104 Agilent FrameScope 350 User’s Manual
4 Fiber Testing
Setting Up an Autotest
3 Press OK. The Fiber Autotest Settings screen displays.
Loss/Length Method
When Loss/Length Method is selected, the FrameScope 350
calculates the limit based on the length of the cable tested. You
can set values for connectors, loss per connector, splices, and
loss per splice. The connector and splice losses are added to the
loss that is calculated by multiplying the length of the fiber by
the loss/Km specification of the selected cable, which is shown
at the bottom of the Setup screen.
When you select Loss/Length Method and press Next on the
Loss Limit Setup screen, the screen changes to the following:
1 To set any of the variable values, press the variable. The numeric
keypad opens.
2 Press the backspace arrow to erase the displayed value, then enter
the new variable value. Press OK. The keypad closes.