Specifications and Regulatory Information
Agilent 83433A Specifications and Characteristics
EMI Radiated and conducted emissions are
in compliance with the requirements of
CISPR Publication 11, Class A and
immunity in compliance with
IEC 61326-1
a. AC coupled.
b. Input power greater than +10 dBm may cause modulated optical output power to exceed Class I level.
c. Class IIIB laser output.
d. Wavelength adjustment disabled.
e. Average power with internal laser modulated with 2
31
-1 PRBS.
f. Measured with 1 V pk-pk data input signal and 2
31
-1 PRBS on an 83480A, 83485B with OC-192 filter.
g. Applies over the temperature range 0
°
C to 30
°
C.
h. Panda polarization-maintaining fiber with slow axis aligned to key.
i. Standard instrument has FC/PC adapters.Other adapters available as options.