Setting Up a Data Pattern Setting Up Generic and Advanced Signals
Agilent 81133A/81134A Pulse Generator User’s Guide, September 2008 41
6 Enable the Channel 1 normal Output:
By pressing the respective softkey in the user interface:
– OR –
By pressing the normal Out softkey for channel 1 next to the
Output port.
The Channel page now looks as follows:
Channel Settings for the
Pattern Signal
To set the channel parameters for channel 2:
1 Switch to Channel 2 by pressing the Ch2 softkey .
2 Switch to the Channel page.
3 Select the pattern mode Data.
4 Select the signal mode NRZ.
5 In the Levels panel, select the predefined level format ECL.
This automatically sets:
–the Amplitude to 800 mV
–the Offset to –1.350 V
–the Term. Voltage to2.0 V
Pattern Mode
PRBS
PRBS Polynome
Signal Mode
ECL Levels