Certification options
Commercial calibration certificate with test data (Option UK6)
Complete set of measurements which tests unit to
manufacturer’s published specifications. Includes calibration
label, calibration certificate, and data report. Conforms to ISO 9001.
ISO 17025 compliant calibration (Option 1A7)
Complete set of measurements which tests unit to
manufacturer’s published specifications. Includes calibration
label, ISO 17025 calibration certificate, and data report,
measurement uncertainties and guardbands on all customer
specifications. Conforms to ISO 17025 and ISO 9001.
ANSI Z540 compliant calibration (Option A6J)
Complete set of measurements which tests unit to
manufacturer’s published specifications. Includes
pre- and post-adjustment data with measurement
uncertainty information compliant to the ANSI/NCSL
Z540 standard.
Warranty and service
1 and 3 year warranty and service plans are available at time of
instrument purchase. Standard warranty is 1 year.
Calibration
3 year calibration plans are available at time of instrument
purchase. Contact your local Agilent sales office for details.
Product services
Agilent product services provide tailored assistance related to a
specific need or application. Product services enable you to quickly
learn how Agilent instruments operate, their capabilities, and how
to apply that knowledge to achieve your specific measurement
goals. PNA series services available include:
Remote scheduled productivity assistance
1 Day of start-up assistance
Daily productivity assistance
PNA operator training for 8 students at your business site
PNA operator web classes for 1 student
Custom services to be qualified by an Agilent technical
consultant
E8361A/62B/63B/64B
Configuration Details
Selecting the correct mixer-test configuration:
Most mixer or converter test applications require Options 014, 080,
and 082 for conversion loss/gain, or Options 014, 080, 081 and
083 for conversion loss/gain and phase/delay measurements. If
you want to create and automate your own custom frequency-
offset measurements (for example, intermodulation distortion),
you may only need Options 014 and 080. For converters that
require input power below -27 dBm, or for devices that have a
large amount of LO feedthrough (like an unfiltered mixer), Option
UNL, which adds source attenuators, is highly recommended.
Besides allowing lower input power levels, these attenuators
improve the isolation between the PNAs internal source and
LO leakage signals, helping to prevent source-unleveled errors.
For devices that put out signals near or above the receiver’s
compression levels (which varies between –3 and +5 dBm,
depending on the model and frequency), Option 016 is recom-
mended, which adds receiver attenuators. Finally, Option 010,
which adds time-domain analysis, is very useful for gating out
unwanted, time-delayed responses which often occur when
measuring mixers.