29
www.agilent.com/find/n4906
• Excellent price/performance ratio
• Variable bit rates up to 3.6 or 12.5 Gb/s
• < 25 ps transition time
• < 50 mV pp input sensitivity
• Fast eye mask measurement for pass/fail testing (Option 101)
• True differential data generation and analysis capability
• Enhanced measurement suite (Option 101)
• Integrated clock data recovery (Option 102)
• Small form factor saves bench or rack space
• LAN, USB, GPIB for remote control
• Compatibility with existing remote commands, e.g. Agilent 71612,
86130A Series and N4900 Series
• Applications: Manufacturing test, telecom transceivers such as
SONET/SDH Fibre Channel, 10GbE, XFP/XFI, PON-OLT’s and high-
speed serial computer buses
The serial BERT N4906B is a general-purpose bit error ratio tester,
designed for testing high-speed digital communication components and
systems. It is ideal for cost-effective manufacturing and telecom device
testing. It offers a 3.6 or 12.5 Gb/s pattern generator and error detector
with excellent price/performance ratio.
Transition times < 25 ps allow precise measurements. The analyzer can be
configured with CDR to test clockless interfaces and with true differential
inputs to test LVDS and other differential interfaces.
ThecompactsizeoftheN4906Bsavesrackspace;LAN,USBandGPIB
interfaces allow smooth integration into automated test environments.
For bench users the N4906B serial BERT offers an intuitive user interface
with state-of-the-art Windows-XP based touch-screen.
Deeper insight into the device’s performance can be obtained with the
enhanced measurement suite. It offers many valuable signal analysis
tools, such as BERT scan (so-called bathtub curves) with total jitter and
its separation into RJ and DJ, eye contours, spectral jitter decomposition
and more.
Specifications
Pattern generator
• Operation range:
• 9.5 to 12.5 Gb/s (Option 012)
•
150 Mb/s to 12.5 Gb/s (Option 102)
• 150 Mb/s to 3.6 Gb/s (Option 003)
• Data output: 1, differential or single-ended
• Output amplitude: 0.10 to 1.8 V in 5 mV steps
• Jitter: 9 ps pp typical
• Transition time: < 25 ps (10 to 90 % and ECL levels)
• Cross point adjust: 20 to 80 %
Pattern
• PRBS 2
n
– 1, n = 7, 10, 11, 15, 23, 31
• User-definable memory: 32 Mbit
Error detector
• Operation range:
• 9.5 to 12.5 Gb/s (Option 012)
• 150 Mb/s to 3.6 Gb/s (Option 003)
• 150 Mb/s to 12.5 Gb/s (Option 102)
• Data input: 1, single-ended or differential (Option 101 or 003)
• Delay adjust: 1.5 ns
• Clock data recovery (Option 102):
• 1.058 to 1.6 Gb/s: Loop bandwidth 1 MHz typ.
• 2.115 to 3.2 Gb/s: Loop bandwidth 2 MHz typ.
• 4.23 to 6.4 Gb/s: Loop bandwidth 4 MHz typ.
• 9.9 to 10.9 Gb/s: Loop bandwidth 8 MHz typ.
• Sensitivity: < 50 mV
Measurements
• BER
• Fast eye mask measurement with pass/fail (Option 101)
• BERT scan with RJ/DJ separation (Option 101)
• Fast total jitter (Option 101)
• Spectral jitter decomposition (Option 101)
• Eye contour (Option 101)
• Output level (Option 101)
• Error location capture (Option 101)
Agilent N4906B-003 (3.6 Gb/s) & N4906B-012 (12.5 Gb/s) Serial BERT