Forming a Scanning
Multimeter
If multiplexers are used to form a scanning multimeter, they must be
assigned successive logical addresses beginning with the address
immediately following that of the multimeter. An example is shown in
Figure 2-2.
The scanning multimeter can consist of relay multiplexers, FET
multiplexers, or a combination of both. See “Connecting Multiplexers” on
page 30 for information on physically connecting the multiplexers to the
multimeter.
Figure 2-2. Setting Successive Logical Addresses to Form
an Instrument
Chapter 2 Configuring the HP E1326B/E1411B Multimeter 23