Agilent Technologies InfiniiVision 5000 Series Manual de servicio

Busca en linea o descarga Manual de servicio para Multímetros Agilent Technologies InfiniiVision 5000 Series. Agilent Technologies InfiniiVision 5000 Series Technical data Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 884
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Agilent InfiniiVision
5000 Series
Oscilloscopes
Programmer's Guide
Vista de pagina 0
1 2 3 4 5 6 ... 883 884

Indice de contenidos

Pagina 1 - Oscilloscopes

 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide

Pagina 2

10 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide :MARKer:MODE 276:MARKer:X1Position 277:MARKer:X1Y1source 278:MARKer:X2Posit

Pagina 3 - In This Book

100 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide4 Commands Quick Reference Table 32 :TRIGger:SPI Commands SummaryCommand Qu

Pagina 4

Commands Quick Reference 4Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 101 :TRIGger:TV:SOURce <source> (see page 568)

Pagina 5 - Contents

102 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide4 Commands Quick Reference :TRIGger:UART:PARity <parity> (see page 57

Pagina 6

Commands Quick Reference 4Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 103 Table 36 :WAVeform Commands SummaryCommand Query

Pagina 7

104 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide4 Commands Quick Reference n/a :WAVeform:PREamble? (see page 606)<preamb

Pagina 8

Commands Quick Reference 4Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 105 n/a :WAVeform:XORigin? (see page 620)<return_

Pagina 9

106 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide4 Commands Quick Reference Syntax Elements• "Number Format" on pa

Pagina 10

Commands Quick Reference 4Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 107 For example, <A> ::= <B> indicates t

Pagina 11

108 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide4 Commands Quick Reference #800001000<1000 bytes of data> <NL>8

Pagina 12

109 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5Commands by SubsystemSubsystem Description"Common (*) Commands"

Pagina 13

Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 11 :MEASure:VTIMe 332:MEASure:VTOP 333:MEASure:WINDow 334:MEASure:XMAX 335:MEA

Pagina 14

110 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem Command Types Three types of commands are used:• Co

Pagina 15

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 111 Common (*) CommandsCommands defined by IEEE 488.2 s

Pagina 16

112 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem n/a *OPT? (see page 123) <return_value> ::= 0

Pagina 17 - 6 Commands A-Z

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 113 Introduction toCommon (*)CommandsThe common command

Pagina 18 - 9 Status Reporting

114 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem selected and a common command is received by the in

Pagina 19 - 12 Programming Examples

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 115 *CLS (Clear Status) (see page 750)Command Syntax*CL

Pagina 20

116 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem *ESE (Standard Event Status Enable) (see page 750)C

Pagina 21 - What's New

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 117 Query Syntax *ESE?The *ESE? query returns the curre

Pagina 22 - 1 What's New

118 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem *ESR (Standard Event Status Register) (see page 750

Pagina 23

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 119 Return Format <status><NL><status>

Pagina 24

12 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide :SAVE Commands 377:SAVE:FILename 379:SAVE:IMAGe[:STARt] 380:SAVE:IMAGe:AREA

Pagina 25

120 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem *IDN (Identification Number) (see page 750)Query Sy

Pagina 26

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 121 *LRN (Learn Device Setup) (see page 750)Query Synta

Pagina 27

122 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem *OPC (Operation Complete) (see page 750)Command Syn

Pagina 28

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 123 *OPT (Option Identification) (see page 750)Query Sy

Pagina 29

124 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem *RCL (Recall) (see page 750)Command Syntax*RCL <

Pagina 30

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 125 *RST (Reset) (see page 750)Command Syntax*RSTThe *R

Pagina 31 - Obsolete

126 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem Display MenuDefinite persistence OffGrid 33%Vectors

Pagina 32

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 127 See Also • "Introduction to Common (*) Command

Pagina 33

128 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem *SAV (Save) (see page 750)Command Syntax*SAV <va

Pagina 34

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 129 *SRE (Service Request Enable) (see page 750)Command

Pagina 35

Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 13 :SYSTem:DATE 420:SYSTem:DSP 421:SYSTem:ERRor 422:SYSTem:LOCK 423:SYSTem:PRE

Pagina 36 - Version 4.00 at Introduction

130 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem Query Syntax *SRE?The *SRE? query returns the curre

Pagina 37 - Setting Up

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 131 *STB (Read Status Byte) (see page 750)Query Syntax*

Pagina 38 - 2 Setting Up

132 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem See Also • "Introduction to Common (*) Command

Pagina 39 - Using the LAN Interface

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 133 *TRG (Trigger) (see page 750)Command Syntax*TRGThe

Pagina 40 - Using the GPIB Interface

134 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem *TST (Self Test) (see page 750)Query Syntax*TST?The

Pagina 41 - Setting Up 2

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 135 *WAI (Wait To Continue) (see page 750)Command Synta

Pagina 42

136 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem Root (:) CommandsControl many of the basic function

Pagina 43 - Click Test Connection

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 137 :OPEE <n> (see page 159):OPEE? (see page 160)

Pagina 44

138 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem Introduction toRoot (:)CommandsRoot level commands

Pagina 45

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 139 :AER (Arm Event Register) (see page 750)Query Synta

Pagina 46

14 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide :TRIGger:DURation:QUALifier 468:TRIGger:DURation:RANGe 469:TRIGger:EBURst C

Pagina 47 - Getting Started

140 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :AUToscale (see page 750)Command Syntax:AUToscale:A

Pagina 48 - Capturing Data

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 141 • ":AUToscale:AMODE" on page 142Example

Pagina 49 - Analyzing Captured Data

142 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :AUToscale:AMODE (see page 750)Command Syntax:AUTos

Pagina 50 - Programming the Oscilloscope

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 143 :AUToscale:CHANnels (see page 750)Command Syntax:AU

Pagina 51

144 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :BLANk (see page 750)Command Syntax:BLANk [<sour

Pagina 52 - 3 Getting Started

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 145 :CDISplay (see page 750)Command Syntax:CDISplayThe

Pagina 53 - Getting Started 3

146 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :DIGitize (see page 750)Command Syntax:DIGitize [&l

Pagina 54 - Ensure New Data is Collected

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 147 ' because this is greater than the maximum sam

Pagina 55

148 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :HWEenable (Hardware Event Enable Register) (see pa

Pagina 56

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 149 • ":AER (Arm Event Register)" on page 139

Pagina 57

Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 15 :TRIGger:I2S:SOURce:WSELect 513:TRIGger:I2S:TRIGger 514:TRIGger:I2S:TWIDth

Pagina 58 - Checking Instrument Status

150 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :HWERegister:CONDition (Hardware Event Condition Re

Pagina 59 - Telnet Sockets

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 151 • ":OVLRegister (Overload Event Register)"

Pagina 60

152 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :HWERegister[:EVENt] (Hardware Event Event Register

Pagina 61 - Commands Quick Reference

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 153 • ":OVLRegister (Overload Event Register)"

Pagina 62 - Command Summary

154 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MERGe (see page 750)Command Syntax:MERGe <pixel

Pagina 63

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 155 :MTEenable (Mask Test Event Enable Register) (see p

Pagina 64

156 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem Return Format <value><NL><value>

Pagina 65

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 157 :MTERegister[:EVENt] (Mask Test Event Event Registe

Pagina 66

158 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem • ":OPEE (Operation Status Enable Register)&qu

Pagina 67

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 159 :OPEE (Operation Status Enable Register) (see page

Pagina 68

16 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide :TRIGger:SPI:PATTern:DATA 559:TRIGger:SPI:PATTern:WIDTh 560:TRIGger:SPI:SOU

Pagina 69

160 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem Query Syntax :OPEE?The :OPEE? query returns the cur

Pagina 70

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 161 :OPERegister:CONDition (Operation Status Condition

Pagina 71

162 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem Return Format <value><NL><value>

Pagina 72

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 163 :OPERegister[:EVENt] (Operation Status Event Regist

Pagina 73

164 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem Return Format <value><NL><value>

Pagina 74

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 165 :OVLenable (Overload Event Enable Register) (see pa

Pagina 75

166 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem Query Syntax :OVLenable?The :OVLenable query return

Pagina 76

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 167 :OVLRegister (Overload Event Register) (see page 75

Pagina 77

168 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem Return Format <value><NL><value>

Pagina 78

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 169 :PRINt (see page 750)Command Syntax:PRINt [<opti

Pagina 79

Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 17 :WAVeform:SOURce:SUBSource 615:WAVeform:TYPE 616:WAVeform:UNSigned 617:WAVe

Pagina 80

170 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :RUN (see page 750)Command Syntax:RUNThe :RUN comma

Pagina 81

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 171 :SERial (see page 750)Query Syntax:SERial?The :SERi

Pagina 82

172 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :SINGle (see page 750)Command Syntax:SINGleThe :SIN

Pagina 83

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 173 :STATus (see page 750)Query Syntax:STATus? <sour

Pagina 84

174 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :STOP (see page 750)Command Syntax:STOPThe :STOP co

Pagina 85

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 175 :TER (Trigger Event Register) (see page 750)Query S

Pagina 86

176 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :VIEW (see page 750)Command Syntax:VIEW <source&

Pagina 87

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 177 :ACQuire CommandsSet the parameters for acquiring a

Pagina 88

178 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem The :ACQuire:TYPE NORMal command sets the oscillosc

Pagina 89

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 179 :ACQuire:AALias (see page 750)Query Syntax:ACQuire:

Pagina 90

18 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide :MEASure:VSTArt 691:MEASure:VSTOp 692:MTESt:AMASk:{SAVE | STORe} 693:MTESt:

Pagina 91

180 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :ACQuire:COMPlete (see page 750)Command Syntax:ACQu

Pagina 92

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 181 :ACQuire:COUNt (see page 750)Command Syntax:ACQuire

Pagina 93

182 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :ACQuire:DAALias (see page 750)Command Syntax:ACQui

Pagina 94

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 183 :ACQuire:MODE (see page 750)Command Syntax:ACQuire:

Pagina 95

184 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :ACQuire:POINts (see page 750)Query Syntax:ACQuire:

Pagina 96

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 185 :ACQuire:SEGMented:ANALyze (see page 750)Command Sy

Pagina 97

186 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :ACQuire:SEGMented:COUNt (see page 750)Command Synt

Pagina 98

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 187 :ACQuire:SEGMented:INDex (see page 750)Command Synt

Pagina 99

188 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem Option ExplicitPublic myMgr As VisaComLib.ResourceM

Pagina 100 - 4 Commands Quick Reference

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 189 For lngI = lngSegments To 1 Step -1' Set the s

Pagina 101

Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 19 Status Reporting Decision Chart 73810 Synchronizing AcquisitionsSynchroniza

Pagina 102

190 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :ACQuire:SRATe (see page 750)Query Syntax:ACQuire:S

Pagina 103

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 191 :ACQuire:TYPE (see page 750)Command Syntax:ACQuire:

Pagina 104

192 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem See Also • "Introduction to :ACQuire Commands&

Pagina 105

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 193 :CALibrate CommandsUtility commands for viewing cal

Pagina 106 - Syntax Elements

194 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem • Starting the user calibration procedure.

Pagina 107 - Commands Quick Reference 4

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 195 :CALibrate:DATE (see page 750)Query Syntax:CALibrat

Pagina 108

196 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :CALibrate:LABel (see page 750)Command Syntax:CALib

Pagina 109 - Commands by Subsystem

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 197 :CALibrate:OUTPut (see page 750)Command Syntax:CALi

Pagina 110 - 5 Commands by Subsystem

198 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :CALibrate:STARt (see page 750)Command Syntax:CALib

Pagina 111 - Common (*) Commands

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 199 :CALibrate:STATus (see page 750)Query Syntax:CALibr

Pagina 112

Notices© Agilent Technologies, Inc. 2005-2010No part of this manual may be reproduced in any form or by any means (including electronic storage and re

Pagina 113

20 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide Index

Pagina 114

200 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :CALibrate:SWITch (see page 750)Query Syntax:CALibr

Pagina 115 - *CLS (Clear Status)

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 201 :CALibrate:TEMPerature (see page 750)Query Syntax:C

Pagina 116

202 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :CALibrate:TIME (see page 750)Query Syntax:CALibrat

Pagina 117

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 203 :CHANnel<n> CommandsControl all oscilloscope

Pagina 118

204 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem Introduction to:CHANnel<n>Commands<n>::

Pagina 119 - Commands by Subsystem 5

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 205 Reporting the SetupUse :CHANnel1?, :CHANnel2?, :CHA

Pagina 120 - *IDN (Identification Number)

206 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :CHANnel<n>:BWLimit (see page 750)Command Syn

Pagina 121 - *LRN (Learn Device Setup)

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 207 :CHANnel<n>:COUPling (see page 750)Command Sy

Pagina 122 - *OPC (Operation Complete)

208 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :CHANnel<n>:DISPlay (see page 750)Command Syn

Pagina 123 - *OPT (Option Identification)

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 209 :CHANnel<n>:IMPedance (see page 750)Command S

Pagina 124 - *RCL (Recall)

21 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide1What's NewWhat's New in Version 6.10 22What's New in Versi

Pagina 125 - *RST (Reset)

210 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :CHANnel<n>:INVert (see page 750)Command Synt

Pagina 126

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 211 :CHANnel<n>:LABel (see page 750)Command Synta

Pagina 127 - Example Code

212 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :CHANnel<n>:OFFSet (see page 750)Command Synt

Pagina 128 - *SAV (Save)

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 213 :CHANnel<n>:PROBe (see page 750)Command Synta

Pagina 129 - *SRE (Service Request Enable)

214 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :CHANnel<n>:PROBe:HEAD[:TYPE] (see page 750)C

Pagina 130

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 215 :CHANnel<n>:PROBe:ID (see page 750)Query Synt

Pagina 131 - *STB (Read Status Byte)

216 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :CHANnel<n>:PROBe:SKEW (see page 750)Command

Pagina 132

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 217 :CHANnel<n>:PROBe:STYPe (see page 750)Command

Pagina 133 - *TRG (Trigger)

218 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :CHANnel<n>:PROTection (see page 750)Command

Pagina 134 - *TST (Self Test)

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 219 :CHANnel<n>:RANGe (see page 750)Command Synta

Pagina 135 - *WAI (Wait To Continue)

22 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide1 What's New What's New in Version 6.10New features in version 6.1

Pagina 136 - Root (:) Commands

220 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :CHANnel<n>:SCALe (see page 750)Command Synta

Pagina 137

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 221 :CHANnel<n>:UNITs (see page 750)Command Synta

Pagina 138

222 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :CHANnel<n>:VERNier (see page 750)Command Syn

Pagina 139 - :AER (Arm Event Register)

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 223 :DISPlay CommandsControl how waveforms, graticule,

Pagina 140 - :AUToscale

224 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem • Set waveform persistence.• Specify labels.• Save

Pagina 141

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 225 :DISPlay:CLEar (see page 750)Command Syntax:DISPlay

Pagina 142 - :AUToscale:AMODE

226 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :DISPlay:DATA (see page 750)Command Syntax:DISPlay:

Pagina 143 - :AUToscale:CHANnels

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 227 Return Format <display data><NL><dis

Pagina 144

228 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :DISPlay:LABel (see page 750)Command Syntax:DISPlay

Pagina 145 - :CDISplay

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 229 :DISPlay:LABList (see page 750)Command Syntax:DISPl

Pagina 146 - :DIGitize

What's New 1Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 23 What's New in Version 6.00New features in version 6.0

Pagina 147

230 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :DISPlay:PERSistence (see page 750)Command Syntax:D

Pagina 148

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 231 :DISPlay:SOURce (see page 750)Command Syntax:DISPla

Pagina 149

232 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :DISPlay:VECTors (see page 750)Command Syntax:DISPl

Pagina 150

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 233 :EXTernal Trigger CommandsControl the input charact

Pagina 151

234 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem The following is a sample response from the :EXTern

Pagina 152

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 235 :EXTernal:BWLimit (see page 750)Command Syntax:EXTe

Pagina 153

236 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :EXTernal:IMPedance (see page 750)Command Syntax:EX

Pagina 154

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 237 :EXTernal:PROBe (see page 750)Command Syntax:EXTern

Pagina 155 - :MTEenable?

238 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :EXTernal:PROBe:ID (see page 750)Query Syntax:EXTer

Pagina 156

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 239 :EXTernal:PROBe:STYPe (see page 750)Command Syntax:

Pagina 157 - <value><NL>

24 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide1 What's New DiscontinuedCommands:WAVeform:POINts (see page 604) In the

Pagina 158

240 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :EXTernal:PROTection (see page 750)Command Syntax:E

Pagina 159 - :OPEE <mask>

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 241 :EXTernal:RANGe (see page 750)Command Syntax:EXTern

Pagina 160

242 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :EXTernal:UNITs (see page 750)Command Syntax:EXTern

Pagina 161 - Query Syntax

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 243 :FUNCtion CommandsControl functions in the measurem

Pagina 162

244 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :FUNCtion:RANGe <range> (see page 253):FUNCti

Pagina 163

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 245 Introduction to:FUNCtionCommandsThe FUNCtion subsys

Pagina 164

246 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :FUNCtion:CENTer (see page 750)Command Syntax:FUNCt

Pagina 165

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 247 :FUNCtion:DISPlay (see page 750)Command Syntax:FUNC

Pagina 166

248 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :FUNCtion:GOFT:OPERation (see page 750)Command Synt

Pagina 167 - :OVLRegister?

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 249 :FUNCtion:GOFT:SOURce1 (see page 750)Command Syntax

Pagina 168

What's New 1Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 25 What's New in Version 5.25New features in version 5.2

Pagina 169

250 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :FUNCtion:GOFT:SOURce2 (see page 750)Command Syntax

Pagina 170

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 251 :FUNCtion:OFFSet (see page 750)Command Syntax:FUNCt

Pagina 171 - Return Format:

252 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :FUNCtion:OPERation (see page 750)Command Syntax:FU

Pagina 172

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 253 :FUNCtion:RANGe (see page 750)Command Syntax:FUNCti

Pagina 173

254 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :FUNCtion:REFerence (see page 750)Command Syntax:FU

Pagina 174

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 255 :FUNCtion:SCALe (see page 750)Command Syntax:FUNCti

Pagina 175 - :TER (Trigger Event Register)

256 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :FUNCtion:SOURce1 (see page 750)Command Syntax:FUNC

Pagina 176

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 257 :FUNCtion:SOURce2 (see page 750)Command Syntax:FUNC

Pagina 177 - :ACQuire Commands

258 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :FUNCtion:SPAN (see page 750)Command Syntax:FUNCtio

Pagina 178

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 259 :FUNCtion:WINDow (see page 750)Command Syntax:FUNCt

Pagina 179 - :ACQuire:AALias

26 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide1 What's New ChangedCommands:TRIGger:SEQuence Commands (see page 547) C

Pagina 180 - :ACQuire:COMPlete

260 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :HARDcopy CommandsSet and query the selection of ha

Pagina 181 - :ACQuire:COUNt

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 261 Introduction to:HARDcopyCommandsThe HARDcopy subsys

Pagina 182 - :ACQuire:DAALias

262 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :HARDcopy:AREA (see page 750)Command Syntax:HARDcop

Pagina 183 - :ACQuire:MODE

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 263 :HARDcopy:APRinter (see page 750)Command Syntax:HAR

Pagina 184 - :ACQuire:POINts

264 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :HARDcopy:FACTors (see page 750)Command Syntax:HARD

Pagina 185 - :ACQuire:SEGMented:ANALyze

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 265 :HARDcopy:FFEed (see page 750)Command Syntax:HARDco

Pagina 186 - :ACQuire:SEGMented:COUNt

266 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :HARDcopy:INKSaver (see page 750)Command Syntax:HAR

Pagina 187 - :ACQuire:SEGMented:INDex

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 267 :HARDcopy:LAYout (see page 750)Command Syntax:HARDc

Pagina 188

268 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :HARDcopy:PALette (see page 750)Command Syntax:HARD

Pagina 189

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 269 :HARDcopy:PRINter:LIST (see page 750)Query Syntax:H

Pagina 190 - :ACQuire:SRATe

What's New 1Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 27 What's New in Version 5.20New features in version 5.2

Pagina 191 - :ACQuire:TYPE

270 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :HARDcopy:STARt (see page 750)Command Syntax:HARDco

Pagina 192

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 271 :LISTer CommandsIntroduction to:LISTerCommandsThe L

Pagina 193 - :CALibrate Commands

272 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :LISTer:DATA (see page 750)Query Syntax:LISTer:DATA

Pagina 194

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 273 :LISTer:DISPlay (see page 750)Command Syntax:LISTer

Pagina 195 - :CALibrate:DATE

274 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MARKer CommandsSet and query the settings of X-axi

Pagina 196 - :CALibrate:LABel

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 275 Introduction to:MARKerCommandsThe MARKer subsystem

Pagina 197 - :CALibrate:OUTPut

276 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MARKer:MODE (see page 750)Command Syntax:MARKer:MO

Pagina 198 - :CALibrate:STARt

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 277 :MARKer:X1Position (see page 750)Command Syntax:MAR

Pagina 199 - :CALibrate:STATus

278 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MARKer:X1Y1source (see page 750)Command Syntax:MAR

Pagina 200 - :CALibrate:SWITch

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 279 :MARKer:X2Position (see page 750)Command Syntax:MAR

Pagina 201 - :CALibrate:TEMPerature

28 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide1 What's New ChangedCommandsObsoleteCommandsCommand Differences:CHANnel

Pagina 202 - :CALibrate:TIME

280 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MARKer:X2Y2source (see page 750)Command Syntax:MAR

Pagina 203 - :CHANnel<n> Commands

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 281 :MARKer:XDELta (see page 750)Query Syntax:MARKer:XD

Pagina 204

282 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MARKer:Y1Position (see page 750)Command Syntax:MAR

Pagina 205

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 283 :MARKer:Y2Position (see page 750)Command Syntax:MAR

Pagina 206 - :CHANnel<n>:BWLimit

284 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MARKer:YDELta (see page 750)Query Syntax:MARKer:YD

Pagina 207 - :CHANnel<n>:COUPling

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 285 :MEASure CommandsSelect automatic measurements to b

Pagina 208 - :CHANnel<n>:DISPlay

286 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MEASure:FALLtime [<source>] (see page 300):M

Pagina 209 - :CHANnel<n>:IMPedance

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 287 :MEASure:PWIDth [<source>] (see page 308):MEA

Pagina 210 - :CHANnel<n>:INVert

288 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem n/a :MEASure:TEDGe? <slope><occurrence>

Pagina 211 - :CHANnel<n>:LABel

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 289 :MEASure:VMAX [<source>] (see page 327):MEASu

Pagina 212 - :CHANnel<n>:OFFSet

What's New 1Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 29 :MTESt:{STARt | STOP} (see page 699):RUN (see page 170) or

Pagina 213 - :CHANnel<n>:PROBe

290 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem Introduction to:MEASureCommandsThe commands in the

Pagina 214

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 291 When making measurements in the zoomed (delayed) ti

Pagina 215 - :CHANnel<n>:PROBe:ID

292 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MEASure:CLEar (see page 750)Command Syntax:MEASure

Pagina 216 - :CHANnel<n>:PROBe:SKEW

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 293 :MEASure:COUNter (see page 750)Command Syntax:MEASu

Pagina 217 - :CHANnel<n>:PROBe:STYPe

294 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MEASure:DEFine (see page 750)Command Syntax:MEASur

Pagina 218 - :CHANnel<n>:PROTection

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 295 This command defines the behavior of the :MEASure:D

Pagina 219 - :CHANnel<n>:RANGe

296 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem Return Format for <meas_spec> = DELay:{ <e

Pagina 220 - :CHANnel<n>:SCALe

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 297 :MEASure:DELay (see page 750)Command Syntax:MEASure

Pagina 221 - :CHANnel<n>:UNITs

298 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem Vtop. If you want to move the delay measurement poi

Pagina 222 - :CHANnel<n>:VERNier

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 299 :MEASure:DUTYcycle (see page 750)Command Syntax:MEA

Pagina 223 - :DISPlay Commands

Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 3In This BookThis book is your guide to programming the 5000 Series oscillosc

Pagina 224

30 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide1 What's New What's New in Version 5.15New features in version 5.1

Pagina 225 - :DISPlay:CLEar

300 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MEASure:FALLtime (see page 750)Command Syntax:MEAS

Pagina 226 - :DISPlay:DATA

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 301 :MEASure:FREQuency (see page 750)Command Syntax:MEA

Pagina 227

302 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MEASure:NWIDth (see page 750)Command Syntax:MEASur

Pagina 228 - :DISPlay:LABel

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 303 :MEASure:OVERshoot (see page 750)Command Syntax:MEA

Pagina 229 - :DISPlay:LABList

304 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem • ":MEASure:VTOP" on page 333• ":ME

Pagina 230 - :DISPlay:PERSistence

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 305 :MEASure:PERiod (see page 750)Command Syntax:MEASur

Pagina 231 - :DISPlay:SOURce

306 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MEASure:PHASe (see page 750)Command Syntax:MEASure

Pagina 232 - :DISPlay:VECTors

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 307 :MEASure:PREShoot (see page 750)Command Syntax:MEAS

Pagina 233 - :EXTernal Trigger Commands

308 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MEASure:PWIDth (see page 750)Command Syntax:MEASur

Pagina 234

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 309 :MEASure:RESults (see page 750)Query Syntax:MEASure

Pagina 235 - :EXTernal:BWLimit

What's New 1Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 31 ChangedCommandsObsoleteCommandsCommand Differences:ACQuire

Pagina 236 - :EXTernal:IMPedance

310 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem Private Declare Sub Sleep Lib "kernel32"

Pagina 237 - :EXTernal:PROBe

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 311 ValueColumnArray(5) = "Std_Dev"ValueColum

Pagina 238 - :EXTernal:PROBe:ID

312 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MEASure:RISetime (see page 750)Command Syntax:MEAS

Pagina 239

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 313 :MEASure:SDEViation (see page 750)Command Syntax:ME

Pagina 240 - :EXTernal:PROTection

314 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MEASure:SHOW (see page 750)Command Syntax:MEASure:

Pagina 241 - :EXTernal:RANGe

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 315 :MEASure:SOURce (see page 750)Command Syntax:MEASur

Pagina 242 - :EXTernal:UNITs

316 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem myScope.WriteString ":MEASURE:FREQUENCY?"

Pagina 243 - :FUNCtion Commands

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 317 :MEASure:STATistics (see page 750)Command Syntax:ME

Pagina 244

318 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MEASure:STATistics:INCRement (see page 750)Command

Pagina 245

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 319 :MEASure:STATistics:RESet (see page 750)Command Syn

Pagina 246 - :FUNCtion:CENTer

32 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide1 What's New What's New in Version 5.10New features in version 5.1

Pagina 247 - :FUNCtion:DISPlay

320 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MEASure:TEDGe (see page 750)Query Syntax:MEASure:T

Pagina 248 - :FUNCtion:GOFT:OPERation

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 321 Return Format <value><NL><value>

Pagina 249 - :FUNCtion:GOFT:SOURce1

322 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MEASure:TVALue (see page 750)Query Syntax:MEASure:

Pagina 250 - :FUNCtion:GOFT:SOURce2

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 323 <value> ::= time in seconds of the specified

Pagina 251 - :FUNCtion:OFFSet

324 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MEASure:VAMPlitude (see page 750)Command Syntax:ME

Pagina 252 - :FUNCtion:OPERation

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 325 :MEASure:VAVerage (see page 750)Command Syntax:MEAS

Pagina 253 - :FUNCtion:RANGe

326 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MEASure:VBASe (see page 750)Command Syntax:MEASure

Pagina 254 - :FUNCtion:REFerence

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 327 :MEASure:VMAX (see page 750)Command Syntax:MEASure:

Pagina 255 - :FUNCtion:SCALe

328 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MEASure:VMIN (see page 750)Command Syntax:MEASure:

Pagina 256 - :FUNCtion:SOURce1

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 329 :MEASure:VPP (see page 750)Command Syntax:MEASure:V

Pagina 257 - :FUNCtion:SOURce2

What's New 1Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 33 What's New in Version 5.00New features in version 5.0

Pagina 258 - :FUNCtion:SPAN

330 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MEASure:VRATio (see page 750)Command Syntax:MEASur

Pagina 259 - :FUNCtion:WINDow

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 331 :MEASure:VRMS (see page 750)Command Syntax:MEASure:

Pagina 260 - :HARDcopy Commands

332 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MEASure:VTIMe (see page 750)Query Syntax:MEASure:V

Pagina 261

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 333 :MEASure:VTOP (see page 750)Command Syntax:MEASure:

Pagina 262 - :HARDcopy:AREA

334 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MEASure:WINDow (see page 750)Command Syntax:MEASur

Pagina 263 - :HARDcopy:APRinter

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 335 :MEASure:XMAX (see page 750)Command Syntax:MEASure:

Pagina 264 - :HARDcopy:FACTors

336 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MEASure:XMIN (see page 750)Command Syntax:MEASure:

Pagina 265 - :HARDcopy:FFEed

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 337 :MTESt CommandsThe MTESt subsystem commands and que

Pagina 266 - :HARDcopy:INKSaver

338 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MTESt:OUTPut <signal> (see page 355):MTESt:O

Pagina 267 - :HARDcopy:LAYout

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 339 Introduction to:MTEStCommandsMask testing automatic

Pagina 268 - :HARDcopy:PALette

34 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide1 What's New ChangedCommandsObsoleteCommandsCommand Differences:BLANk (

Pagina 269 - :HARDcopy:PRINter:LIST

340 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem Set myMgr = New VisaComLib.ResourceManagerSet mySco

Pagina 270 - :HARDcopy:STARt

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 341 lngElapsed = 0Do While lngElapsed <= lngTimeoutm

Pagina 271 - :LISTer Commands

342 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MTESt:AMASk:CREate (see page 750)Command Syntax:MT

Pagina 272 - :LISTer:DATA

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 343 :MTESt:AMASk:SOURce (see page 750)Command Syntax:MT

Pagina 273 - :LISTer:DISPlay

344 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MTESt:AMASk:UNITs (see page 750)Command Syntax:MTE

Pagina 274 - :MARKer Commands

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 345 :MTESt:AMASk:XDELta (see page 750)Command Syntax:MT

Pagina 275

346 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MTESt:AMASk:YDELta (see page 750)Command Syntax:MT

Pagina 276 - :MARKer:MODE

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 347 :MTESt:COUNt:FWAVeforms (see page 750)Query Syntax:

Pagina 277 - :MARKer:X1Position

348 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MTESt:COUNt:RESet (see page 750)Command Syntax:MTE

Pagina 278 - :MARKer:X1Y1source

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 349 :MTESt:COUNt:TIME (see page 750)Query Syntax:MTESt:

Pagina 279 - :MARKer:X2Position

What's New 1Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 35 What's New in Version 4.10New features in version 4.1

Pagina 280 - :MARKer:X2Y2source

350 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MTESt:COUNt:WAVeforms (see page 750)Query Syntax:M

Pagina 281 - :MARKer:XDELta

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 351 :MTESt:DATA (see page 750)Command Syntax:MTESt:DATA

Pagina 282 - :MARKer:Y1Position

352 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MTESt:DELete (see page 750)Command Syntax:MTESt:DE

Pagina 283 - :MARKer:Y2Position

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 353 :MTESt:ENABle (see page 750)Command Syntax:MTESt:EN

Pagina 284 - :MARKer:YDELta

354 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MTESt:LOCK (see page 750)Command Syntax:MTESt:LOCK

Pagina 285 - :MEASure Commands

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 355 :MTESt:OUTPut (see page 750)Command Syntax:MTESt:OU

Pagina 286

356 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MTESt:RMODe (see page 750)Command Syntax:MTESt:RMO

Pagina 287

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 357 :MTESt:RMODe:FACTion:MEASure (see page 750)Command

Pagina 288

358 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MTESt:RMODe:FACTion:PRINt (see page 750)Command Sy

Pagina 289

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 359 :MTESt:RMODe:FACTion:SAVE (see page 750)Command Syn

Pagina 290

36 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide1 What's New Version 4.00 at IntroductionThe Agilent InfiniiVision 5000

Pagina 291

360 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MTESt:RMODe:FACTion:STOP (see page 750)Command Syn

Pagina 292 - :MEASure:CLEar

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 361 :MTESt:RMODe:SIGMa (see page 750)Command Syntax:MTE

Pagina 293 - :MEASure:COUNter

362 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MTESt:RMODe:TIME (see page 750)Command Syntax:MTES

Pagina 294 - :MEASure:DEFine

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 363 :MTESt:RMODe:WAVeforms (see page 750)Command Syntax

Pagina 295

364 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MTESt:SCALe:BIND (see page 750)Command Syntax:MTES

Pagina 296

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 365 :MTESt:SCALe:X1 (see page 750)Command Syntax:MTESt:

Pagina 297 - :MEASure:DELay

366 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MTESt:SCALe:XDELta (see page 750)Command Syntax:MT

Pagina 298

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 367 :MTESt:SCALe:Y1 (see page 750)Command Syntax:MTESt:

Pagina 299 - :MEASure:DUTYcycle

368 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MTESt:SCALe:Y2 (see page 750)Command Syntax:MTESt:

Pagina 300 - :MEASure:FALLtime

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 369 :MTESt:SOURce (see page 750)Command Syntax:MTESt:SO

Pagina 301 - :MEASure:FREQuency

37 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide2Setting UpStep 1. Install Agilent IO Libraries Suite software 38Step 2. C

Pagina 302 - :MEASure:NWIDth

370 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :MTESt:TITLe (see page 750)Query Syntax:MTESt:TITLe

Pagina 303 - :MEASure:OVERshoot

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 371 :RECall CommandsRecall previously saved oscilloscop

Pagina 304

372 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :RECall:FILename (see page 750)Command Syntax:RECal

Pagina 305 - :MEASure:PERiod

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 373 :RECall:IMAGe[:STARt] (see page 750)Command Syntax:

Pagina 306 - :MEASure:PHASe

374 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :RECall:MASK[:STARt] (see page 750)Command Syntax:R

Pagina 307 - :MEASure:PREShoot

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 375 :RECall:PWD (see page 750)Command Syntax:RECall:PWD

Pagina 308 - :MEASure:PWIDth

376 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :RECall:SETup[:STARt] (see page 750)Command Syntax:

Pagina 309 - :MEASure:RESults

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 377 :SAVE CommandsSave oscilloscope setups and traces,

Pagina 310

378 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem Introduction to:SAVE CommandsThe :SAVE subsystem pr

Pagina 311

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 379 :SAVE:FILename (see page 750)Command Syntax:SAVE:FI

Pagina 312 - :MEASure:RISetime

38 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide2 Setting Up Step 1. Install Agilent IO Libraries Suite softwareInsert the A

Pagina 313 - :MEASure:SDEViation

380 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :SAVE:IMAGe[:STARt] (see page 750)Command Syntax:SA

Pagina 314 - :MEASure:SHOW

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 381 :SAVE:IMAGe:AREA (see page 750)Query Syntax:SAVE:IM

Pagina 315 - :MEASure:SOURce

382 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :SAVE:IMAGe:FACTors (see page 750)Command Syntax:SA

Pagina 316

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 383 :SAVE:IMAGe:FORMat (see page 750)Command Syntax:SAV

Pagina 317 - :MEASure:STATistics

384 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :SAVE:IMAGe:INKSaver (see page 750)Command Syntax:S

Pagina 318 - :MEASure:STATistics:INCRement

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 385 :SAVE:IMAGe:PALette (see page 750)Command Syntax:SA

Pagina 319 - :MEASure:STATistics:RESet

386 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :SAVE:LISTer[:STARt] (see page 750)Command Syntax:S

Pagina 320 - :MEASure:TEDGe

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 387 :SAVE:MASK[:STARt] (see page 750)Command Syntax:SAV

Pagina 321

388 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :SAVE:PWD (see page 750)Command Syntax:SAVE:PWD <

Pagina 322 - :MEASure:TVALue

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 389 :SAVE:SETup[:STARt] (see page 750)Command Syntax:SA

Pagina 323

Setting Up 2Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 39 Step 2. Connect and set up the oscilloscopeThe 5000 Series osci

Pagina 324 - :MEASure:VAMPlitude

390 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :SAVE:WAVeform[:STARt] (see page 750)Command Syntax

Pagina 325 - :MEASure:VAVerage

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 391 :SAVE:WAVeform:FORMat (see page 750)Command Syntax:

Pagina 326 - :MEASure:VBASe

392 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :SAVE:WAVeform:LENGth (see page 750)Command Syntax:

Pagina 327 - :MEASure:VMAX

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 393 :SAVE:WAVeform:SEGMented (see page 750)Command Synt

Pagina 328 - :MEASure:VMIN

394 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :SBUS CommandsControl oscilloscope functions associ

Pagina 329 - :MEASure:VPP

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 395 Introduction to:SBUSCommandsThe :SBUS subsystem com

Pagina 330 - :MEASure:VRATio

396 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :SBUS:CAN:COUNt:ERRor (see page 750)Query Syntax:SB

Pagina 331 - :MEASure:VRMS

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 397 :SBUS:CAN:COUNt:OVERload (see page 750)Query Syntax

Pagina 332 - :MEASure:VTIMe

398 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :SBUS:CAN:COUNt:RESet (see page 750)Command Syntax:

Pagina 333 - :MEASure:VTOP

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 399 :SBUS:CAN:COUNt:TOTal (see page 750)Query Syntax:SB

Pagina 334 - :MEASure:WINDow

4 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's GuideThen, there are chapters that describe programming topics and conceptual inf

Pagina 335 - :MEASure:XMAX

40 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide2 Setting Up 4 On the oscilloscope, verify that the controller interface is

Pagina 336 - :MEASure:XMIN

400 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :SBUS:CAN:COUNt:UTILization (see page 750)Query Syn

Pagina 337 - :MTESt Commands

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 401 :SBUS:DISPlay (see page 750)Command Syntax:SBUS:DIS

Pagina 338

402 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :SBUS:FLEXray:COUNt:NULL (see page 750)Query Syntax

Pagina 339

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 403 :SBUS:FLEXray:COUNt:RESet (see page 750)Command Syn

Pagina 340

404 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :SBUS:FLEXray:COUNt:SYNC (see page 750)Query Syntax

Pagina 341

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 405 :SBUS:FLEXray:COUNt:TOTal (see page 750)Query Synta

Pagina 342 - :MTESt:AMASk:CREate

406 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :SBUS:I2S:BASE (see page 750)Command Syntax:SBUS:I2

Pagina 343 - :MTESt:AMASk:SOURce

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 407 :SBUS:IIC:ASIZe (see page 750)Command Syntax:SBUS:I

Pagina 344 - :MTESt:AMASk:UNITs

408 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :SBUS:LIN:PARity (see page 750)Command Syntax:SBUS:

Pagina 345 - :MTESt:AMASk:XDELta

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 409 :SBUS:M1553:BASE (see page 750)Command Syntax:SBUS:

Pagina 346 - :MTESt:AMASk:YDELta

Setting Up 2Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 41 Step 3. Verify the oscilloscope connection1 On the controller P

Pagina 347 - :MTESt:COUNt:FWAVeforms

410 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :SBUS:MODE (see page 750)Command Syntax:SBUS:MODE &

Pagina 348 - :MTESt:COUNt:RESet

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 411 :SBUS:SPI:BITorder (see page 750)Command Syntax:SBU

Pagina 349 - :MTESt:COUNt:TIME

412 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :SBUS:SPI:WIDTh (see page 750)Command Syntax:SBUS:S

Pagina 350 - :MTESt:COUNt:WAVeforms

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 413 :SBUS:UART:BASE (see page 750)Command Syntax:SBUS:U

Pagina 351 - :MTESt:DATA

414 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :SBUS:UART:COUNt:ERRor (see page 750)Query Syntax:S

Pagina 352 - :MTESt:DELete

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 415 :SBUS:UART:COUNt:RESet (see page 750)Command Syntax

Pagina 353 - :MTESt:ENABle

416 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :SBUS:UART:COUNt:RXFRames (see page 750)Query Synta

Pagina 354 - :MTESt:LOCK

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 417 :SBUS:UART:COUNt:TXFRames (see page 750)Query Synta

Pagina 355 - :MTESt:OUTPut

418 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :SBUS:UART:FRAMing (see page 750)Command Syntax:SBU

Pagina 356 - :MTESt:RMODe

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 419 :SYSTem CommandsControl basic system functions of t

Pagina 357 - :MTESt:RMODe:FACTion:MEASure

42 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide2 Setting Up You must manually add instruments on LAN interfaces:a Right-cli

Pagina 358 - :MTESt:RMODe:FACTion:PRINt

420 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :SYSTem:DATE (see page 750)Command Syntax:SYSTem:DA

Pagina 359 - :MTESt:RMODe:FACTion:SAVE

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 421 :SYSTem:DSP (see page 750)Command Syntax:SYSTem:DSP

Pagina 360 - :MTESt:RMODe:FACTion:STOP

422 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :SYSTem:ERRor (see page 750)Query Syntax:SYSTem:ERR

Pagina 361 - :MTESt:RMODe:SIGMa

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 423 :SYSTem:LOCK (see page 750)Command Syntax:SYSTem:LO

Pagina 362 - :MTESt:RMODe:TIME

424 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :SYSTem:PRECision (see page 750)Command Syntax:SYST

Pagina 363 - :MTESt:RMODe:WAVeforms

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 425 :SYSTem:PROTection:LOCK (see page 750)Command Synta

Pagina 364 - :MTESt:SCALe:BIND

426 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :SYSTem:SETup (see page 750)Command Syntax:SYSTem:S

Pagina 365 - :MTESt:SCALe:X1

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 427 ' Write setup string back to oscilloscope usin

Pagina 366 - :MTESt:SCALe:XDELta

428 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :SYSTem:TIME (see page 750)Command Syntax:SYSTem:TI

Pagina 367 - :MTESt:SCALe:Y1

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 429 :TIMebase CommandsControl all horizontal sweep func

Pagina 368 - :MTESt:SCALe:Y2

Setting Up 2Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 43 Otherwise, if the instrument is not on the same subnet, click A

Pagina 369 - :MTESt:SOURce

430 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem Use :TIMebase? to query setup information for the T

Pagina 370 - :MTESt:TITLe

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 431 :TIMebase:MODE (see page 750)Command Syntax:TIMebas

Pagina 371 - :RECall Commands

432 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TIMebase:POSition (see page 750)Command Syntax:TIM

Pagina 372 - :RECall:FILename

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 433 :TIMebase:RANGe (see page 750)Command Syntax:TIMeba

Pagina 373 - :RECall:IMAGe[:STARt]

434 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TIMebase:REFerence (see page 750)Command Syntax:TI

Pagina 374 - :RECall:MASK[:STARt]

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 435 :TIMebase:SCALe (see page 750)Command Syntax:TIMeba

Pagina 375 - :RECall:PWD

436 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TIMebase:VERNier (see page 750)Command Syntax:TIMe

Pagina 376 - :RECall:SETup[:STARt]

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 437 :TIMebase:WINDow:POSition (see page 750)Command Syn

Pagina 377 - :SAVE Commands

438 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TIMebase:WINDow:RANGe (see page 750)Command Syntax

Pagina 378

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 439 :TIMebase:WINDow:SCALe (see page 750)Command Syntax

Pagina 379 - :SAVE:FILename

44 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide2 Setting Up iii If the instrument is successfully opened, click OK to close

Pagina 380 - :SAVE:IMAGe[:STARt]

440 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger CommandsControl the trigger modes and para

Pagina 381 - :SAVE:IMAGe:AREA

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 441 The following trigger types are available (see &quo

Pagina 382 - :SAVE:IMAGe:FACTors

442 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem • Sequence triggering— allows you to trigger the os

Pagina 383 - :SAVE:IMAGe:FORMat

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 443 General :TRIGger CommandsTable 69 General :TRIGger

Pagina 384 - :SAVE:IMAGe:INKSaver

444 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:HFReject (see page 750)Command Syntax:TRIG

Pagina 385 - :SAVE:IMAGe:PALette

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 445 :TRIGger:HOLDoff (see page 750)Command Syntax:TRIGg

Pagina 386 - :SAVE:LISTer[:STARt]

446 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:LFIFty (see page 750)Command Syntax:TRIGge

Pagina 387 - :SAVE:MASK[:STARt]

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 447 :TRIGger:MODE (see page 750)Command Syntax:TRIGger:

Pagina 388 - :SAVE:PWD

448 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:NREJect (see page 750)Command Syntax:TRIGg

Pagina 389 - :SAVE:SETup[:STARt]

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 449 :TRIGger:PATTern (see page 750)Command Syntax:TRIGg

Pagina 390 - :SAVE:WAVeform[:STARt]

Setting Up 2Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 45 3 Test some commands on the instrument:a Right- click on the in

Pagina 391 - :SAVE:WAVeform:FORMat

450 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem • ":TRIGger:MODE" on page 447

Pagina 392 - :SAVE:WAVeform:LENGth

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 451 :TRIGger:SWEep (see page 750)Command Syntax:TRIGger

Pagina 393 - :SAVE:WAVeform:SEGMented

452 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:CAN CommandsTable 70 :TRIGger:CAN Commands

Pagina 394 - :SBUS Commands

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 453 :TRIGger:CAN:SIGNal:DEFinition <value> (see p

Pagina 395 - :SBUS:DISP 0;MODE IIC

454 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:CAN:PATTern:DATA (see page 750)Command Syn

Pagina 396 - :SBUS:CAN:COUNt:ERRor

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 455 :TRIGger:CAN:PATTern:DATA:LENGth (see page 750)Comm

Pagina 397 - :SBUS:CAN:COUNt:OVERload

456 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:CAN:PATTern:ID (see page 750)Command Synta

Pagina 398 - :SBUS:CAN:COUNt:RESet

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 457 :TRIGger:CAN:PATTern:ID:MODE (see page 750)Command

Pagina 399 - :SBUS:CAN:COUNt:TOTal

458 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:CAN:SAMPlepoint (see page 750)Command Synt

Pagina 400 - :SBUS:CAN:COUNt:UTILization

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 459 :TRIGger:CAN:SIGNal:BAUDrate (see page 750)Command

Pagina 401 - :SBUS:DISPlay

46 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide2 Setting Up

Pagina 402 - :SBUS:FLEXray:COUNt:NULL

460 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:CAN:SIGNal:DEFinition (see page 750)Comman

Pagina 403 - :SBUS:FLEXray:COUNt:RESet

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 461 :TRIGger:CAN:SOURce (see page 750)Command Syntax:TR

Pagina 404 - :SBUS:FLEXray:COUNt:SYNC

462 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:CAN:TRIGger (see page 750)Command Syntax:T

Pagina 405 - :SBUS:FLEXray:COUNt:TOTal

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 463 CAN Id specification is set by the :TRIGger:CAN:PAT

Pagina 406 - :SBUS:I2S:BASE

464 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:DURation CommandsTable 71 :TRIGger:DURatio

Pagina 407 - :SBUS:IIC:ASIZe

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 465 :TRIGger:DURation:GREaterthan (see page 750)Command

Pagina 408 - :SBUS:LIN:PARity

466 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:DURation:LESSthan (see page 750)Command Sy

Pagina 409 - :SBUS:M1553:BASE

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 467 :TRIGger:DURation:PATTern (see page 750)Command Syn

Pagina 410 - :SBUS:MODE

468 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:DURation:QUALifier (see page 750)Command S

Pagina 411 - :SBUS:SPI:BITorder

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 469 :TRIGger:DURation:RANGe (see page 750)Command Synta

Pagina 412 - :SBUS:SPI:WIDTh

47 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide3Getting StartedBasic Oscilloscope Program Structure 48Programming the Osc

Pagina 413 - :SBUS:UART:BASE

470 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:EBURst CommandsThe :TRIGger:EDGE:SOURce co

Pagina 414 - :SBUS:UART:COUNt:ERRor

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 471 :TRIGger:EBURst:COUNt (see page 750)Command Syntax:

Pagina 415 - :SBUS:UART:COUNt:RESet

472 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:EBURst:IDLE (see page 750)Command Syntax:T

Pagina 416 - :SBUS:UART:COUNt:RXFRames

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 473 :TRIGger:EBURst:SLOPe (see page 750)Command Syntax:

Pagina 417 - :SBUS:UART:COUNt:TXFRames

474 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger[:EDGE] CommandsTable 73 :TRIGger[:EDGE] Co

Pagina 418 - :SBUS:UART:FRAMing

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 475 :TRIGger[:EDGE]:COUPling (see page 750)Command Synt

Pagina 419 - :SYSTem Commands

476 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger[:EDGE]:LEVel (see page 750)Command Syntax:

Pagina 420 - :SYSTem:DATE

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 477 :TRIGger[:EDGE]:REJect (see page 750)Command Syntax

Pagina 421 - :SYSTem:DSP

478 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger[:EDGE]:SLOPe (see page 750)Command Syntax:

Pagina 422 - :SYSTem:ERRor

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 479 :TRIGger[:EDGE]:SOURce (see page 750)Command Syntax

Pagina 423 - :SYSTem:LOCK

48 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide3 Getting Started Basic Oscilloscope Program StructureThe following figure s

Pagina 424 - :SYSTem:PRECision

480 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:FLEXray CommandsTable 74 :TRIGger:FLEXray

Pagina 425 - :SYSTem:PROTection:LOCK

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 481 :TRIGger:FLEXray:AUTosetup (see page 750)Command Sy

Pagina 426 - :SYSTem:SETup

482 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:FLEXray:BAUDrate (see page 750)Command Syn

Pagina 427

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 483 :TRIGger:FLEXray:CHANnel (see page 750)Command Synt

Pagina 428 - :SYSTem:TIME

484 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:FLEXray:ERRor:TYPE (see page 750)Command S

Pagina 429 - :TIMebase Commands

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 485 :TRIGger:FLEXray:EVENt:TYPE (see page 750)Command S

Pagina 430

486 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:FLEXray:FRAMe:CCBase (see page 750)Command

Pagina 431 - :TIMebase:MODE

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 487 :TRIGger:FLEXray:FRAMe:CCRepetition (see page 750)C

Pagina 432 - :TIMebase:POSition

488 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:FLEXray:FRAMe:ID (see page 750)Command Syn

Pagina 433 - :TIMebase:RANGe

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 489 :TRIGger:FLEXray:FRAMe:TYPE (see page 750)Command S

Pagina 434 - :TIMebase:REFerence

Getting Started 3Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 49 To collect data, you use the :DIGitize command. This comma

Pagina 435 - :TIMebase:SCALe

490 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:FLEXray:SOURce (see page 750)Command Synta

Pagina 436 - :TIMebase:VERNier

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 491 :TRIGger:FLEXray:TRIGger (see page 750)Command Synt

Pagina 437 - :TIMebase:WINDow:POSition

492 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:GLITch CommandsTable 75 :TRIGger:GLITch Co

Pagina 438 - :TIMebase:WINDow:RANGe

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 493 :TRIGger:GLITch:GREaterthan (see page 750)Command S

Pagina 439 - :TIMebase:WINDow:SCALe

494 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:GLITch:LESSthan (see page 750)Command Synt

Pagina 440 - :TRIGger Commands

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 495 :TRIGger:GLITch:LEVel (see page 750)Command Syntax:

Pagina 441

496 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:GLITch:POLarity (see page 750)Command Synt

Pagina 442

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 497 :TRIGger:GLITch:QUALifier (see page 750)Command Syn

Pagina 443 - General :TRIGger Commands

498 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:GLITch:RANGe (see page 750)Command Syntax:

Pagina 444 - :TRIGger:HFReject

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 499 :TRIGger:GLITch:SOURce (see page 750)Command Syntax

Pagina 445 - :TRIGger:HOLDoff

Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 5 ContentsIn This Book 31 What's NewWhat's New in Version 6.10 22Wha

Pagina 446 - :TRIGger:LFIFty

50 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide3 Getting Started Programming the Oscilloscope• "Referencing the IO Lib

Pagina 447 - :TRIGger:MODE

500 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:I2S CommandsTable 76 :TRIGger:I2S Commands

Pagina 448 - :TRIGger:NREJect

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 501 :TRIGger:I2S:SOURce:DATA <source> (see page 5

Pagina 449 - :TRIGger:PATTern

502 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:I2S:ALIGnment (see page 750)Command Syntax

Pagina 450

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 503 :TRIGger:I2S:AUDio (see page 750)Command Syntax:TRI

Pagina 451 - :TRIGger:SWEep

504 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:I2S:CLOCk:SLOPe (see page 750)Command Synt

Pagina 452 - :TRIGger:CAN Commands

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 505 :TRIGger:I2S:PATTern:DATA (see page 750)Command Syn

Pagina 453

506 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem Query Syntax :TRIGger:I2S:PATTern:DATA?The :TRIGger

Pagina 454 - :TRIGger:CAN:PATTern:DATA

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 507 :TRIGger:I2S:PATTern:FORMat (see page 750)Command S

Pagina 455

508 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:I2S:RANGe (see page 750)Command Syntax:TRI

Pagina 456 - :TRIGger:CAN:PATTern:ID

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 509 • ":TRIGger:I2S:TRIGger" on page 514• &q

Pagina 457 - :TRIGger:CAN:PATTern:ID:MODE

Getting Started 3Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 51 3 Click OK.To reference the Agilent VISA COM library in M

Pagina 458 - :TRIGger:CAN:SAMPlepoint

510 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:I2S:RWIDth (see page 750)Command Syntax:TR

Pagina 459 - :TRIGger:CAN:SIGNal:BAUDrate

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 511 :TRIGger:I2S:SOURce:CLOCk (see page 750)Command Syn

Pagina 460

512 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:I2S:SOURce:DATA (see page 750)Command Synt

Pagina 461 - :TRIGger:CAN:SOURce

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 513 :TRIGger:I2S:SOURce:WSELect (see page 750)Command S

Pagina 462 - :TRIGger:CAN:TRIGger

514 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:I2S:TRIGger (see page 750)Command Syntax:T

Pagina 463

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 515 The :TRIGger:I2S:TRIGger? query returns the current

Pagina 464 - :TRIGger:DURation Commands

516 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:I2S:TWIDth (see page 750)Command Syntax:TR

Pagina 465 - :TRIGger:DURation:GREaterthan

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 517 :TRIGger:I2S:WSLow (see page 750)Command Syntax:TRI

Pagina 466 - :TRIGger:DURation:LESSthan

518 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:IIC CommandsTable 77 :TRIGger:IIC Commands

Pagina 467 - :TRIGger:DURation:PATTern

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 519 :TRIGger:IIC:PATTern:ADDRess (see page 750)Command

Pagina 468 - :TRIGger:DURation:QUALifier

52 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide3 Getting Started Dim myMgr As VisaComLib.ResourceManagerDim myScope As Visa

Pagina 469 - :TRIGger:DURation:RANGe

520 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:IIC:PATTern:DATA (see page 750)Command Syn

Pagina 470 - :TRIGger:EBURst Commands

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 521 :TRIGger:IIC:PATTern:DATa2 (see page 750)Command Sy

Pagina 471 - :TRIGger:EBURst:COUNt

522 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:IIC[:SOURce]:CLOCk (see page 750)Command S

Pagina 472 - :TRIGger:EBURst:IDLE

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 523 :TRIGger:IIC[:SOURce]:DATA (see page 750)Command Sy

Pagina 473 - :TRIGger:EBURst:SLOPe

524 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:IIC:TRIGger:QUALifier (see page 750)Comman

Pagina 474 - :TRIGger[:EDGE] Commands

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 525 :TRIGger:IIC:TRIGger[:TYPE] (see page 750)Command S

Pagina 475 - :TRIGger[:EDGE]:COUPling

526 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem • ":TRIGger:IIC:PATTern:ADDRess" on page

Pagina 476 - :TRIGger[:EDGE]:LEVel

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 527 :TRIGger:LIN CommandsTable 78 :TRIGger:LIN Commands

Pagina 477 - :TRIGger[:EDGE]:REJect

528 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:LIN:SYNCbreak <value> (see page 538)

Pagina 478 - :TRIGger[:EDGE]:SLOPe

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 529 :TRIGger:LIN:ID (see page 750)Command Syntax:TRIGge

Pagina 479 - :TRIGger[:EDGE]:SOURce

Getting Started 3Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 53 Vertical is set to 16 V full- scale (2 V/div) with center

Pagina 480 - :TRIGger:FLEXray Commands

530 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:LIN:PATTern:DATA (see page 750)Command Syn

Pagina 481 - :TRIGger:FLEXray:AUTosetup

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 531 Query Syntax :TRIGger:LIN:PATTern:DATA?The :TRIGger

Pagina 482 - :TRIGger:FLEXray:BAUDrate

532 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:LIN:PATTern:DATA:LENGth (see page 750)Comm

Pagina 483 - :TRIGger:FLEXray:CHANnel

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 533 :TRIGger:LIN:PATTern:FORMat (see page 750)Command S

Pagina 484 - :TRIGger:FLEXray:ERRor:TYPE

534 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:LIN:SAMPlepoint (see page 750)Command Synt

Pagina 485 - :TRIGger:FLEXray:EVENt:TYPE

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 535 :TRIGger:LIN:SIGNal:BAUDrate (see page 750)Command

Pagina 486 - :TRIGger:FLEXray:FRAMe:CCBase

536 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:LIN:SOURce (see page 750)Command Syntax:TR

Pagina 487

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 537 :TRIGger:LIN:STANdard (see page 750)Command Syntax:

Pagina 488 - :TRIGger:FLEXray:FRAMe:ID

538 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:LIN:SYNCbreak (see page 750)Command Syntax

Pagina 489 - :TRIGger:FLEXray:FRAMe:TYPE

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 539 :TRIGger:LIN:TRIGger (see page 750)Command Syntax:T

Pagina 490 - :TRIGger:FLEXray:SOURce

54 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide3 Getting Started When you send the :DIGitize command to the oscilloscope, t

Pagina 491 - :TRIGger:FLEXray:TRIGger

540 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:M1553 CommandsTable 79 :TRIGger:M1553 Comm

Pagina 492 - :TRIGger:GLITch Commands

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 541 :TRIGger:M1553:AUTosetup (see page 750)Command Synt

Pagina 493 - :TRIGger:GLITch:GREaterthan

542 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:M1553:PATTern:DATA (see page 750)Command S

Pagina 494 - :TRIGger:GLITch:LESSthan

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 543 :TRIGger:M1553:RTA (see page 750)Command Syntax:TRI

Pagina 495 - :TRIGger:GLITch:LEVel

544 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:M1553:SOURce:LOWer (see page 750)Command S

Pagina 496 - :TRIGger:GLITch:POLarity

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 545 :TRIGger:M1553:SOURce:UPPer (see page 750)Command S

Pagina 497 - :TRIGger:GLITch:QUALifier

546 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:M1553:TYPE (see page 750)Command Syntax:TR

Pagina 498 - :TRIGger:GLITch:RANGe

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 547 :TRIGger:SEQuence CommandsTable 80 :TRIGger:SEQuenc

Pagina 499 - :TRIGger:GLITch:SOURce

548 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:SEQuence:COUNt (see page 750)Command Synta

Pagina 500 - :TRIGger:I2S Commands

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 549 :TRIGger:SEQuence:EDGE (see page 750)Command Syntax

Pagina 501

Getting Started 3Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 55 The easiest method of transferring a digitized waveform de

Pagina 502 - :TRIGger:I2S:ALIGnment

550 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:SEQuence:FIND (see page 750)Command Syntax

Pagina 503 - :TRIGger:I2S:AUDio

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 551 :TRIGger:SEQuence:PATTern (see page 750)Command Syn

Pagina 504 - :TRIGger:I2S:CLOCk:SLOPe

552 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:SEQuence:RESet (see page 750)Command Synta

Pagina 505 - :TRIGger:I2S:PATTern:DATA

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 553 :TRIGger:SEQuence:TIMer (see page 750)Command Synta

Pagina 506

554 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:SEQuence:TRIGger (see page 750)Command Syn

Pagina 507 - :TRIGger:I2S:PATTern:FORMat

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 555 :TRIGger:SPI CommandsTable 81 :TRIGger:SPI Commands

Pagina 508 - :TRIGger:I2S:RANGe

556 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:SPI:CLOCk:SLOPe (see page 750)Command Synt

Pagina 509

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 557 :TRIGger:SPI:CLOCk:TIMeout (see page 750)Command Sy

Pagina 510 - :TRIGger:I2S:RWIDth

558 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:SPI:FRAMing (see page 750)Command Syntax:T

Pagina 511 - :TRIGger:I2S:SOURce:CLOCk

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 559 :TRIGger:SPI:PATTern:DATA (see page 750)Command Syn

Pagina 512 - :TRIGger:I2S:SOURce:DATA

56 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide3 Getting Started Reading Query Results into String VariablesThe output of t

Pagina 513 - :TRIGger:I2S:SOURce:WSELect

560 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:SPI:PATTern:WIDTh (see page 750)Command Sy

Pagina 514 - :TRIGger:I2S:TRIGger

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 561 :TRIGger:SPI:SOURce:CLOCk (see page 750)Command Syn

Pagina 515

562 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:SPI:SOURce:DATA (see page 750)Command Synt

Pagina 516 - :TRIGger:I2S:TWIDth

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 563 :TRIGger:SPI:SOURce:FRAMe (see page 750)Command Syn

Pagina 517 - :TRIGger:I2S:WSLow

564 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:TV CommandsTable 82 :TRIGger:TV Commands S

Pagina 518 - :TRIGger:IIC Commands

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 565 :TRIGger:TV:LINE (see page 750)Command Syntax:TRIGg

Pagina 519 - :TRIGger:IIC:PATTern:ADDRess

566 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:TV:MODE (see page 750)Command Syntax:TRIGg

Pagina 520 - :TRIGger:IIC:PATTern:DATA

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 567 :TRIGger:TV:POLarity (see page 750)Command Syntax:T

Pagina 521 - :TRIGger:IIC:PATTern:DATa2

568 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:TV:SOURce (see page 750)Command Syntax:TRI

Pagina 522 - :TRIGger:IIC[:SOURce]:CLOCk

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 569 :TRIGger:TV:STANdard (see page 750)Command Syntax:T

Pagina 523 - :TRIGger:IIC[:SOURce]:DATA

Getting Started 3Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 57 The "8" states the number of digits that follow,

Pagina 524

570 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:UART CommandsTable 84 :TRIGger:UART Comman

Pagina 525 - :TRIGger:IIC:TRIGger[:TYPE]

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 571 :TRIGger:UART:SOURce:TX <source> (see page 58

Pagina 526

572 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:UART:BASE (see page 750)Command Syntax:TRI

Pagina 527 - :TRIGger:LIN Commands

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 573 :TRIGger:UART:BAUDrate (see page 750)Command Syntax

Pagina 528

574 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:UART:BITorder (see page 750)Command Syntax

Pagina 529 - :TRIGger:LIN:ID

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 575 :TRIGger:UART:BURSt (see page 750)Command Syntax:TR

Pagina 530 - :TRIGger:LIN:PATTern:DATA

576 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:UART:DATA (see page 750)Command Syntax:TRI

Pagina 531

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 577 :TRIGger:UART:IDLE (see page 750)Command Syntax:TRI

Pagina 532

578 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:UART:PARity (see page 750)Command Syntax:T

Pagina 533 - :TRIGger:LIN:PATTern:FORMat

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 579 :TRIGger:UART:POLarity (see page 750)Command Syntax

Pagina 534 - :TRIGger:LIN:SAMPlepoint

58 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide3 Getting Started strResults() = myScope.ReadList(ASCIIType_BSTR)MsgBox &quo

Pagina 535 - :TRIGger:LIN:SIGNal:BAUDrate

580 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:UART:QUALifier (see page 750)Command Synta

Pagina 536 - :TRIGger:LIN:SOURce

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 581 :TRIGger:UART:SOURce:RX (see page 750)Command Synta

Pagina 537 - :TRIGger:LIN:STANdard

582 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:UART:SOURce:TX (see page 750)Command Synta

Pagina 538 - :TRIGger:LIN:SYNCbreak

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 583 :TRIGger:UART:TYPE (see page 750)Command Syntax:TRI

Pagina 539 - :TRIGger:LIN:TRIGger

584 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:UART:WIDTh (see page 750)Command Syntax:TR

Pagina 540 - :TRIGger:M1553 Commands

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 585 :TRIGger:USB CommandsTable 85 :TRIGger:USB Commands

Pagina 541 - :TRIGger:M1553:AUTosetup

586 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:USB:SOURce:DMINus (see page 750)Command Sy

Pagina 542 - :TRIGger:M1553:PATTern:DATA

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 587 :TRIGger:USB:SOURce:DPLus (see page 750)Command Syn

Pagina 543 - :TRIGger:M1553:RTA

588 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :TRIGger:USB:SPEed (see page 750)Command Syntax:TRI

Pagina 544 - :TRIGger:M1553:SOURce:LOWer

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 589 :TRIGger:USB:TRIGger (see page 750)Command Syntax:T

Pagina 545 - :TRIGger:M1553:SOURce:UPPer

Getting Started 3Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 59 Other Ways of Sending CommandsStandard Commands for Progra

Pagina 546 - :TRIGger:M1553:TYPE

590 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :WAVeform CommandsProvide access to waveform data.

Pagina 547 - :TRIGger:SEQuence Commands

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 591 n/a :WAVeform:PREamble? (see page 606)<preamble_

Pagina 548 - :TRIGger:SEQuence:COUNt

592 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem Introduction to:WAVeformCommandsThe WAVeform subsys

Pagina 549 - :TRIGger:SEQuence:EDGE

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 593 Once you have acquired data with the :DIGitize comm

Pagina 550 - :TRIGger:SEQuence:FIND

594 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem AVERage DataAVERage data consists of the average of

Pagina 551 - :TRIGger:SEQuence:PATTern

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 595 voltage = [(data value - yreference) * yincrement]

Pagina 552 - :TRIGger:SEQuence:RESet

596 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem The setting of :WAVeform:BYTeorder (see page 597) a

Pagina 553 - :TRIGger:SEQuence:TIMer

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 597 :WAVeform:BYTeorder (see page 750)Command Syntax:WA

Pagina 554 - :TRIGger:SEQuence:TRIGger

598 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :WAVeform:COUNt (see page 750)Query Syntax:WAVeform

Pagina 555 - :TRIGger:SPI Commands

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 599 :WAVeform:DATA (see page 750)Query Syntax:WAVeform:

Pagina 556 - :TRIGger:SPI:CLOCk:SLOPe

6 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide Programming the Oscilloscope 50Referencing the IO Library 50Opening the Osci

Pagina 557 - :TRIGger:SPI:CLOCk:TIMeout

60 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide3 Getting Started

Pagina 558 - :TRIGger:SPI:FRAMing

600 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem ' and the actual waveform data followed by a n

Pagina 559 - :TRIGger:SPI:PATTern:DATA

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 601 :WAVeform:FORMat (see page 750)Command Syntax:WAVef

Pagina 560 - :TRIGger:SPI:PATTern:WIDTh

602 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :WAVeform:POINts (see page 750)Command Syntax:WAVef

Pagina 561 - :TRIGger:SPI:SOURce:CLOCk

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 603 See Also • "Introduction to :WAVeform Commands

Pagina 562 - :TRIGger:SPI:SOURce:DATA

604 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :WAVeform:POINts:MODE (see page 750)Command Syntax:

Pagina 563 - :TRIGger:SPI:SOURce:FRAMe

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 605 • :ACQuire:TYPE must be set to NORMal, AVERage, or

Pagina 564 - :TRIGger:TV Commands

606 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :WAVeform:PREamble (see page 750)Query Syntax:WAVef

Pagina 565 - :TRIGger:TV:LINE

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 607 See Also • "Introduction to :WAVeform Commands

Pagina 566 - :TRIGger:TV:MODE

608 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem ' TYPE : int16-0=NORMAL, 1 = PEAK DETECT, 2 =

Pagina 567 - :TRIGger:TV:POLarity

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 609 :WAVeform:SEGMented:COUNt (see page 750)Query Synta

Pagina 568 - :TRIGger:TV:SOURce

61 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide4Commands Quick ReferenceCommand Summary 62Syntax Elements 106

Pagina 569 - :TRIGger:TV:STANdard

610 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :WAVeform:SEGMented:TTAG (see page 750)Query Syntax

Pagina 570 - :TRIGger:UART Commands

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 611 :WAVeform:SOURce (see page 750)Command Syntax:WAVef

Pagina 571

612 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem ' WAVE_POINTS - Specifies the number of points

Pagina 572 - :TRIGger:UART:BASE

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 613 lngXReference = Preamble(6)sngYIncrement = Preamble

Pagina 573 - :TRIGger:UART:BAUDrate

614 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem varQueryResult = myScope.ReadIEEEBlock(BinaryType_U

Pagina 574 - :TRIGger:UART:BITorder

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 615 :WAVeform:SOURce:SUBSource (see page 750)Command Sy

Pagina 575 - :TRIGger:UART:BURSt

616 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :WAVeform:TYPE (see page 750)Query Syntax:WAVeform:

Pagina 576 - :TRIGger:UART:DATA

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 617 :WAVeform:UNSigned (see page 750)Command Syntax:WAV

Pagina 577 - :TRIGger:UART:IDLE

618 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :WAVeform:VIEW (see page 750)Command Syntax:WAVefor

Pagina 578 - :TRIGger:UART:PARity

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 619 :WAVeform:XINCrement (see page 750)Query Syntax:WAV

Pagina 579 - :TRIGger:UART:POLarity

62 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide4 Commands Quick Reference Command SummaryTable 2 Common (*) Commands Summar

Pagina 580 - :TRIGger:UART:QUALifier

620 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :WAVeform:XORigin (see page 750)Query Syntax:WAVefo

Pagina 581 - :TRIGger:UART:SOURce:RX

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 621 :WAVeform:XREFerence (see page 750)Query Syntax:WAV

Pagina 582 - :TRIGger:UART:SOURce:TX

622 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :WAVeform:YINCrement (see page 750)Query Syntax:WAV

Pagina 583 - :TRIGger:UART:TYPE

Commands by Subsystem 5Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 623 :WAVeform:YORigin (see page 750)Query Syntax:WAVefo

Pagina 584 - :TRIGger:UART:WIDTh

624 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide5 Commands by Subsystem :WAVeform:YREFerence (see page 750)Query Syntax:WAV

Pagina 585 - :TRIGger:USB Commands

625 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide6Commands A-ZA 625B 626C 627D 629E 631F 632G 633H 634I 634L 635M 636N 639

Pagina 586 - :TRIGger:USB:SOURce:DMINus

626 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide6 Commands A-Z • ":ACQuire:POINts" on page 184• ":ACQuire:S

Pagina 587 - :TRIGger:USB:SOURce:DPLus

Commands A-Z 6Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 627 • ":TRIGger:UART:BASE" on page 572• BAUDrate Comm

Pagina 588 - :TRIGger:USB:SPEed

628 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide6 Commands A-Z • CHANnel, ":TRIGger:FLEXray:CHANnel" on page 48

Pagina 589 - :TRIGger:USB:TRIGger

Commands A-Z 6Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 629 • CONDition, ":HWERegister:CONDition (Hardware Event C

Pagina 590 - :WAVeform Commands

Commands Quick Reference 4Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 63 n/a *OPT? (see page 123) <return_value> ::=

Pagina 591

630 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide6 Commands A-Z • ":TRIGger:CAN:PATTern:DATA:LENGth" on page 455•

Pagina 592

Commands A-Z 6Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 631 • ":DISPlay:SOURce" on page 231• ":DISPlay:V

Pagina 593

632 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide6 Commands A-Z F • FACTion Commands:• ":MTESt:RMODe:FACTion:MEASure&qu

Pagina 594

Commands A-Z 6Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 633 • ":TRIGger:I2S:PATTern:FORMat" on page 507• &quo

Pagina 595

634 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide6 Commands A-Z H • ":HARDcopy:AREA" on page 262• ":HARDcopy

Pagina 596

Commands A-Z 6Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 635 • ":SBUS:IIC:ASIZe" on page 407• ":TRIGger:I

Pagina 597 - :WAVeform:BYTeorder

636 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide6 Commands A-Z • ":TRIGger[:EDGE]:LEVel" on page 476• ":TRI

Pagina 598 - :WAVeform:COUNt

Commands A-Z 6Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 637 • ":SAVE:MASK[:STARt]" on page 387• ":MEASur

Pagina 599 - :WAVeform:DATA

638 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide6 Commands A-Z • ":MEASure:VAVerage" on page 325• ":MEASure

Pagina 600

Commands A-Z 6Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 639 • ":MTESt:AVERage:COUNt" on page 695• ":MTES

Pagina 601 - :WAVeform:FORMat

64 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide4 Commands Quick Reference *SRE <mask> (see page 129)*SRE? (see page 1

Pagina 602 - :WAVeform:POINts

640 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide6 Commands A-Z • ":FUNCtion:OFFSet" on page 251• "*OPC (Ope

Pagina 603

Commands A-Z 6Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 641 • ":TRIGger:LIN:PATTern:DATA:LENGth" on page 532•

Pagina 604 - :WAVeform:POINts:MODE

642 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide6 Commands A-Z • ":CHANnel<n>:PROBe:STYPe" on page 217• &q

Pagina 605

Commands A-Z 6Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 643 • REJect, ":TRIGger[:EDGE]:REJect" on page 477•

Pagina 606 - :WAVeform:PREamble

644 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide6 Commands A-Z • ":SAVE:FILename" on page 379• ":SAVE:IMAGe

Pagina 607 - #Vsteps =

Commands A-Z 6Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 645 • ":SBUS:UART:COUNt:RXFRames" on page 416• "

Pagina 608

646 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide6 Commands A-Z • ":SINGle" on page 172• SKEW, ":CHANnel<

Pagina 609 - :WAVeform:SEGMented:COUNt

Commands A-Z 6Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 647 • ":WAVeform:SOURce:SUBSource" on page 615• SOURc

Pagina 610 - :WAVeform:SEGMented:TTAG

648 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide6 Commands A-Z • ":CALibrate:STATus" on page 199• ":STATus&

Pagina 611 - :WAVeform:SOURce

Commands A-Z 6Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 649 • ":TIMebase:VERNier" on page 436• ":TIMebas

Pagina 612

Commands Quick Reference 4Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 65 :AUToscale:AMODE <value> (see page 142):AUT

Pagina 613

650 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide6 Commands A-Z • ":TRIGger:CAN:SOURce" on page 461• ":TRIGg

Pagina 614

Commands A-Z 6Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 651 • ":TRIGger:I2S:PATTern:DATA" on page 505• "

Pagina 615 - :WAVeform:SOURce:SUBSource

652 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide6 Commands A-Z • ":TRIGger:NREJect" on page 448• ":TRIGger:

Pagina 616 - :WAVeform:TYPE

Commands A-Z 6Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 653 • ":TRIGger:UART:TYPE" on page 583• ":TRIGge

Pagina 617 - :WAVeform:UNSigned

654 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide6 Commands A-Z • ":TRIGger:UART:BITorder" on page 574• ":TR

Pagina 618 - :WAVeform:VIEW

Commands A-Z 6Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 655 • VTIMe, ":MEASure:VTIMe" on page 332• VTOP, &q

Pagina 619 - :WAVeform:XINCrement

656 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide6 Commands A-Z • ":FUNCtion:WINDow" on page 259• ":TIMebase

Pagina 620 - :WAVeform:XORigin

657 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide7Obsolete and Discontinued CommandsObsolete commands are older forms of c

Pagina 621 - :WAVeform:XREFerence

658 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide7 Obsolete and Discontinued Commands :EXTernal:INPut (see page 668):EXTerna

Pagina 622 - :WAVeform:YINCrement

Obsolete and Discontinued Commands 7Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 659 :MEASure:THResholds (see page 682):MEA

Pagina 623 - :WAVeform:YORigin

66 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide4 Commands Quick Reference :OVLenable <mask> (see page 165):OVLenable?

Pagina 624 - :WAVeform:YREFerence

660 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide7 Obsolete and Discontinued Commands DiscontinuedCommandsDiscontinued comma

Pagina 625 - Commands A-Z

Obsolete and Discontinued Commands 7Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 661 DiscontinuedParametersSome previous os

Pagina 626

662 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide7 Obsolete and Discontinued Commands :CHANnel:LABel (see page 750)Command S

Pagina 627 - Commands A-Z 6

Obsolete and Discontinued Commands 7Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 663 :CHANnel2:SKEW (see page 750)Command S

Pagina 628

664 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide7 Obsolete and Discontinued Commands :CHANnel<n>:INPut (see page 750)

Pagina 629

Obsolete and Discontinued Commands 7Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 665 :CHANnel<n>:PMODe (see page 750)

Pagina 630

666 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide7 Obsolete and Discontinued Commands :DISPlay:CONNect (see page 750)Command

Pagina 631

Obsolete and Discontinued Commands 7Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 667 :ERASe (see page 750)Command Syntax:ER

Pagina 632

668 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide7 Obsolete and Discontinued Commands :EXTernal:INPut (see page 750)Command

Pagina 633

Obsolete and Discontinued Commands 7Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 669 :EXTernal:PMODe (see page 750)Command

Pagina 634

Commands Quick Reference 4Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 67 Table 4 :ACQuire Commands SummaryCommand Query Op

Pagina 635

670 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide7 Obsolete and Discontinued Commands :FUNCtion:SOURce (see page 750)Command

Pagina 636

Obsolete and Discontinued Commands 7Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 671 :FUNCtion:VIEW (see page 750)Command S

Pagina 637

672 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide7 Obsolete and Discontinued Commands :HARDcopy:DESTination (see page 750)Co

Pagina 638

Obsolete and Discontinued Commands 7Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 673 :HARDcopy:DEVice (see page 750)Command

Pagina 639

674 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide7 Obsolete and Discontinued Commands :HARDcopy:FILename (see page 750)Comma

Pagina 640

Obsolete and Discontinued Commands 7Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 675 :HARDcopy:FORMat (see page 750)Command

Pagina 641

676 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide7 Obsolete and Discontinued Commands :HARDcopy:GRAYscale (see page 750)Comm

Pagina 642

Obsolete and Discontinued Commands 7Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 677 :HARDcopy:IGColors (see page 750)Comma

Pagina 643

678 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide7 Obsolete and Discontinued Commands :HARDcopy:PDRiver (see page 750)Comman

Pagina 644

Obsolete and Discontinued Commands 7Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 679 :MEASure:LOWer (see page 750)Command S

Pagina 645

68 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide4 Commands Quick Reference :CALibrate:STARt (see page 198)n/a n/an/a :CALibr

Pagina 646

680 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide7 Obsolete and Discontinued Commands :MEASure:SCRatch (see page 750)Command

Pagina 647

Obsolete and Discontinued Commands 7Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 681 :MEASure:TDELta (see page 750)Query Sy

Pagina 648

682 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide7 Obsolete and Discontinued Commands :MEASure:THResholds (see page 750)Comm

Pagina 649

Obsolete and Discontinued Commands 7Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 683 :MEASure:TMAX (see page 750)Command Sy

Pagina 650

684 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide7 Obsolete and Discontinued Commands :MEASure:TMIN (see page 750)Command Sy

Pagina 651

Obsolete and Discontinued Commands 7Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 685 :MEASure:TSTArt (see page 750)Command

Pagina 652

686 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide7 Obsolete and Discontinued Commands :MEASure:TSTOp (see page 750)Command S

Pagina 653

Obsolete and Discontinued Commands 7Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 687 :MEASure:TVOLt (see page 750)Query Syn

Pagina 654

688 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide7 Obsolete and Discontinued Commands <value> ::= time in seconds of t

Pagina 655

Obsolete and Discontinued Commands 7Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 689 :MEASure:UPPer (see page 750)Command S

Pagina 656

Commands Quick Reference 4Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 69 :CHANnel<n>:OFFSet <offset>[suffix] (

Pagina 657 - Commands" on page 750)

690 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide7 Obsolete and Discontinued Commands :MEASure:VDELta (see page 750)Query Sy

Pagina 658

Obsolete and Discontinued Commands 7Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 691 :MEASure:VSTArt (see page 750)Command

Pagina 659

692 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide7 Obsolete and Discontinued Commands :MEASure:VSTOp (see page 750)Command S

Pagina 660

Obsolete and Discontinued Commands 7Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 693 :MTESt:AMASk:{SAVE | STORe} (see page

Pagina 661 - Parameters

694 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide7 Obsolete and Discontinued Commands :MTESt:AVERage (see page 750)Command S

Pagina 662 - :CHANnel:LABel

Obsolete and Discontinued Commands 7Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 695 :MTESt:AVERage:COUNt (see page 750)Com

Pagina 663 - :CHANnel2:SKEW

696 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide7 Obsolete and Discontinued Commands :MTESt:LOAD (see page 750)Command Synt

Pagina 664 - :CHANnel<n>:INPut

Obsolete and Discontinued Commands 7Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 697 :MTESt:RUMode (see page 750)Command Sy

Pagina 665 - :CHANnel<n>:PMODe

698 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide7 Obsolete and Discontinued Commands :MTESt:RUMode:SOFailure (see page 750)

Pagina 666 - :DISPlay:CONNect

Obsolete and Discontinued Commands 7Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 699 :MTESt:{STARt | STOP} (see page 750)Co

Pagina 667 - Command Syntax

Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 7 *OPT (Option Identification) 123*RCL (Recall) 124*RST (Reset) 125*SAV (Save)

Pagina 668 - :EXTernal:INPut

70 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide4 Commands Quick Reference Table 7 :DISPlay Commands SummaryCommand Query Op

Pagina 669 - :EXTernal:PMODe

700 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide7 Obsolete and Discontinued Commands :MTESt:TRIGger:SOURce (see page 750)Co

Pagina 670 - :FUNCtion:SOURce

Obsolete and Discontinued Commands 7Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 701 :PRINt? (see page 750)Query Syntax:PRI

Pagina 671 - :FUNCtion:VIEW

702 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide7 Obsolete and Discontinued Commands See Also • "Introduction to Root

Pagina 672 - :HARDcopy:DESTination

Obsolete and Discontinued Commands 7Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 703 :TIMebase:DELay (see page 750)Command

Pagina 673 - :HARDcopy:DEVice

704 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide7 Obsolete and Discontinued Commands :TRIGger:CAN:ACKNowledge (see page 750

Pagina 674 - :HARDcopy:FILename

Obsolete and Discontinued Commands 7Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 705 :TRIGger:LIN:SIGNal:DEFinition (see pa

Pagina 675 - :HARDcopy:FORMat

706 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide7 Obsolete and Discontinued Commands :TRIGger:TV:TVMode (see page 750)Comma

Pagina 676 - :HARDcopy:GRAYscale

707 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide8Error Messages-440, Query UNTERMINATED after indefinite response-430, Qu

Pagina 677 - :HARDcopy:IGColors

708 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide8 Error Messages -314, Save/recall memory lost-313, Calibration memory lost

Pagina 678 - :HARDcopy:PDRiver

Error Messages 8Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 709 -255, Directory full-254, Media full-253, Corrupt media-25

Pagina 679 - :MEASure:LOWer

Commands Quick Reference 4Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 71 :EXTernal:PROBe <attenuation> (see page 237

Pagina 680 - :MEASure:SCRatch

710 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide8 Error Messages -223, Too much data-222, Data out of range-221, Settings c

Pagina 681 - :MEASure:TDELta

Error Messages 8Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 711 -151, Invalid string data-150, String data error-148, Char

Pagina 682 - :MEASure:THResholds

712 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide8 Error Messages -112, Program mnemonic too long-109, Missing parameter-108

Pagina 683 - :MEASure:TMAX

Error Messages 8Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 713 +103, Write Error+104, Illegal Operation+105, Print Cancel

Pagina 684 - :MEASure:TMIN

714 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide8 Error Messages

Pagina 685 - :MEASure:TSTArt

715 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide9Status ReportingStatus Reporting Data Structures 718Status Byte Register

Pagina 686 - :MEASure:TSTOp

716 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide9 Status Reporting • To monitor an event, first clear the event; then, enab

Pagina 687 - :MEASure:TVOLt

Status Reporting 9Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 717 The bits in the status byte act as summary bits for the

Pagina 688

718 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide9 Status Reporting Status Reporting Data StructuresThe following figure sho

Pagina 689 - :MEASure:UPPer

Status Reporting 9Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 719 The status register bits are described in more detail in

Pagina 690 - :MEASure:VDELta

72 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide4 Commands Quick Reference :FUNCtion:OFFSet <offset> (see page 251):FU

Pagina 691 - :MEASure:VSTArt

720 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide9 Status Reporting The status registers picture above shows how the differe

Pagina 692 - :MEASure:VSTOp

Status Reporting 9Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 721 Status Byte Register (STB)The Status Byte Register is th

Pagina 693 - :MTESt:AMASk:{SAVE

722 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide9 Status Reporting The next program prints 0xD1 and clears bit 6 (RQS) and

Pagina 694 - :MTESt:AVERage

Status Reporting 9Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 723 Service Request Enable Register (SRE)Setting the Service

Pagina 695 - :MTESt:AVERage:COUNt

724 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide9 Status Reporting Trigger Event Register (TER)This register sets the TRG b

Pagina 696 - :MTESt:LOAD

Status Reporting 9Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 725 Output QueueThe output queue stores the oscilloscope- to

Pagina 697 - :MTESt:RUMode

726 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide9 Status Reporting Message QueueThe message queue contains the text of the

Pagina 698 - :MTESt:RUMode:SOFailure

Status Reporting 9Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 727 (Standard) Event Status Register (ESR)The (Standard) Eve

Pagina 699 - :MTESt:{STARt

728 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide9 Status Reporting (Standard) Event Status Enable Register (ESE)To allow an

Pagina 700 - :MTESt:TRIGger:SOURce

Status Reporting 9Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 729 Error QueueAs errors are detected, they are placed in an

Pagina 701

Commands Quick Reference 4Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 73 :FUNCtion:SPAN <span> (see page 258):FUNCti

Pagina 702 - Old Print Option: Is Now:

730 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide9 Status Reporting Operation Status Event Register (:OPERegister[:EVENt])Th

Pagina 703 - :TIMebase:DELay

Status Reporting 9Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 731 Operation Status Condition Register (:OPERegister:CONDit

Pagina 704 - :TRIGger:CAN:ACKNowledge

732 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide9 Status Reporting Arm Event Register (AER)This register sets bit 5 (Wait T

Pagina 705 - <value> ::= LIN

Status Reporting 9Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 733 Overload Event Register (:OVLRegister)The Overload Event

Pagina 706 - :TRIGger:TV:TVMode

734 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide9 Status Reporting Hardware Event Event Register (:HWERegister[:EVENt])This

Pagina 707 - Error Messages

Status Reporting 9Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 735 Hardware Event Condition Register (:HWERegister:CONDitio

Pagina 708

736 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide9 Status Reporting Mask Test Event Event Register (:MTERegister[:EVENt])The

Pagina 709 - Error Messages 8

Status Reporting 9Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 737 Clearing Registers and QueuesThe *CLS common command cle

Pagina 710

738 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide9 Status Reporting Status Reporting Decision Chartyesno Do you wantto do st

Pagina 711

739 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide10Synchronizing AcquisitionsSynchronization in the Programming Flow 740Bl

Pagina 712

74 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide4 Commands Quick Reference n/a :HARDcopy:PRINter:LIST? (see page 269)<lis

Pagina 713

740 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide10 Synchronizing Acquisitions Synchronization in the Programming FlowMost r

Pagina 714

Synchronizing Acquisitions 10Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 741 Blocking SynchronizationUse the :DIGitize com

Pagina 715 - Status Reporting

742 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide10 Synchronizing Acquisitions Polling Synchronization With TimeoutThis exam

Pagina 716

Synchronizing Acquisitions 10Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 743 myScope.WriteString ":OPERegister:CONDit

Pagina 717 - Status Reporting 9

744 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide10 Synchronizing Acquisitions Synchronizing with a Single-Shot Device Under

Pagina 718

Synchronizing Acquisitions 10Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 745 ' --------------------------------------

Pagina 719

746 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide10 Synchronizing Acquisitions Synchronization with an Averaging Acquisition

Pagina 720

Synchronizing Acquisitions 10Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 747 ' Save *ESE (Standard Event Status Enabl

Pagina 721 - Status Byte Register (STB)

748 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide10 Synchronizing Acquisitions

Pagina 722

749 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide11More About Oscilloscope CommandsCommand Classifications 750Valid Comman

Pagina 723

Commands Quick Reference 4Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 75 :MARKer:X2Position <position>[suffix] (see

Pagina 724 - Trigger Event Register (TER)

750 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide11 More About Oscilloscope Commands Command ClassificationsTo help you use

Pagina 725 - Output Queue

More About Oscilloscope Commands 11Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 751 Valid Command/Query Strings• "Prog

Pagina 726 - Message Queue

752 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide11 More About Oscilloscope Commands InstructionHeaderThe instruction header

Pagina 727

More About Oscilloscope Commands 11Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 753 • When the command/keyword is longer th

Pagina 728

754 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide11 More About Oscilloscope Commands For example, :CHANnel1:BWLimit ONCommon

Pagina 729 - Error Queue

More About Oscilloscope Commands 11Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 755 When a syntax definition specifies that

Pagina 730

756 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide11 More About Oscilloscope Commands • :OUTPut (see page 197)• :STARt (see p

Pagina 731 - Status Condition Register

More About Oscilloscope Commands 11Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 757 • :BWLimit (see page 235)• :IMPedance (

Pagina 732 - Arm Event Register (AER)

758 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide11 More About Oscilloscope Commands • :HWEenable (Hardware Event Enable Reg

Pagina 733

More About Oscilloscope Commands 11Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 759 • :SOURce (see page 315)• :STATistics (

Pagina 734

76 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide4 Commands Quick Reference :MEASure:DEFine DELay, <delay spec> (see pa

Pagina 735 - Event Condition Register

760 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide11 More About Oscilloscope Commands • :DELete (see page 352)• :ENABle (see

Pagina 736

More About Oscilloscope Commands 11Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 761 • [:STARt] (see page 376)• :RUN (see pa

Pagina 737 - Clearing Registers and Queues

762 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide11 More About Oscilloscope Commands • :RESet (see page 403)• :SYNC? (see pa

Pagina 738

More About Oscilloscope Commands 11Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 763 • :SETup (see page 426)• :TIME (see pag

Pagina 739 - Synchronizing Acquisitions

764 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide11 More About Oscilloscope Commands • :DURation (see page 464)• :GREatertha

Pagina 740 - Retrieve Results

More About Oscilloscope Commands 11Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 765 • :POLarity (see page 496)• :QUALifier

Pagina 741 - Blocking Synchronization

766 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide11 More About Oscilloscope Commands • :ID (see page 529)• :PATTern• :DATA (

Pagina 742

More About Oscilloscope Commands 11Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 767 • :SLOPe (see page 556)• :TIMeout (see

Pagina 743 - Synchronizing Acquisitions 10

768 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide11 More About Oscilloscope Commands • :DMINus (see page 586)• :DPLus (see p

Pagina 744

More About Oscilloscope Commands 11Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 769 • *RST (see page 125)• *SAV (see page 1

Pagina 745

Commands Quick Reference 4Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 77 :MEASure:OVERshoot [<source>] (see page 303

Pagina 746

770 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide11 More About Oscilloscope Commands The output statements in the examples a

Pagina 747

More About Oscilloscope Commands 11Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 771 Multiple commands may be any combinatio

Pagina 748

772 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide11 More About Oscilloscope Commands Query Return ValuesCommand headers imme

Pagina 749 - Query Return Values 772

More About Oscilloscope Commands 11Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 773 All Oscilloscope Commands Are Sequentia

Pagina 750 - Command Classifications

774 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide11 More About Oscilloscope Commands

Pagina 751 - Program Data

775 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12Programming ExamplesVISA COM Examples 776VISA Examples 809SICL Examples

Pagina 752

776 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples VISA COM Examples• "VISA COM Example in Visual

Pagina 753 - Compound Command Headers

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 777 '' If you are using a different signal or

Pagina 754 - Program Data Syntax Rules

778 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples ' There are also some additional initializatio

Pagina 755 - Command Tree

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 779 ' TRIGGER_EDGE_SLOPE - Sets the slope of the e

Pagina 756

78 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide4 Commands Quick Reference :MEASure:SHOW {1 | ON} (see page 314):MEASure:SHO

Pagina 757

780 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples '' NOTE! The DIGITIZE command is highly r

Pagina 758

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 781 Dim strPath As StringstrPath = "c:\scope\confi

Pagina 759

782 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples ' Query for risetime.myScope.WriteString "

Pagina 760

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 783 ' XINCREMENT : float64 - time difference betwe

Pagina 761

784 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples FormatNumber(sngYOrigin)+"V"+vbCrLfstrOut

Pagina 762

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 785 ' Query time at 1st rising edge on ch1.myScope

Pagina 763

786 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples myScope.FlushWrite (False)myScope.FlushReadEnd IfEx

Pagina 764

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 787 private static VisaComInstrument myScope;public sta

Pagina 765

788 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples myScope.DoCommand("*CLS"); // Clear the s

Pagina 766

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 789 * Extra()* ----------------------------------------

Pagina 767

Commands Quick Reference 4Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 79 :MEASure:VAMPlitude [<source>] (see page 32

Pagina 768

790 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples /* NOTE! The use of the DIGITIZE command is highly

Pagina 769 - Duplicate Mnemonics

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 791 byte[] DataArray;// Read setup string from file.Dat

Pagina 770

792 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples * obtain waveform data, you must specify the WAVEFO

Pagina 771

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 793 Console.WriteLine("Preamble TYPE: {0:e}",

Pagina 772 - Query Return Values

794 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples double fVdiv = 32 * fYincrement;double fOffset = fY

Pagina 773

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 795 // Clear the interface.m_IoObject.IO.Clear();}publi

Pagina 774

796 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples // Check for instrument errors.CheckForInstrumentEr

Pagina 775 - Programming Examples

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 797 }} while (strInstrumentError.ToString() != "+0

Pagina 776 - VISA COM Examples

798 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples VISA COM Example in Visual Basic .NETTo compile and

Pagina 777 - Programming Examples 12

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 799 ' do not need to be executed for the proper op

Pagina 778

8 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide :ACQuire:MODE 183:ACQuire:POINts 184:ACQuire:SEGMented:ANALyze 185:ACQuire:S

Pagina 779

80 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide4 Commands Quick Reference :MEASure:VRMS [<interval>][,][<source>

Pagina 780

800 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples ' The range value is eight times the volts per

Pagina 781

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 801 ' TIME_MODE (not executed in this example) - S

Pagina 782

802 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples Dim nBytes As Integer' SAVE_SYSTEM_SETUP - The

Pagina 783 - " + _

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 803 Console.WriteLine("Wrote screen image ({0} byt

Pagina 784

804 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples ' COUNT : int32-1andisalways1.' XINCREMEN

Pagina 785

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 805 '' Where:'' <header> = #8

Pagina 786 - VISA COM Example in C#

806 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples "c:\scope\data\waveform.csv.", nBytes)End

Pagina 787

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 807 Return fResultEnd FunctionPublic Function DoQueryVa

Pagina 788

808 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples ' If there is an error, print it.If strInstrum

Pagina 789

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 809 VISA Examples• "VISA Example in C" on pag

Pagina 790

Commands Quick Reference 4Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 81 Table 14 :MTESt Commands SummaryCommand Query Opt

Pagina 791

810 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples * This program illustrates most of the commonly-use

Pagina 792

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 811 * The commands in the extras function are shown for

Pagina 793

812 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples * The range value is ten times the time per divisio

Pagina 794

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 813 viPrintf(vi, ":TIMEBASE:MODE MAIN\n");}/*

Pagina 795

814 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples int i; /* Loop counter. */unsigned char setup_strin

Pagina 796

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 815 /* MEASURE - The commands in the MEASURE subsystem

Pagina 797

816 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples ** Once these parameters have been sent, the "

Pagina 798

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 817 * specified with the ":WAVEFORM:SOURCE" c

Pagina 799

818 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples * retrieve_waveform* ------------------------------

Pagina 800

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 819 ' Declare variables to hold numeric values ret

Pagina 801

82 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide4 Commands Quick Reference :MTESt:RMODe:FACTion:MEASure {{0 | OFF} | {1 | ON

Pagina 802

820 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples ' Get and display the device's *IDN? stri

Pagina 803

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 821 ' Open file for output.Dim hFile As LonghFile

Pagina 804

822 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples ' Analyze the captured waveform.' -------

Pagina 805

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 823 Debug.Print "Waveform points desired: " +

Pagina 806

824 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples FormatNumber(lngPoints, 0)Debug.Print "Wavefor

Pagina 807

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 825 err = viVPrintf(vi, command + vbLf, 0)If (err <&

Pagina 808

826 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples Private Function DoQueryNumbers(query As String) As

Pagina 809 - VISA Examples

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 827 Private Sub CheckInstrumentErrors()On Error GoTo Er

Pagina 810

828 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples End SubVISA Example in C#To compile and run this ex

Pagina 811

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 829 {try{oscp = newVisaInstrument("USB0::2391::595

Pagina 812

Commands Quick Reference 4Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 83 :MTESt:SOURce <source> (see page 369):MTESt

Pagina 813

830 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples */strResults = oscp.DoQueryString("*IDN?"

Pagina 814

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 831 * for reference purposes only. To execute these com

Pagina 815

832 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples * communication with the computer interrupts data a

Pagina 816

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 833 // Read setup string from file.DataArray = File.Rea

Pagina 817

834 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples * parameters for the waveform data prior to sending

Pagina 818 - VISA Example in Visual Basic

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 835 double fPoints = fResultsArray[2];Console.WriteLine

Pagina 819

836 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples double fOffset = fYorigin;double fSdiv = fPoints *

Pagina 820

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 837 }public void DoCommand(string strCommand){// Send t

Pagina 821

838 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples public double DoQueryValue(string strQuery){// Send

Pagina 822

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 839 strInstrumentError = VisaGetResultString();if (strI

Pagina 823

84 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide4 Commands Quick Reference Table 16 :SAVE Commands SummaryCommand Query Opti

Pagina 824

840 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples fResultsArray);CheckVisaStatus(nViStatus);return fR

Pagina 825

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 841 public void CheckVisaStatus(int nViStatus){// If VI

Pagina 826

842 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples 6 Build and run the program.For more information, s

Pagina 827

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 843 Private Shared Sub Initialize()Dim strResults As St

Pagina 828 - VISA Example in C#

844 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples oscp.DoCommand(":TRIGger:EDGE:SLOPe POSitive&q

Pagina 829

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 845 ' as it will ensure that sufficient data is av

Pagina 830

846 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples ' Read setup string from file.DataArray = File

Pagina 831

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 847 ' parameters for the waveform data prior to se

Pagina 832

848 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples Dim fCount As Double = fResultsArray(3)Console.Writ

Pagina 833

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 849 Console.WriteLine("Offset = {0:f}", fOffs

Pagina 834

Commands Quick Reference 4Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 85 :SAVE:WAVeform[:STARt] [<file_name>] (see p

Pagina 835

850 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples ' Check for instrument errors (another command

Pagina 836

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 851 Dim fResults As DoublefResults = VisaGetResultValue

Pagina 837

852 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples Console.Write(strInstrumentError)End IfLoop While s

Pagina 838

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 853 ' Number of bytes returned from instrument.&ap

Pagina 839

854 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples If m_nResourceManager <> 0 Thenvisa32.viClose

Pagina 840

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 855 SICL Examples• "SICL Example in C" on pag

Pagina 841

856 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples * Edit the DEVICE_ADDRESS line to specify the addre

Pagina 842

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 857 /* Clear the interface. */iclear(id);iremote(id);}i

Pagina 843

858 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples */iprintf(id, ":AUTOSCALE\n");/* CHANNEL_

Pagina 844

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 859 iprintf(id, ":RUN\n");iprintf(id, ":

Pagina 845

86 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide4 Commands Quick Reference :SBUS:I2S:BASE <base> (see page 406):SBUS:I

Pagina 846

860 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples /** analyze* --------------------------------------

Pagina 847

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 861 itimeout(id, 30000);printf("Transferring image

Pagina 848

862 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples * get_waveform* -----------------------------------

Pagina 849

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 863 printf("Preamble TYPE: %e\n", preamble[1]

Pagina 850

864 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples {FILE *fp;fp = fopen("c:\\scope\\data\\wave.da

Pagina 851

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 865 '' Agilent SICL Example in Visual Basic&a

Pagina 852

866 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples ' --------------------------------------------

Pagina 853

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 867 ' Or, configure the settings with individual c

Pagina 854

868 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples Debug.Print "Setup bytes restored: " + CS

Pagina 855 - SICL Examples

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 869 Close hFile ' Close file.MsgBox "Screen i

Pagina 856

Commands Quick Reference 4Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 87 Table 18 :SYSTem Commands SummaryCommand Query Op

Pagina 857

870 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples ' Set up output file:strPath = "c:\scope\

Pagina 858

Programming Examples 12Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 871 Call ivprintf(id, command + " ")' Wr

Pagina 859

872 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide12 Programming Examples End FunctionPrivate Function DoQueryIEEEBlock_Bytes

Pagina 860

Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 873 IndexSymbols+9.9E+37, infinity representation, 772+9.9E+37, measurement er

Pagina 861

874 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's GuideIndex calibrate temperature, 201calibrate time, 202CAN, 454CAN acknowledge,

Pagina 862

IndexAgilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 875 DATA commands, 629data conversion, 594data displayed, 226data format

Pagina 863

876 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's GuideIndex example code, :WAVeform:DATA, 599example code, :WAVeform:POINts, 603e

Pagina 864 - SICL Example in Visual Basic

IndexAgilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 877 HWERegister[:EVENt] (Hardware Event Event Register), 152, 734II/O sof

Pagina 865

878 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's GuideIndex low-pass filter used to limit bandwidth, 206, 235LRN (Learn Device Se

Pagina 866

IndexAgilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 879 non-volatile memory, label list, 229normal acquisition type, 177, 593

Pagina 867

88 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide4 Commands Quick Reference :TIMebase:RANGe <range_value> (see page 433

Pagina 868

880 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's GuideIndex probe attenuation factor for selected channel, 213PROBe commands, 641

Pagina 869

IndexAgilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 881 SEGMented commands, 645segmented waveform save option, 393segments, a

Pagina 870

882 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's GuideIndex TER (Trigger Event Register), 175, 724termination conditions, mask te

Pagina 871

IndexAgilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 883 trigger, SPI frame source, 563trigger, SPI framing, 558trigger, SPI p

Pagina 872

884 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's GuideIndex waveform peak-to-peak vertical value measured, 329waveform period, 30

Pagina 873 - Numerics

Commands Quick Reference 4Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 89 :TRIGger:MODE <mode> (see page 447):TRIGger

Pagina 874

Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 9 :DISPlay:SOURce 231:DISPlay:VECTors 232:EXTernal Trigger Commands 233:EXTern

Pagina 875

90 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide4 Commands Quick Reference Table 21 :TRIGger:CAN Commands SummaryCommand Que

Pagina 876

Commands Quick Reference 4Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 91 :TRIGger:CAN:SOURce <source> (see page 461)

Pagina 877 - , 251, 254

92 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide4 Commands Quick Reference Table 23 :TRIGger:EBURst Commands SummaryCommand

Pagina 878

Commands Quick Reference 4Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 93 Table 25 :TRIGger:FLEXray Commands SummaryCommand

Pagina 879 - function, 251, 254

94 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide4 Commands Quick Reference Table 26 :TRIGger:GLITch Commands SummaryCommand

Pagina 880

Commands Quick Reference 4Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 95 Table 27 :TRIGger:I2S Commands SummaryCommand Que

Pagina 881

96 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide4 Commands Quick Reference :TRIGger:I2S:SOURce:DATA <source> (see page

Pagina 882

Commands Quick Reference 4Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 97 :TRIGger:IIC:TRIGger:QUALifier <value> (see

Pagina 883

98 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide4 Commands Quick Reference :TRIGger:LIN:SOURce <source> (see page 536)

Pagina 884

Commands Quick Reference 4Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 99 Table 31 :TRIGger:SEQuence Commands SummaryComman

Comentarios a estos manuales