Agilent E6432A Microwave Synthesizer Users Guide 3-57
Soft Front Panel Help
Configuration Dialog Box
Allow IF and I/Q Concurrent Operation (Options UNG
and 300 Only)
Allow IF and I/Q Concurrent Operation, available from the
Configuration Dialog Box, is used to allow both the 300 MHz IF In port
(Option 300 Only) and the I/Q Input ports (Option UNG Only) to be
used concurrently. This allows the output of the I/Q modulator circuitry
to be summed with the 300 MHz IF In signal. This summed signal is
delivered to the IF input of the first mixer.
The IF Upconverter Calibration Attenuator, available from the
Configuration Dialog Box, can be used to set the signal level delivered
to the IF input of the first mixer.
Related Topics
Soft Front Panel Help
Configuration Dialog Box Controls
IF Upconverter Calibration Attenuator