12-14
Module I/O Specifications
A6 Signaling Source/Analyzer
Outputs
For levels and setting up signals for measuring,
see “A4 Modulation Distribution”, page 12-8.
To A4 Modulation Distribution Assembly
AFG1 J1(3), AFG2 J1(5)
Freq Range DC to 25 kHz
Freq Resolution 0.1 Hz
Freq Accuracy 0.01 % of setting
Output level (Max) 2.5 Vpk
Output Lvl Resolution 12 Bits (LSB = 5V/4096)
Output Lvl Acc (Uncal) ± 0.0183% F.S.
Output Channel Clock 838.8608 kHz
Output Impedance 1.336 k (680 pF Shunt )
THD+Noise (Sine) 0.10% (Output = 2.5 Vpk)
(Meas BW 80 kHz)
(20 Hz to 25 kHz)