Agilent Technologies DP111 Especificaciones Pagina 194

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 452
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 193
Internal Battery Section 5 Maintenance
194 3BSE036351-510 A
To exchange the internal battery:
1. Using a blade screwdriver, release the captive screw from the PM8xx and
remove the right-hand cover.
2. Identify and remove the internal battery.
3. When power is re-established, ensure that the B(attery) LED is illuminated
4. Replace the PM8xx right-hand cover and tighten the screw.
5. Dispose of the run-down Lithium battery in an approved manner.
Insert a serviceable battery and check that battery polarity and orientation are
correct, according to the marking on the housing.
Figure 64. Internal Battery Location – here shown with PM860
F
R
P
B
INIT
PM860
Tx
Rx
CN1
CN2
COM3
COM4
+
Tx
Tx
Tx
Rx
Rx Rx
battery
Internal
Vista de pagina 193
1 2 ... 189 190 191 192 193 194 195 196 197 198 199 ... 451 452

Comentarios a estos manuales

Sin comentarios