Agilent Technologies 8922S Guía de usuario Pagina 76

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 100
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 75
62
System Specifications
Phase and Frequency Measurement Specifications
Phase and Frequency Measurement Specifications
After one timeslot, 577 µs from an isolated hop trigger in the GSM/DCS/PCS
frequency bands.
Input frequency setting range: ±10 kHz
Input level setting range: ±3 dB
RMS phase error accuracy: 1
0
rms
RMS phase error measurement versus measured value
Peak phase error accuracy: 4
0
peak
Frequency error accuracy: ± (22 Hz + reference accuracy), for
normal bursts
Supplemental Characteristics
Frequency error accuracy: ± (9 Hz + reference accuracy) for normal
bursts
± (18 Hz + reference accuracy)
for RACHs
012345
Measurement Result (Deg rms)
0.6
0.5
0.3
0.2
0
Uncertainty (Deg rms)
0.4
0.1
0.5 1.5 2.5 3.5 4.5 5.5
Specified - Typical
Vista de pagina 75
1 2 ... 71 72 73 74 75 76 77 78 79 80 81 ... 99 100

Comentarios a estos manuales

Sin comentarios