49
PUSCH Target Power
Sets the target power in dBm for the physical uplink shared channel.
This power level is modified by the use of DCI 0 commands.
Mode
BSE
Range
-45 to +23
Preset
0.00 dBm
Dependencies and/or Couplings UE must be connected.
PUSCH Target Power and PUCCH Target Power cannot be
separated by more than 20 dB (PXT limitation). See further
clarification under “Closed Loop Power Control More
information” below. The PUSCH value always takes precedence
over the PUCCH value with regard to this separation in power
level.
Initial S/W Revision
6.4
Key Path
Mode > BSE > Func > UE Power Control > CLPC
PUCCH Target Power
Sets the target power in dBm for the physical uplink control channel.
Mode
BSE
Range
-45 to +23
Preset
0.00 dBm
Dependencies and/or Couplings UE must be connected.
PUSCH Target Power and PUCCH Target Power cannot be
separated by more than 20 dB (PXT limitation). See further
clarification under “Closed Loop Power Control More
information” below. The PUSCH value always takes precedence
over the PUCCH value with regard to this separation in power
level.