Introduction
Agilent 4155C and 4156C
Basic Functions
• Set measurement and/or stress
conditions
• Control measurement and/or stress
execution
• Perform arithmetic calculations
• Display measured and calculated
results on the LCD display
• Perform graphical analysis
• Store and recall measurement
setups, and measurement and
graphical display data
• Dump to printers or plotters for
hardcopy output
• Perform measurement and analysis
with built-in instrument BASIC
• Self test, Auto calibration
Configuration
The 4155C and 4156C both come
standard with I/CV 2.1 Lite
automation software. A PC-based
instrument controller with I/CV Lite
preinstalled and an Agilent 82357A
USB/GPIB interface are also included
with the standard configuration. You
have the option of deleting the
controller and cable from your order,
but I/CV Lite is always included with
HRSMU: High Resolution SMU
(1fA/2µV to 100mA/100V)
MPSMU: Medium Power SMU
(10fA/2µV to 100mA/100V)
HPSMU: High Power SMU
(10fA/2µV to 1A/200V)
VMU: Voltage Monitor Unit
(0.2µV resolution in differential
mode)
VSU: Voltage Source Unit
PGU: Pulse Generator Unit (1 channel)
GNDU: Ground Unit
1
Minimum number of installable MPSMU or
PGU is two.
2
Accuracy not guaranteed. Minimum
guaranteedresolution is 1fA at 10pA range.
4155C
4xMPSMU
2xVMU 2xVMU
2xVSU 2xVSU
I/CV 2.1 Lite I/CV 2.1 Lite
4156C
4xHRSMU
41501B (Optional)
GNDU
2xPGU (Option)
1
HPSMU (Option) or
2xMPSMU (Option)
1
Agilent 4155C Semiconductor
Parameter Analyzer
Agilent 4156C Precision Semiconductor
Parameter Analyzer
Data Sheet
SMU: Source Monitor Unit
Display resolution: 6 digits at each
current range (0.01fA display resolu-
tion at 10pA range)
2
both instruments. If you want the full
version of I/CV 2.1, you can request
the E5240BU upgrade kit when you
order a 4155C or 4156C. For more
information about the differences
between I/CV 2.1 Lite and I/CV 2.1,
please refer to the Agilent I/CV 2.1
Technical Overview, publication
number 5988-8474EN.
Standard PC-based controller
and USB/GPIB interface
S1
S
Vista de pagina 0
1 2 3 4 5 6 ... 11 12

Indice de contenidos

Pagina 1 - Parameter Analyzer

IntroductionAgilent 4155C and 4156CBasic Functions• Set measurement and/or stressconditions• Control measurement and/or stressexecution• Perform arith

Pagina 2 - Hardware

I/CV 2.1 LiteOverviewAgilent I/CV 2.1 Lite providesautomated test solutions for semi-conductor characterization. It sup-ports the Agilent 4155C and 41

Pagina 3 - VMU (Voltage Monitor Unit)

Computer System RequirementsOperating SystemMicrosoft Windows 2000Professional or XP Professionalwith Service Pack 1CPU300 MHz Pentium II-class (500

Pagina 4 - HPSMU Measurement

For more information about Agilent and itsproducts, go to www.agilent.com.For more information about Agilent Technologiessemiconductor test products,

Pagina 5 - Specifications:

HardwareSpecification ConditionThe “supplemental” information and“typical” entries in the following specifi-cations are not warranted, but provide

Pagina 6 - Functions

VMU Measurement Range, Resolution,and Accuracy:Voltage Meas. Meas.Range Reso. Accuracy±2V 2µV ±(0.02%+200µV)±20V 20µV ± (0.02%+1mV)VMU Supplemental In

Pagina 7

Agilent 41501B SMU and Pulse Generator ExpanderHPSMU (High Power SMU) SpecificationsVoltage Range, Resolution, and Accuracy (HPSMU)Voltage Set. Set. M

Pagina 8

PGU (Pulse Generator Unit)SpecificationsModes: Pulse or constantAmplitude: 0Vp-p to 40Vp-pWindow: -40.0V to +40.0VMaximum current: ±100mA ±200mA (pu

Pagina 9 - Accessory

Capacitance Calculation Accuracy (Supplemental Data)Accuracy is derived from the current range, voltage range, capacitance measure-ment and leakage cu

Pagina 10 - Automation Software

A condition to stop the sampling can be defined.Sampling interval setting accuracy(supplemental data): 0.5% + 10µs (sampling interval £480µs) 0.5

Pagina 11

Data StorageMass storage device: Built-in 3.5-inch floppy disk driveMedia: 3.5-inch 2HD or 2DD disketteFormat type: HP LIF and DOSUser area: 1.44Mbyt

Pagina 12

AltitudeOperating: 0 to 2,000 m (6,561 ft)Storage: 0 to 4,600 m (15,091 ft)Power requirement90V to 264V, 47 to 63 HzMaximum VA4155C and 4156C: 450VA41