Upgrade kits for the PNA-X N5242A
Upgrade kits are available to add options after initial purchase.
To order an upgrade kit for the PNA-X, order the analyzer’s model
number followed by a “U”, then indicate the option to be added
(example: N5242AU-010). The model and serial numbers of the
instrument to be retrofitted are required as part of the order.
Pulse measurements (Option H08)
User installable.
Time-domain (Option 010)
User installable.
Add IF inputs for antenna and millimeter-wave (Option 020)
User installable.
Add pulse modulator to internal 1
st
source (Option 021)
User installable.
Add pulse modulator to internal 2
nd
source (Option 022)
User installable. Option 224 or 400 required.
Add four internal pulse generators (Option 025)
User installable.
Frequency offset (Option 080)
User installable.
Scalar-calibrated converter measurements (Option 082)
User installable. Option 080 required, and can not be ordered
with Option 083.
Frequency converter measurements (Option 083)
User installable. Option 080 required, and can not be ordered
with Option 082.
Embedded LO measurements (Option 084)
User installable. Options 080 and 083 required. Requires
firmware A.07.50 and above.
Gain compression application (Option 086)
User installable. Requires firmware A.08.00 and above.
N-port capabilities (Option 551)
User installable.
Perpetual license for built-in performance test software for
Agilent inclusive calibration (Option 897)
User installable. Additional hardware required.
Perpetual license for built-in performance test software for
standards compliant calibration (Option 898)
User installable. Additional hardware required.
2 ports, extended power range and bias-tees (Option 921)
Applicable to 2-port model only (N5242A-200). This upgrade
adds one 65 dB source attenuator, one 35 dB receiver attenuator,
and one bias-tee to each test port. Includes installation at an
Agilent service center. Option 200 required.
2 ports, add an internal 2
nd
source, a combiner & mechanical
switches (Option 922)
Applicable to 2-port models only (N5242A-200, N5242A-219).
This upgrade adds an internal second source, a combiner and
mechanical switches. Access to the second source is available
through two output (SMA) connectors on the front panel.
Includes installation at an Agilent service center. Options 200,
219 and 080 required.
Fully corrected noise figure measurements, 2-port
(Option 924)
Adds fully-corrected noise figure measurements to 2-port
analyzer. Includes installation at an Agilent Service Center.
Option 219 or 224 required.
4 ports, extended power range and bias-tees (Option 926)
Applicable to 4-port model only (N5242A-400). This upgrade
adds one 65 dB source attenuator, one 35 dB receiver attenuator,
and one bias-tee to each test port. Includes installation at an
Agilent service center. Option 400 required.
4 ports, add an internal combiner & mechanical switches
(Option 927)
Applicable to 4-port models only (N5242A-400, N5242A-419).
This upgrade adds a combiner and mechanical switches.
Includes installation at an Agilent service center. Options 400,
419 and 080 required.
Fully corrected noise figure measurements, 4-port
(Option 929)
Adds fully-corrected noise figure measurements to 4-port
analyzer. Includes installation at an Agilent Service Center.
Option 419 or 423 required.
N5242A PNA-X upgrade path
2-port 4-port
200 219 224 400 419 423
921 922 926 927