Using the U2000 Series with the N1918A Power Analysis Manager
The N1918A software is available in two versions: the basic Power Panel and advanced Power
Analyzer. Power Analyzer provides full access to the software’s complete features and capabilities
and its licenses, N1918A-100 and N1918A-200, are available for purchase separately. A free, fully
functional trial version of the Power Analyzer automatically runs for 30 days upon installation
from the bundled N1918A Power Analysis Manager CD. The table here shows functions accessible
with each version when used with the U2000 Series.
Display units:
Absolute: Watts or dBm
Relative: Percent or dB
Display resolution:
Resolution of 1.0, 0.1, 0.01 and 0.001 dB in log
mode; one to four digits in linear mode.
Default resolution:
0.01 dB in log mode; three digits in linear mode
Zero: For performing internal and external
zeroing.
Range: Sensor-dependent, configurable in
1-kHz steps.
Relative: Displays all successive
measurements relative to the last referenced
value.
Offset: Allows power measurements to be
offset by –100 dB to +100 dB, configurable in
0.001 dB increments, to compensate for
external loss or gain.
Duty cycle: Duty cycle values between 0.001%
to 99.999% can be entered in increments of
0.01% to display a pulse power representation
of measured power. The following equation is
used to calculate the displayed pulse power
value: Pulse Power = Measured Power/
Duty Cycle
Limits: High and low limits can be set in the
range between –150.00 dBm to +230.000 dBm,
in 0.001 dBm increments.
Preset default values: Channel Offset (dB) =
0, Duty Cycle Off, Frequency 50 MHz, AUTO
Average, AUTO Range, Free Run Mode,
dBm mode.
Measurement display functions
Soft panel (digital) display
Gauge (analog) display
Strip chart display
Multiple tabs
Multiple displays per tab
Multilist
(List view of multiple channels)
Graph functions
Single marker
Dual marker
Graph autoscaling
Graph zooming
Measurement math
Save/Load file functions
Save measurement data
(with timestamp)
Load measurement data
Data recording
(with timestamp)
Limit and alert functions
Limit and alert notifications
Alert summary
Instrument setting options
Save/Restore instrument
settings
Gate settings
FDO table parameters
Print option
Print application screen
Up to 2 displays
Power Panel (basic)
Power Analyzer (advanced)
Up to 2 markers per graph
Delta and ratio Delta and ratio
Applies to strip chart displays
Applies to strip chart displays;
up to 10,000 data points
Applies to soft panel, gauge
and strip chart displays; up
to 7 days
Applies to strip chart displays
Up to 5 sets of markers per
graph
Up to 10 markers per graph
Up to 3 displays
Enhanced with limit
and alert notifications
Enhanced with limit
and alert notifications
Applies to strip chart displays
For further details on the software, refer to “N1918A Power Analysis Manager Data Sheet”, literature
number 5989-6612EN.