Agilent Technologies N5990A-301PCI ExpressLink Training SuiteGetting Started Guide
5. Using the SoftwareConnecting To The InstrumentsOnce the software started, the main window and the connection dialog will appear as shown in Figure
8. Click the „Connect“ button9. If the connection was successful, the button „Apply and Close“ will be enabled, see Figure 410. Click the „Apply and C
Main User InterfaceAfter the successful connection to the instruments, the main window is displayed as given in Figure 5. This window is split into tw
HelpIn the “Help” menu (top right corner of the main window), you will find:• The "Getting Started Guide" (F1; this document)• The "Lan
Demo ModeWhen you close the connection dialog without connecting instruments, you enter the Demo Mode.The Demo Mode is intended for demostration purpo
When the de-emphasis signal converter is connected, or when the PCIExpress specification 3.0 is used, the current preset is also shown. The “Preset...
All other parameters reflect the standard sequence described in the CTS. Note that “Min. initial TS1 count” and “Min TS1 count before Loopback” are on
In the simplest case, a custom pattern file can be a text-file containing only hexadecimal data. Note that the binary data represented by this file mu
Error DetectorBy default, the J-BERT error detector compares all bits from the DUTwith the loopback pattern. With the option in the “Error Detector” g
By default, the generator uses an internal clock source, or an external clock multiplier (N4880A) for system board tests. Note that the N4880A must be
Notices© Agilent Technologies, Inc. 2013No part of this manual may be reproduced in any form or by any means (including electronic storage and retriev
Note that some jitter/SSC parameters will reset the sequencer when modified. This means that the current sequencer state is left and the link training
When the “Poll Sequence State” option in the “Options” menu is enabled, the current state of the sequencer is shown.When the sequence contains a loop
Saving And Loading SettingsYou can store your current settings using the “Apply and Save...” button in the main window, or via the main menu. Note tha
When the radio button “Generate From Parameters” is checked, the pattern will be automatically generated, i. e. the same way as in non-Expert Mode. Wh
To edit the script, click the “Edit Script” button. The script editor, as shown in Figure 19, will pop up. In the script editor, you can edit the sequ
6. TroubleshootingStartup FailsThe anti-virus software Sophos Endpoint Security might inadvertendly detect the PCIe Link Training Suite as a virus and
7. Switching to Version 1.1ScriptThe PCIe Link Training Suite v1.0 automatically inserted a pause at the beginning of the link training sequence. You
8. SupportIn case of persisting problems with the PCI Express Link Training Suite, please send a problem description to the PCI Express support node p
Technical Assistance: Contact CenterIf you need product assistance or if you have suggestions, contact theAgilent Technologies, Inc. Contact Center in
Contents1. INTRODUCTION...6PCI Express Link Tr
Startup Fails...
1. IntroductionPCI Express Link Training SuiteThe Agilent PCI Express Link Training Suite (N5990A-301) is a software tool which allows to train PCI Ex
2. Software Installation and UpdateThe PCI Express Link Training Suite N5990A-301 runs on a PC whichcontrols the J-BERT. If N5990A-301 is already inst
3. Starting and Registering the SoftwareStarting Registered SoftwareDouble click on the PCI Express Link Training Suite icon on the desktop or start t
4. SetupThere are several instruments which can be controlled by the PCIe Link Training Suite when properly connected:• An N4903B J-BERT is required◦