7

15Mixed Signal Oscilloscope Logic Probes (continued)The InfiniiVision MSO digital channels were architected to be compatible with a wide variety of pr

Pagina 8 - Individual probe heads

16Clamp-on Current Probes• Up to 100 MHz bandwidth and 500 Arms current• Hybrid technology to measure ac and dc• Compatible with 1 M scope input

Pagina 9 - N2750A-52A InfiniiMode probe

17Characteristics of the 1146B current probeBandwidth* dc to 100 kHz (–3 dB)Current range*100 mV/A:100 mA to 10 A peak 10 mV/A:1 to 100 A peakOutput

Pagina 10 - < 3%

18High-Sensitivity Current Probes• Measure AC/DC currents as low as 50 uA• Ideal for capturing and analyzing low level current flow in the DUT t

Pagina 11 - 1141A 200 MHz differential

19High-Sensitivity Current Probes (continued)Probe characteristics and specificationBandwidth (–3 dB) Zoom-out channel: DC to 3 MHzZoom-in channel: DC

Pagina 12

2Probe Compatibility TableFor ordering information when replacing your probe or probe accessory: Refer directly to the page number listed in the table

Pagina 13 - Single-ended Active Probes

20Wedge Probe Adapters• Easy connection to surface mount ICs• Safe, with no chance of shorting• Mechanically non-invasive contact• 3-, 8-, and 16

Pagina 14 - MSO probes offer great value

21Miscellaneous AccessoriesTestmobile The sturdy Agilent 1180CZ Testmobile for use with 6000 Series oscilloscopes makes sharing your scope easy. Its l

Pagina 15

22Probe positioners• Easy-to-manipulate probe arms for hands-free browsing• One- or two-articulated arms with stable high-mass base (N2784A and N278

Pagina 16 - Clamp-on Current Probes

23N2744A T2A Probe Interface Adapter• Enables Tektronix® TekProbe-BNC® level 2 probes to connect to Agilent’s AutoProbe interface on InfiniiVision 30

Pagina 17

24Recommended Probes for Low-/Mid-Speed Bus MeasurementsApplications Speed and signal type Recommended probe Required probe bandwidthLIN 10 kHz, singl

Pagina 18

25Agilent Technologies OscilloscopesMultiple form factors from 20 MHz to > 90 GHz | Industry leading specs | Powerful applications

Pagina 19 - Ordering information

myAgilentmyAgilentwww.agilent.com/find/myagilentA personalized view into the information most relevant to you.www.axiestandard.orgAdvancedTCA® Extensi

Pagina 20 - Wedge Probe Adapters

31. The 1130A probe amplifier supports both single- and differential-ended measurements. Higher bandwidth InfiniiMax probe model 1131A, 1132A, and 1134

Pagina 21 - Miscellaneous Accessories

4• Designed for optimal performance with your Agilent InfiniiVision Series oscilloscopes• 1:1 and 10:1 attenuation• 20 to 500 MHzRugged, high-quali

Pagina 22 - Probe positioners

5Characteristics for Agilent passive probes10070D 10073D 10074D N2862B/63B N2889A N2890A N2873A/N2894ABandwidth 20 MHz 500 MHz 150 MHz 150 MHz/ 300

Pagina 23

6High-voltage Passive Probes• Ideal for measuring up to 30 kV• Up to 250 MHz bandwidth• 100:1 or 1000:1 attenuation10076B high-voltage probeThe Agi

Pagina 24

7InfiniiMax Active Probes and Accessories1130A-34A InfiniiMax high-performance active probe system• 1.5 - 7 GHz InfiniiMax probe system• InfiniiMax pr

Pagina 25

8InfiniiMax Active Probes and Accessories (continued)1130A-34A InfiniiMax high-performance active probe systemOrdering information for Agilent InfiniiMax

Pagina 26 - and TEK

9InfiniiMode Active Probes and AccessoriesN2750A-52A InfiniiMode probe• 1.5 - 6 GHz bandwidth• Dual attenuation ratio (2:1/10:1)• InfiniiMode probing

Comentarios a estos manuales

Sin comentarios