Agilent Technologies 8753ET Guía de usuario Pagina 233

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 546
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 232
Chapter 1 1-219
Alphabetical Command Reference
SAVU
SAVU
Syntax
SAVU<ASCI|BINA>;
Description
Front Panel Equivalents
SCAL
Syntax
SCAL<num>; or SCAL?;
Description
Front Panel Equivalents
Command Description Range Query Response
SAVUASCI Selects ASCII format for saving to disk.
Conforms to CITIFile specifications.
N/A N/A
SAVUBINA Selects binary format for saving to disk. N/A N/A
Command Hardkey Softkey
SAVUASCI
SAVUBINA
Command Description Range Query Response
SCAL Sets the trace scale factor.
amplitude range
1
1. For log mag:
±
500 dB. For phase:
±
500 degrees. For Smith chart and Polar:
±
500 units. For linear magnitude:
±
500 units. For SWR:
±
500 units. The scale is always positive, and has minimum values of 0.001dB, 10e
12
degrees, 10e
15 seconds, and 10 picounits.
<num><
L
F
>
Command Hardkey Softkey
SCAL
Save/Recall
SAVE USING ASCII
Save/Recall
SAVE USING BINARY
Scale Ref
SCALE / DIV
Vista de pagina 232
1 2 ... 228 229 230 231 232 233 234 235 236 237 238 ... 545 546