133
OP value
You manually type in value here.
Mode
BSE
Range
16 Byte Hex in string format
Units
Hex
Preset
None
State Saved
Yes
Dependencies and/or Couplings Mode Setup > More > Security > Authentication Algorithm must be
set to MILENAGE.
Mode Setup > More > Security > Key Option must be set to OP.
Initial S/W Revision 6.0
Value is saved through a Preset ≥ 6.5.
Key Path
BSE > Mode Setup> More > Security
OPc value
You manually type in value here.
Mode
BSE
Range
16 Byte Hex in string format
Units
Hex
Preset
None
State Saved
Yes
Dependencies and/or Couplings Mode Setup > More > Security > Authentication Algorithm must be
set to MILENAGE.
Mode Setup > More > Security > Key Option must be set to OPc.
Initial S/W Revision 6.0
Value is saved through a Preset ≥ 6.5.
Key Path
BSE > Mode Setup> More > Security
AMF value
Authentication Management Field (AMF)
Refer to 3GPP 33.102.
Mode
BSE
Range
0000 to FFFF
Units
Hex
Preset
8000
State Saved
No
Initial S/W Revision
6.0
Key Path
BSE > Mode Setup> More > Security