Agilent X-Series SignalAnalyzerThis help file provides documentation for the followingX-Series Analyzers:PXASignal Analyzer N9030AMXASignal Analyzer
Table Of ContentsLegacy Products 252Description 252C2 [two] (A Minus B Into A) 253Syntax 253Legacy Products 253Description 253CA (Couple Attenuation)
3 Programming the AnalyzerList of Supported SCPI CommandsU:UNIT:POWer "Y Axis Unit" on page 533100 Remote Language Compatibility Measuremen
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRestartMore InformationThe Restart function first aborts the current sweep/measurement as
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveSaveThe Save menu lets you choose what you want to save and where you want to save it.
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveExample MMEM:STOR:STATe "MyStateFile.state"This stores the current instrumen
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveThe Listed beloware the functions of the various fields in the dialog, and the corresp
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSavedefault path for this type of file and remembers the last path you used to save this t
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveMode AllNotes Brings up Save As dialog for saving a State Save TypeInitial S/W Revisio
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveWhile the save is being performed, the floppy icon appears briefly in the Meas bar.Fil
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveThis key corresponds to the icon of a folder with the "*" that is in the too
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveThe Listed beloware the functions of the various fields in the dialog, and the corresp
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSavedefault path for this type of file and remembers the last path you used to save this t
3 Programming the AnalyzerIEEE 488.2 Common CommandsIEEE 488.2 Common CommandsThe instrument supports the following subset of IEEE 488.2 Common Comma
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveMode AllNotes Brings up Save As dialog for saving a State Save TypeInitial S/W Revisio
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveWhile the save is being performed, the floppy icon appears briefly in the Meas bar.Fil
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveThis key corresponds to the icon of a folder with the "*" that is in the too
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveThe Listed beloware the functions of the various fields in the dialog, and the corresp
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSavedefault path for this type of file and remembers the last path you used to save this t
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveMode AllNotes Brings up Save As dialog for saving a State Save TypeInitial S/W Revisio
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveWhile the save is being performed, the floppy icon appears briefly in the Meas bar.Fil
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveThis key corresponds to the icon of a folder with the "*" that is in the too
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveThe Listed beloware the functions of the various fields in the dialog, and the corresp
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSavedefault path for this type of file and remembers the last path you used to save this t
3 Programming the AnalyzerIEEE 488.2 Common CommandsCondition message “Align Now, RF required” is generated, and bits 11 and 12 are set in the Status
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveMode AllNotes Brings up Save As dialog for saving a State Save TypeInitial S/W Revisio
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveWhile the save is being performed, the floppy icon appears briefly in the Meas bar.Fil
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveThis key corresponds to the icon of a folder with the "*" that is in the too
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveOR“(empty)" if no prior save operation has been performed to this register.Initia
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveRegister 1 thru Register 16Selecting any one of these register menu keys causes the St
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveAlthough these 16 registers are the only registers available from the front panel, the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveAfter the save completes, the corresponding register menu key annotation is updated wi
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveExample *SAV 1Range 1–16 from front panel, 1–128 from SCPIReadback Date and time with
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveOR“(empty)" if no prior save operation has been performed to this register.Initia
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveRegister 1 thru Register 16Selecting any one of these register menu keys causes the St
3 Programming the AnalyzerIEEE 488.2 Common CommandsWhile Align Now, All is performing the alignment, bit 0 in the Status Operation register is set.C
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveAlthough these 16 registers are the only registers available from the front panel, the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveAfter the save completes, the corresponding register menu key annotation is updated wi
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveExample *SAV 1Range 1–16 from front panel, 1–128 from SCPIReadback Date and time with
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveOR“(empty)" if no prior save operation has been performed to this register.Initia
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveRegister 1 thru Register 16Selecting any one of these register menu keys causes the St
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveAlthough these 16 registers are the only registers available from the front panel, the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSave:MMEMory:REGister:STATe:LABel? <reg number>Example :MMEM:REG:STAT:LAB 1,”my labe
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSavesettings, even though they are outside of the Mode’s state, because they are needed to
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveBoth single and double quotes are supported for any filename parameter over remote.Aft
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveAmplitude CorrectionPressing this key selects Amplitude Corrections as the data type t
3 Programming the AnalyzerIEEE 488.2 Common CommandsKey PathNo equivalent key. Related key System, Show Errors, Clear Error QueueRemote Command*CLSEx
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveLine# Type of field Example Notes“Amplitude Correction”2 File Description (in quotes)
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveLines 2 through 5 can be empty but must appear in the file. Lines 6 through 11 are op
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveA.02.06,N9020AP13 EA3 UK6,01Frequency Unit,MHzAntenna Unit,dBuV/mFrequency Interpolati
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSavePreset Not part of a Preset, but is reset to Correction 1 by Restore Input/Output Defa
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveKey PathSave, Data, Amplitude CorrectionPreset Not part of a Preset, but is reset to C
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveCouplings When you select which trace to save, it makes that trace the current trace,
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSave• Sweep Time• Start Frequency• Stop Frequency• Average Count (actual; not the limit fo
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSave• RBW Filter BW: 3dB, 6dB, Noise, Impulse• Sweep Type: Swept, FFT• PreAmp State: On, O
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveAverage Count 0Average Type Power(RMS)RBW 51000RBW Filter GaussianRBW Filter BW 3dBVBW
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveY Axis Unit dBmDATA1.6009301E+07 4.82047E+011.6018694E+07 4.69737E+011.6028087E+07 4.8
3 Programming the AnalyzerIEEE 488.2 Common CommandsStandard Event Status Register QueryQueries and clears the standard event status event register.
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveNotes auto returnCouplings When you select which trace to save, it makes that trace th
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSavecurrently selected trace, selected in this menu or in the Trace/Det, Import Data, Reca
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveKey PathSave, Data, TraceNotes auto returnCouplings When you select which trace to sav
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveSelect TraceThese softkeys let you pick which Trace to save. Once selected, the key re
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveThis menu is the same as the Select Trace menu under Trace. The trace selected on that
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveLimits File ContentsLimits may be exported into a data file with a .csv extension. The
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveIf the sign of the margin is inappropriate for the limit type (for example a positive
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveLimit SelectionThese keys let you pick which Limit Line to save. Once selected, the ke
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveLimit SelectionThese keys let you pick which Limit Line to save. Once selected, the ke
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSavemessage is generatedIf a save of Spectrogram results is requested and the Spectrogram
3 Programming the AnalyzerIEEE 488.2 Common CommandsOperation CompleteThe *OPC command sets bit 0 in the standard event status register (SER) to “1”
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveMeas-urementResultSwept SAA.01.40_R0017 N9020A526 B25 PFR P26EA31Result Type MarkerTab
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaverangeRF Coupling ACFFT Width 411900Ext Ref 10000000Input RFRF Calibrator OffAttenuatio
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSave39 Fixed 3 InverseTime4.0000E-+01–30.0-5Off 0.0000E-+000 None10 Normal 3 Frequen-cy1.1
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveThen the Meas Results file, when opened, would show the header data (the same as for t
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveMeasurementResultSwept SAA.01.40_R0017 N9020A526 B25 PFR P26 EA3 1Result Type Peak Tab
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveRef Level Offset 0External Gain 0X Axis Units HzY Axis Units dBmPeak Threshold –85Peak
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveSpectrogramThis section discusses the Spectrogram Results file format. The Spectrogr
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveFor the purpose of this example, we have set the Average/Hold Number to 10, thus we ha
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveResult Type SpectrogramDRD EA3 EDP EMC EP1 ERC ESCESP EXM FSA HBA K03 LFE MPBP03 P08 P
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveResult Type SpectrogramRef Level Offset 0External Gain 0Trace Type ClearwriteDetector
3 Programming the AnalyzerIEEE 488.2 Common CommandsQuery Instrument OptionsReturns a string of all the installed instrument options. It is a comma s
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSave5999984490 –74.027120795999984515 –73.57213005ooo6000009315 –75.91831036000009340 –79.
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveMeasurement ResultsPressing this key selects Meas Results as the data type to be expor
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveImagine that, at the point where a Marker Table Meas Result is requested, the followin
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveStart Frequency 10000000Stop Frequency 26500000-000Average Count 0Average Type LogPowe
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveMKR MODE TR-CSCL X Y FUNC-TIONFUNC-TIONWIDTHFUNC-TIONVALUEFUNC-TIONUNIT1 Normal 1 Freq
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveThe metadata header is very similar to the metadata used in the trace data .csv files.
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSave• Peak Readout (All|AboveDL|BelowDL)• Peak Sort (Freq|Amptd)These fields are then foll
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveRF Coupling ACFFT Width 411900Ext Ref 10000000Input RFRF Calibrator OffAttenuation 10R
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSave15 9.5140E+05 –60.8916 9.5920E+05 –60.9017181920SpectrogramThis section discusses the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveTraces that have not yet been filled in the Spectrogram display are empty; there is no
3 Programming the AnalyzerIEEE 488.2 Common Commands*RST (Remote Command Only)*RST is equivalent to :SYST:PRES;:INIT:CONT OFF, which is a Mode Preset
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveResult Type SpectrogramSwept SAA.11.00.01 N9020A503 508 513 526 ALL ALV B1C B1XB25 B2X
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveResult Type SpectrogramInput RFRF Calibrator OffAttenuation 14Ref Level Offset 0Extern
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSave5999984415 –80.981978825999984440 –80.981978795999984465 –75.831421325999984490 –74.02
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveMeasurement ResultsPressing this key selects Meas Results as the data type to be expor
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveImagine that, at the point where a Marker Table Meas Result is requested, the followin
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveStart Frequency 10000000Stop Frequency 26500000-000Average Count 0Average Type LogPowe
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveMKR MODE TR-CSCL X Y FUNC-TIONFUNC-TIONWIDTHFUNC-TIONVALUEFUNC-TIONUNIT1 Normal 1 Freq
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveThe metadata header is very similar to the metadata used in the trace data .csv files.
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSave• Peak Readout (All|AboveDL|BelowDL)• Peak Sort (Freq|Amptd)These fields are then foll
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveRF Coupling ACFFT Width 411900Ext Ref 10000000Input RFRF Calibrator OffAttenuation 10R
3 Programming the AnalyzerIEEE 488.2 Common CommandsService Request EnableThis command enables the desired bits of the service request enable registe
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSave15 9.5140E+05 –60.8916 9.5920E+05 –60.9017181920SpectrogramThis section discusses the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveTraces that have not yet been filled in the Spectrogram display are empty; there is no
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveResult Type SpectrogramSwept SAA.11.00.01 N9020A503 508 513 526 ALL ALV B1C B1XB25 B2X
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveResult Type SpectrogramInput RFRF Calibrator OffAttenuation 14Ref Level Offset 0Extern
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSave5999984415 –80.981978825999984440 –80.981978795999984465 –75.831421325999984490 –74.02
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveMeasurement ResultsPressing this key selects Meas Results as the data type to be expor
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveImagine that, at the point where a Marker Table Meas Result is requested, the followin
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveStart Frequency 10000000Stop Frequency 26500000-000Average Count 0Average Type LogPowe
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveMKR MODE TR-CSCL X Y FUNC-TIONFUNC-TIONWIDTHFUNC-TIONVALUEFUNC-TIONUNIT1 Normal 1 Freq
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveThe metadata header is very similar to the metadata used in the trace data .csv files.
Table Of ContentsDescription 262CLRW (Clear Write) 263Syntax 263Legacy Products 263Description 263CONTS (Continuous Sweep) 265Syntax 265Legacy Product
3 Programming the AnalyzerIEEE 488.2 Common CommandsRemote Command*TRGExample *TRG Triggers the instrument to take a sweep or start a measurement, de
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSave• Peak Readout (All|AboveDL|BelowDL)• Peak Sort (Freq|Amptd)These fields are then foll
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveRF Coupling ACFFT Width 411900Ext Ref 10000000Input RFRF Calibrator OffAttenuation 10R
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSave15 9.5140E+05 –60.8916 9.5920E+05 –60.9017181920SpectrogramThis section discusses the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveTraces that have not yet been filled in the Spectrogram display are empty; there is no
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveResult Type SpectrogramSwept SAA.11.00.01 N9020A503 508 513 526 ALL ALV B1C B1XB25 B2X
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveResult Type SpectrogramInput RFRF Calibrator OffAttenuation 14Ref Level Offset 0Extern
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSave5999984415 –80.981978825999984440 –80.981978795999984465 –75.831421325999984490 –74.02
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveSave As . . .When you press “Save As”, the analyzer brings up a Windows dialog and a m
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveFor all of the Limit Data Files:My Documents\<mode name>\data\limitsFor all of t
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveKey PathSave, DataMode AllNotes The key location is mode-dependent and will vary.Bring
3 Programming the AnalyzerRemote Measurement FunctionsRemote Measurement FunctionsThis section contains the following topics:l "Measurement Grou
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveSave As . . .When you press “Save As”, the analyzer brings up a Windows dialog and a m
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveFor all of the Limit Data Files:My Documents\<mode name>\data\limitsFor all of t
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveKey PathSave, DataMode AllNotes The key location is mode-dependent and will vary.Bring
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveScreen ImagePressing Screen Image accesses a menu of functions that enable you to spec
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveFor versions previous to A.01.55, if you initiate a screen image save by navigating th
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSave3D ColorSelects a standard color theme with each object filled, shaded and colored as
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveSave As…When you press “Save As”, the analyzer brings up a Windows dialog and a menu e
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveThe default path for Screen Images isMy Documents\<mode name>\screen.where <m
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveKey PathSave, Screen ImageNotes Brings up Save As dialog for saving a Screen Image Sav
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveSave As…When you press “Save As”, the analyzer brings up a Windows dialog and a menu e
3 Programming the AnalyzerRemote Measurement FunctionsMEASure Command:MEASure:<measurement>[n]?This is a fast single-command way to make a meas
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveNotes The string must be a valid logical path.Changes the default directory for a mass
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveRemote Command:MMEMory:DATA <file_name>, <data>:MMEMory:DATA? <file_nam
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSaveMass Storage Remove Directory (Remote Command Only)Remote Command:MMEMory:RDIRectory &
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSingle (Single Measurement/Sweep)Single (Single Measurement/Sweep)Sets the analyzer for Si
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSourceSourceThere is no Source control functionality for this measurement. When this key i
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSourceAmplitudeAllows you to access the Amplitude sub-menu to control various amplitude pa
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSourceThis alias is for the ESA tracking generator. It specifies the source output power
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSourceKey PathSource, AmplitudeMode SAScope Mode GlobalRemote Command:SOURce:POWer:SWEep &
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSourcel SOURce:POWer:MODE SWEep is equivalent to :SOURce:POWer:SWEep:STATeONPreset This is
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSourceAmptd Step Auto/ManAllows you to set the step size associated with the Source > A
3 Programming the AnalyzerRemote Measurement FunctionsMeasurement settings persist if you initiate a different measurement and then return to aprevio
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSourceSource Frequency = (Analyzer Frequency *Multiplier Numerator / Multiplier Denominato
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSourceMultiplier DenominatorThe multiplier denominator parameter offsets the source freque
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSourcesweeping in the opposite direction from the analyzer, and it will not be possible tr
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSourceMode SAScope Mode GlobalRemote Command:SOURce:FREQuency:OFFSet <freq>:SOURce:F
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSourceAs stated above, when the Source Mode is set to Tracking, the analyzer acquires cont
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSourceWhen you set the Source Mode to OFF, it releases the Source (and puts it into Local)
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSourceAgilent EXG N5172B X X X X XAgilent MXG N5182B X X X X XAgilent PSG E8257D X X XAgil
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSourceFor X-Series software versions earlier than A.10.01, hardware triggering was unavail
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSourceFor example, if no Source has yet been selected, the statement at the bottom of the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSource[None] on a Restore Input/Output Defaults.If an internal Tracking Generator is insta
3 Programming the AnalyzerRemote Measurement FunctionsSee each command for details of what types of scalar results or trace data results are availabl
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSourcel Amplitude Step = Autol Power Sweep = 0 dBl Amplitude Offset = 0 dBl Source Sweep R
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSourceSource Setting Query (Remote Command Only)This query can be used to get certain sett
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSPAN X ScaleSPAN X ScaleActivates the Span function and displays a menu of span functions.
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSPAN X ScaleIf Source Mode is set to Tracking, and the Span is therefore limited by the li
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSPAN X ScaleSpan PresetsThe following table provides the Span Presets for the Spectrum Ana
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSPAN X ScaleNote that if you are in External Mixing, the maximum Span will be equal to the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSPAN X ScaleThe center frequency for the lower window is limited by the start and stop fre
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSPAN X ScaleThe span is dependent on the currently selected Input (see the Section “Input/
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSPAN X ScaleZero Span Swept SpansX axis is time X axis is frequencyThere is no auto-RBW se
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSPAN X ScaleIf this key is pressed while in a nonzero span, and the previous value of span
3 Programming the AnalyzerRemote Measurement Functionschanges from Channel Power back to ACP and, using the previous ACP settings, themeasurement is
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSPAN X ScaleSignal Track can only function properly if the trace Marker 1 is on is updatin
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSPAN X ScaleIf the signal is lost, an attempt will be made to find it again and continue t
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlSweep/ControlAccesses a menu that enables you to configure the Sweep and Cont
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlTime takes into account both the data acquisition time and the processing tim
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlZero Span, the Auto/Man state of Sweep Time that existed before entering Zero
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlSwept Sweep Type (either manually or automatically chosen) and not when in FF
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlSetting Sweep Time Rules to SA-Accuracy will result in slower sweep times tha
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlReadback SA - NormalInitial S/W Revision Prior to A.02.00SA - AccuracyChooses
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/Controlnarrowband filters. The number of measurement points can also be reduced to s
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlPreset AUTOBackwardsCompatibility SCPI[:SENSe]:SWEep:TYPE AUTOsets sweep type
3 Programming the AnalyzerRemote Measurement Functionsl Returns a 0 if the measured results pass when compared with the current limits.l Returns a 1
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlState Saved Saved in instrument stateReadback SweptInitial S/W Revision Prior
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlPreset DRANgeState Saved Saved in instrument stateBackwards CompatibilityNote
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlExample SWE:TYPE:AUTO:RUL DRAN sets the auto rules to dynamic range.Couplings
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlRemote Command[:SENSe]:SWEep:FFT:WIDTh <real>[:SENSe]:SWEep:FFT:WIDTh?E
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlKey PathSweep/Control, Sweep SetupRemote Command[:SENSe]:SWEep:FFT:WIDTh:AUTO
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlFurther improvement in dynamic range is possible by changing the FFT IF Gain
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlNote that the FFT Width setting will have no effect unless in an FFT sweep.Se
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/Controlstill less than the intended segment width. The “Span” used in this computati
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/Control–8 dBm at the input mixer). But FFT processing experiences overloads at the m
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/Controlincluding the Span you have set. Usually the instrument picks the optimal FF
3 Programming the AnalyzerRemote Measurement Functionsthe first burst in each frame. The command can also be used to identify the best curve fit for
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlOption B40, 40 MHz.BackwardsCompatibility SCPI[:SENSe]:SWEep:FFT:SPAN:RATio &
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlAlthough narrowing the segment width can allow higher dynamic ranges some cas
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlFFT WidthThis menudisplays and controls the width of the FFT’s performed whil
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlState Saved Saved in instrument stateMin 4.01 kHzMax The maximum available FF
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlHowever, in order to increase dynamic range, most X-series models provide a s
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlThe 10 MHz path is always used for Swept sweeps. It is always used for FFT sw
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlKey PathSweep/Control, Sweep SetupRemote Command[:SENSe]:SWEep:FFT:WIDTh <
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlInitial S/W Revision Prior to A.02.00Modified at S/WRevisionA.04.00Key PathSw
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/Controldrive level. If you reduce the width of an FFT, an analog filter is placed be
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/Controlthe current setup; but on occasion you may wish to limit the FFT Width to be
3 Programming the AnalyzerRemote Measurement FunctionsOption DescriptionMEAN("Note 1" onpage 120)Returns a single value that is the arithme
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlBackwardsCompatibility SCPI[:SENSe]:SWEep:FFT:SPAN:RATio <integer>[:SEN
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlAlthough narrowing the segment width can allow higher dynamic ranges some cas
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlFFT WidthThis menudisplays and controls the width of the FFT’s performed whil
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlState Saved Saved in instrument stateMin 4.01 kHzMax The maximum available FF
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlHowever, in order to increase dynamic range, most X-series models provide a s
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlThe 10 MHz path is always used for Swept sweeps. It is always used for FFT sw
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlKey PathSweep/Control, Sweep SetupRemote Command[:SENSe]:SWEep:FFT:WIDTh <
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlInitial S/W Revision Prior to A.02.00Modified at S/WRevisionA.04.00Key PathSw
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/Controldrive level. If you reduce the width of an FFT, an analog filter is placed be
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/Controlthe current setup; but on occasion you may wish to limit the FFT Width to be
3 Programming the AnalyzerRemote Measurement FunctionsOption DescriptionEquation 4: RMS Value of Data Points for Specified Region(s)where Xi is a dat
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlBackwardsCompatibility SCPI[:SENSe]:SWEep:FFT:SPAN:RATio <integer>[:SEN
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlAlthough narrowing the segment width can allow higher dynamic ranges some cas
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlFFT WidthThis menudisplays and controls the width of the FFT’s performed whil
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlState Saved Saved in instrument stateMin 4.01 kHzMax The maximum available FF
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlHowever, in order to increase dynamic range, most X-series models provide a s
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlThe 10 MHz path is always used for Swept sweeps. It is always used for FFT sw
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlWhen the Gate Function is on, the selected Gate Method is used along with the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/Controll When Gate is on, Offset Res BW and Offset Video BW are ignored (if you set
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/Control• When Gate View is turned on, the instrument is set to Zero Span.• Gate View
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlA sample of the Gate View screen in other measurements is shown in the follow
Table Of ContentsDET (Detection Mode) 273Syntax 273Legacy Products 273Description 273DL (Display Line) 274Syntax 274Legacy Products 274Description 275
3 Programming the AnalyzerRemote Measurement FunctionsOption Descriptionwhere |Xi| is the magnitude of an I/Q pair, X is the mean of the magnitudes f
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/Controlchanges, even if the window is not being updated. In Gated LO and Gated Video
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/Control[:SENSe]:SWEep:EGATe:TIME?Example SWE:EGAT:TIME 500 msDependencies Gate View
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlGate DelayControls the length of time from the time the gate condition goes T
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlThe key is also grayed out if Gate Control = Level.Preset 461.6 usWiMAX OFDMA
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlWhen in zero span, there is no actual sweep performed. But data is only taken
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlGated FFT cannot be done in zero span since the instrument is not sweeping. S
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlLinePressing this key, when it is not selected, selects the line signal as th
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlExternal 1Pressing this key, when it is not selected, selects an external inp
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlBackwardsCompatibility SCPI:TRIGger[:SEQuence]:EXTernal:LEVelFor backward com
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlTRIG:<meas>:SOUR EXT2 Measurements other than Swept SADependencies I
3 Programming the AnalyzerRemote Measurement FunctionsNon-Constant EnvelopeSee table below for explanation of variables.Variable Description<soffs
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlTrig SlopeControls the trigger polarity. It is set positive to trigger on a r
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/Controlmessage ("Waiting for trigger") is generated if no trigger signal a
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlMin –200 dBmMax 100 dBmDefault Unit depends on the current selected Y-Axis un
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/Control3. If the new absolute RF Burst level differs from the previous by more than
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlRemote Command:TRIGger[:SEQuence]:RFBurst:SLOPe POSitive|NEGative:TRIGger[:SE
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlThis feature selects the internal periodic timer signal as the trigger. Trigg
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlPeriodSets the period of the internal periodic timer clock. For digital commu
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlOffsetAdjusts the accumulated offset between the periodic timer events and th
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlPreset 0 sState Saved Saved in instrument stateMin –10.000 sMax 10.000 sDefau
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlPreset OffGSM/EDGE: RFBurstState Saved Saved in instrument stateReadback The
3 Programming the AnalyzerRemote Measurement FunctionsVariable DescriptionIts unit is seconds for time-domain traces, or a dimensionless index (0 to
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlThe Status Operation Register bit 5 "Waiting for Trigger" is set at
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/Control:TRIGger[:SEQuence]:EXTernal1:SLOPe?Example TRIG:EXT1:SLOP NEGCouplings This
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlInitial S/W Revision Prior to A.02.00Modified at S/WRevisionA.03.00Trigger Le
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlPreset POSitiveState Saved Saved in instrument stateBackwardsCompatibility SC
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlAbsolute Trigger LevelSets the absolute trigger level for the RF burst envelo
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/Control:TRIGger[:SEQuence]:RFBurst:LEVel:TYPE?Example TRIG:RFB:LEV:TYPE RELsets the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/Controlneed to send the :TRIGger[:SEQuence]:RFBurst:LEVel:TYPE command, above.The re
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlTVPressing this key, when it is not selected, selects the TV input signal as
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlSCPI command is sent while the key is blanked, an error is returned.Readback
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlKey PathTrigger, TVRemote Command:TRIGger[:SEQuence]:TV:FMODe ENTire|ODD|EVEN
3 Programming the AnalyzerRemote Measurement Functions:CALCulate:DATA[1]|2|...6:PEAKs? <threshold>,<excursion>[,AMPLitude |FREQuency | TI
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlMaximum line is 313 for formats PAL-B, D, G, H, I, PAL-N, PAL-N Combin, and S
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlPreset MNTSState Saved Saved in instrument stateReadback Displays Readback va
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlKey PathTrigger, TV, StandardExample TRIG:TV:STAN MPALReadback PAL-MInitial S
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlKey PathTrigger, TV, StandardExample TRIG:TV:STAN PAL60Readback PAL-NInitial
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlGate HoldoffLets you increase or decrease the wait time after a gate event en
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlExample SWE:EGAT:HOLD 0.0002SWE:EGAT:HOLD?SWE:EGAT:HOLD:AUTO ONSWE:EGAT:HOLD:
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlThis command sets gate parameter values to the ESA preset values, as follows:
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlSWE:EGAT:POL?Preset POSitiveState Saved Saved in instrument stateBackwardsCom
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlKey PathSweep/ControlRemote Command[:SENSe]:SWEep:POINts <integer>[:SEN
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlBackwards CompatibilityNotes1. In ESA and PSA, Sweep Points was adjustable wi
3 Programming the AnalyzerRemote Measurement Functionsl TIME - lists the peaks in order of occurrence, left to right across the x-axis.lPeaks vs. Dis
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlWhen Paused, the label on the key changes to Resume. Pressing Resume un-pause
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSweep/ControlStatus Bits/OPCdependenciesThe STATus:OPERation register bits 0 through 8 are
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemSystemOpens a menu of keys that access various configuration menus and dialogs.Key P
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemrelation to the size of the SCPI queue. If the queue extends onto a second page, a s
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemnumbers in the X-Series and those of earlier products. Error, event, and status proc
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemHistoryThe History and Status keys select the Errors view. The Status key has a seco
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemState Saved NoRange On | OffInitial S/W Revision Prior to A.02.00RefreshWhen pressed
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystem:SYSTem:ERRor:OVERload OFF command. In either case, Input Overloads always set the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemKey PathSystem, ShowMode AllExample SYST:SHOW SYSTBackwards CompatibilityNotesThe ha
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemNotes dedicated Show Hardware Statistics screen in the Service Menu.Initial S/W Revi
3 Programming the AnalyzerRemote Measurement Functionsan error. Sending ASCII data when a definite block is expected generates message –161 "Inv
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemShow System contents (Remote Command Only)A remote command is available to obtain th
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemThe Previous Page is grayed-out if the first page of information is presently displa
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemMode and Input/Output DefaultsWhen the analyzer is powered on in Mode and Input/Outp
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemhappens behind the scenes when a controlled shutdown is requested by using the front
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemTDSCDMA | VSA | VSA89601 | WCDMA | WIMAXOFDMA:SYSTem:PON:MODE?Example SYST:PON:MODE
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemPreloading enables you to “preload” at startup, to eliminate the runtime delay. Pr
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemYELLOW: the applications you have selected can all fit into the analyzer’s memory,
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemKey PathSystem, Power On, Configure ApplicationsInitial S/W Revision A.02.00Select/D
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemInitial S/W Revision A.02.00Modified at S/WRevisionA.04.00Exit Without SavingPressin
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemConfigure Applications - Remote CommandsThe following topics provide details on usin
3 Programming the AnalyzerRemote Measurement Functionsl NORMal order begins with the most significant byte (MSB) first, and ends with the leastsignif
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemConfiguration Memory Total (Remote Command Only)Queries the limit of Virtual Memory
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemKey PathSystemInitial S/W Revision Prior to A.02.00Auto AlignConfigures the method f
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemNormalAuto Align, Normal turns on the automatic alignment of all measurement systems
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemThe Auto Align, Alert mechanism will notify you when alignments have expired. One so
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemWhen Auto Align, Off is selected the Settings Panel indicates ALIGN OFF with a warni
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemAlertThe instrument will signal an Alert when conditions exist such that you will ne
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystem24 hoursWith Auto Align Alert set to 24 Hours the instrument will signal an alert af
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemNo confirmation is required when Alert is configured through a remote command.Key Pa
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemNo confirmation is required when Alert is configured through a remote command.Key Pa
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemKey PathSystem, AlignmentsInitial S/W Revision Prior to A.02.00AllImmediately execut
3 Programming the AnalyzerSTATus SubsystemSTATus SubsystemThe following diagram shows the entire Status Register Subsystem implementation of the XSe
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemattenuator and Electronic attenuator alignments on the RF Preselector path. The pu
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemSee additional remarks described with :CALibration[:ALL]?Everything about :CALibrati
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystem:CALibration:NRF? returns 1 if failedWhile Align Now, All but RF is performing the a
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemKey PathSystem, Alignments, Align NowMode AllRemote Command:CALibration:RF:CALibrati
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemKey PathSystem, Alignments, Align NowMode AllRemote Command:CALibration:EMIXer:CALib
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemA successful Align Now, RF will set the Last Align RF temperature to the current tem
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemKey PathVisual annotation in the Show Alignment Statistics screenMode AllRemote Comm
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemExample :CAL:TIME:LRF?Notes Value is the elapsed time, in seconds, since the last su
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemKey PathVisual annotation in the Show Alignment Statistics screenMode AllRemote Comm
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemKey PathVisual annotation in the Show Alignment Statistics screenMode AllRemote Comm
3 Programming the AnalyzerSTATus SubsystemWhat Are Status RegistersThe status system contains multiple registers that are arranged in a hierarchical
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemKey PathVisual annotation in the Show Alignment Statistics screenMode AllRemote Comm
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemParameter SettingTimebase DAC CalibratedTimebase DAC setting Calibrated valueAuto Al
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemKey PathSystem, AlignmentsMode AllRemote Command:CALibration:DATA:DEFaultExample :CA
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemThe backup screen indicates the approximate amount of space required to contain the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemChanging the drive letter also modifies the path displayed in the dialog below. When
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemRemote Language Compatibility Measurement Application Reference 1285
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemThe restore operation checks the validity of the restore file using the database&apo
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemChanging the drive letter also modifies the path displayed in the box below. When th
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystem1288 Remote Language Compatibility Measurement Application Reference
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemPerform Backup (Remote Command Only)Invokes an alignment data backup operation to th
3 Programming the AnalyzerSTATus SubsystemWhat Are Status Register SCPI CommandsMost monitoring of the instrument conditions is done at the highest l
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemRemote Command:CALibration:DATA:RESTore <filename>Example :CAL:DATA:REST "
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemThe last Characterize Preselector Time and Temperature survives across the power cyc
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemIf the value of the Timebase DAC changes (by switching to Calibrated from User with
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemMode AllExample :CAL:FREQ:REF:MODE USERReadback Text xxx < where xxx is the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemI/O ConfigActivates a menu for identifying and changing the I/O configuration for re
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemenabled, the instrument can run software applications that use the instrument's
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemExample :SYST:COMM:GPIB:CONT ON Will set GPIB port to ControllerInitial S/W
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemRemote Command:SYSTem:COMMunicate:LAN:SCPI:SOCKet:ENABle OFF|ON|0|1:SYSTem:COMMunica
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemState Saved NoRange On | OffInitial S/W Revision Prior to A.02.00HiSLIP ServerTurns
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemMode AllRemote Command:SYSTem:COMMunicate:LAN:SCPI:SOCKet:CONTrol?Example :SYST:COMM
Table Of ContentsSyntax 283Legacy Products 283Description 283EDITDONE (Edit Done) 284Syntax 284Legacy Products 284Description 284EDITLIML (Edit Limit
3 Programming the AnalyzerSTATus Subsystem• you are monitoring more than one device which supports SRQs• you need to have the controller do something
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemLXIOpens a menu that allows you to access the various LXI configuration properties.K
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemFactoryThis key selects the factory setting, for example:“Agilent Technologies,N9020
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemThis is reserved for future use. The T+M488 protocol is not supported on low speedco
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemRemote Command:SYSTem:COMMunicate:USB:PACKets?Example :SYST:COMM:USB:PACK?Notes Two
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemKey PathSystem, Restore System DefaultsExample :SYST:DEF INPInitial S/W Revision Pri
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemRestore Align DefaultsThis selection causes the Alignment system settings to be a re
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemMiscellaneous Setting Default ValueGPIB Address 18Auto File Name Number 000Save Type
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemRestore Mode Defaults (All Modes)This selection resets all of the modes in the instr
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemKey PathSystem, Restore System DefaultsExample :SYST:DEF ALLCouplings An All will ca
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemOr use Alt-Tab: press and hold the Alt key and press and release the Tab key until
3 Programming the AnalyzerSTATus SubsystemUsing a Status RegisterEach bit in a register is represented by a numerical value based on its location. Se
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemKey PathSystemNotes No equivalent remote command for this key.Backwards Compatibilit
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemRemote Command:SYSTem:LKEY:LIST?NotesReturn Value:An <arbitrary block data> of
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemNotes Return value is the host ID as a stringInitial S/W Revision Prior to A.02.00Se
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemRead-WriteSelection for allowing full read-write access to the USB ports.Key PathSys
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemThe CXA models in which the AC/DC Switch field is called Fixed Atten and which omit
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSysteml "Query the Mechanical Relay Cycle Count" on page 1315l "Query the O
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemMode AllRemote Command:SYSTem:TEMPerature:HEXTreme?Example :SYST:TEMP:HEXT?Notes Val
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemKey PathSystemModeAllNotes No equivalent remote command for this key.Initial S/W Rev
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemRemote Command:SYSTem:OPTions?Example :SYST:OPT?Notes The return string is a comma s
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemRemote Command:SYSTem:HELP:HEADers?Example :SYST:HELP:HEAD?Notes The output is an IE
3 Programming the AnalyzerSTATus Subsystem4. So now the only output from the Status Questionable Integrity register will come from a bit 10positive t
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSystemTime (Remote Command Only)Sets or queries the time in the instrument.Mode AllRemote
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorTrace/DetectorThe Trace/Detector menu lets you control the acquisition, disp
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorState Saved The type of each trace is saved in instrument stateInitial S/W R
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorState Saved The state of Average is saved in Instrument State for ghosting p
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/Detector2. The trace is updated in a series of discrete steps, with measurement data
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/Detectordetector for each trace, but the analyzer hardware provides the maximum flex
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorLDIF =Log DifferenceSelect TraceDetermines which trace the type control k
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorSelect TraceDetermines which trace the type control keys will affect. When y
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorSelect TraceDetermines which trace the type control keys will affect. When y
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorBackwards CompatibilityNotesPrevious to the X-Series, pressing Clear Write w
3 Programming the AnalyzerSTATus Subsystem• The instrument does not have a service request pending. (A service request is considered to bepending bet
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/Detector• The average/hold count k is set to 1, so that the next time the average tr
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorWhenever you press Max Hold or send the equivalent SCPI command, Update is s
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorRemember that restarting Min Hold also restarts Max Hold and averaging, as t
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorView/BlankThis key lets you set the state of the two trace variables, Update
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/Detectorthe trace in Trace On (Update On and Display On), even if that detector was
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorBackwardsCompatibility SCPI:TRACe:MODE BLANksets :TRACe:UPDate OFF, :TRACe:D
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/Detector• View: Update Off and Display On• Blank: Update Off and Display Off• Backgr
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorTrace Update State On/OffKey PathTrace/DetectorRemote Command:TRACe[1]|2|...
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorMore InformationWhen a trace becomes inactive, the following things happen:•
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/Detectortype letter in the trace annotation panel in the Measurement bar. So in the
3 Programming the AnalyzerSTATus SubsystemThe Status Byte RegisterThe RQS bit is read and reset by a serial poll. The same bit position (MSS) is read
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/Detector:TRACe[1]|2|...6:UPDate[:STATe]?Example TRAC2:UPD 0 Makes trace 2 inactive (
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorInactive traces display across the entire X Axis of the instrument. Their ho
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorSee "Trace Update State On/Off" on page 1342.See "Trace Displ
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/Detectorand Blank were trace modes, set by TRACe:MODE command. In the X-Series, Vie
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/Detector• if the trace is the target of a Copy or participant in an Exchange• if the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/Detectorpossible combinations:• Trace On: Update and Display both On• View: Update O
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorTrace Display State On/OffKey PathTrace/DetectorRemote Command:TRACe[1]|2|..
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorTraces which are blanked (Display=off) do not display nor appear on printout
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorPOS =Positive peakSAMP =SampleNEG
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/Detector[:SENSe]:DETector[:FUNCtion]?Example DET AVER Sets detector to average for a
3 Programming the AnalyzerSTATus SubsystemBit Description0, 1 These bits are always set to 0.2 A 1 in this bit position indicates that the SCPI error
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/Detectorfrom the selected CISPR detector to an auto coupled detector according to th
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorWhen the Detector choice is Auto, the detector selected depends on marker fu
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorRemote Command[:SENSe]:DETector:AUTO ON | OFF | 1 | 0[:SENSe]:DETector:AUTO?
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/Detector• Log power (also known as video)• Power (also known as RMS)• Voltage envelo
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorPeak detection is used for CW measurements and some pulsed-RF measurements.
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorNegative PeakFor each bucket (interval) in the trace, Negative Peak detectio
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/Detectortraces for which this detector is selected (other than to slow down the swee
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorNote that CISPR standard operation is to perform the envelope averaging on t
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorExample DET:TRAC3 RAV Selects the RMS Average detector for trace 3.Notes Thi
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorAll Traces AutoThis is designed to quickly return the selected set of detect
3 Programming the AnalyzerSTATus SubsystemIn addition to the status byte register, the status byte group also contains the service requestenable regi
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorKey PathTrace/DetectorRemote Command:TRACe:CLEar TRACE1|TRACE2|TRACE3|TRACE4
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/Detectorfunction, the indicated function is performed during the sweep with the math
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorCouplings Whenever a math function is turned on for a trace, that trace is s
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorRemote Language Compatibility Measurement Application Reference 1363
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorFor each active trace, the current trace point is processed for Trace 1, the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorSelect TraceDetermines which trace the type control keys will affect. When y
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorSelect TraceDetermines which trace the type control keys will affect. When y
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorKey PathTrace/Detector, MathExample :CALC:MATH TRACE1,PDIF,TRACE4,TRACE5,,Se
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorDuring the sweep, the following formula is executed for each point in the tr
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorThe values of the operand trace points are assumed to be in decibel units (a
3 Programming the AnalyzerSTATus SubsystemStandard Event Status RegisterThe standard event status register contains the following bits:Remote Languag
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorNotes See Trace “Math”.State Saved The current trace math function is saved
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorKey PathTrace/Detector, Math, Trace OperandsDependencies The First Trace can
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorOperand 1Selects the first trace operand to be used for the trace math funct
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorOperand 2Selects the second trace operand to be used for the trace math func
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorReadback Trace <trace number>Initial S/W Revision Prior to A.02.00Oper
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorPreset Trace number – 1 (wraps at 1). For example, for Trace 1, the Second T
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorDependencies When Signal ID is on, this key is grayed out.PresetTRACE1, TRA
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorFrom TraceSelects the trace to be copied to or exchanged with the To TraceKe
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorFrom TraceSelects the trace to be copied to or exchanged with the To TraceKe
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorTo TraceSelects the trace to be copied from or exchanged with the From Trace
3 Programming the AnalyzerSTATus SubsystemBit Description0 A 1 in this bit position indicates that all pending operations were completedfollowing exe
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorTo TraceSelects the trace to be copied from or exchanged with the From Trace
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorNormalize On/OffNormalize (On) activates the normalize function. On each swe
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/Detector(as before). When Normalize is turned on, the result is the calibrated retu
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/Detectortrace query results. In other words, both trace query result and marker Y be
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorExample TRAC3:DISP 1 Shows the reference trace.Notes Use the TRAC3:DISP comm
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorOpen/Short Guided CalOn pressing the Open/Short Cal softkey in the Normalize
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorKey PathTrace/Detector, NormalizeRemote Command:DISPlay:WINDow[1]:TRACe:Y[:S
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorSend/Query Trace Data (Remote Command Only)This command allows trace data to
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorMore InformationThe format and byte-ordering of the sent or received data de
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorSmoothes the trace according to the number of points specified in :TRACe:MAT
3 Programming the AnalyzerSTATus Subsystemnumber 7 and bit number 3 are enabled, the decimal sum of the 2 bits is 128 plus 8. So thedecimal value 136
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorRefer to the figure above for a discussion of this end-point smoothing pheno
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrace/DetectorMean Trace Data (Remote Command Only)Included for ESA compatibility. Not rec
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerTriggerAccesses a menu of keys to control the selection of the trigger source and t
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerOther trigger-related commands are found in the INITiate and ABORt SCPI commandsubs
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerMeas Mode Preset for RF Preset for IQ NotesSwept SA SA IMM IQ notsupportedCHP SA, W
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerCMMB, ISDB-T,Digital Cable TV,MSRTx Power SA, GSM, TD-SCDMASA, GSM:RFBurstTD-SCDMA:
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerRFBurstAll others:IMMediateGSM/EDGE:IQMagAll others:IMMMediatePVT WIMAXOFDMA RFB IM
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerPowerLE In-bandEmissionsBLUETOOTH IMM IQ notsupportedEDR In-bandSpuriousEmissionsBL
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerfront panel. In some models, there is no second External input. In these models,
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrigger−IINPut - triggers on the I channel's ADC voltage−QINPut - triggers on the Q c
Table Of ContentsLegacy Products 296Description 296FPKA (Fast Preselector Peak) 298Syntax 298Legacy Products 298Description 298FREF (Frequency Referen
3 Programming the AnalyzerSTATus SubsystemThe bit is valid for most X-Series Modes.5 Waiting for trigger The instrument is waiting for the trigger co
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerThe following examples show trigger setup parameters using an external trigger sour
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerevent occurs and all the applicable trigger criteria have been met). A correspondin
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerTrigger LevelSets a level for the video signal trigger. When the video signal cross
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerTrig SlopeControls the trigger polarity. It is set positive to trigger on a rising
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerRemote Command:TRIGger[:SEQuence]:VIDeo:DELay <time>:TRIGger[:SEQuence]:VIDeo
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerRemote Command:TRIGger[:SEQuence]:OFFSet <time>:TRIGger[:SEQuence]:OFFSet?:TR
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerTrig SlopeControls the trigger polarity. It is set positive to trigger on a rising
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerDefault Unit SBackwards CompatibilityNotesThe legacy :TRIGger[:SEQuence]:DELay comm
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerExample TRIG:EXT1:LEV 0.4 VCouplings This same level is used for the Ext1 trigger s
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerTrig DelayControls a time delay during which the analyzer will wait to begin a swee
3 Programming the AnalyzerSTATus Subsystem"Operation Event Query" on page 142"Operation Negative Transition" on page 142"Ope
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerKey PathTriggerExample TRIG:SOUR EXT2 Swept SA measurementTRIG:<
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerCompatibility SCPIInitial S/W Revision Prior to A.02.00Trig SlopeControls the trigg
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerNotes Video trigger delay may be set to negative values, in time domain, FFT and ev
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerBackwards CompatibilityNotesThe legacy command::TRIGger[:SEQuence]:RFBurst:FSELecti
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerDefault Unit depends on the current selected Y-Axis unitBackwardsCompatibility SCPI
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrigger3. If the new absolute RF Burst level differs from the previous by more than 0.5 dB
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerRemote Command:TRIGger[:SEQuence]:RFBurst:SLOPe POSitive|NEGative:TRIGger[:SEQuence
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerBackwards CompatibilityNotesThe legacy :TRIGger[:SEQuence]:DELay command affects th
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerfrequencies. For example, we might want to measure spurious transmissions at an off
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerto OFF, and the external sync source rate is changed for some reason, the periodic
3 Programming the AnalyzerSTATus SubsystemdependenciesInitial S/W Revision Prior to A.02.00Operation Event QueryThis query returns the decimal value
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerRemote Command:TRIGger[:SEQuence]:FRAMe:OFFSet <time>:TRIGger[:SEQuence]:FRAM
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerRemote Command:TRIGger[:SEQuence]:FRAMe:ADJust <time>Example TRIG:FRAM:ADJ 1.
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerSync SourceSelects a signal source for you to synchronize your periodic timer trigg
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerExternal 1Pressing this key, when it is not selected, selects the external input po
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerTrig SlopeControls the trigger polarity. It is set positive to trigger on a rising
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerTrigger LevelSets the value where the external 2 trigger input will trigger a new s
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerRF BurstPressing this key, when it is not selected, selects the RF Burst as the tri
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerScope Meas GlobalRemote Command:TRIGger[:SEQuence]:RFBurst:LEVel:ABSolute <ampl&
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerModified at S/WRevisionA.04.00Relative Trigger LevelSets the relative trigger level
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerGSM: –25 dBState Saved Saved in instrument stateMin –45 dBMax 0 dBDefault Unit dB
3 Programming the AnalyzerSTATus SubsystemOperation Positive TransitionThis command determines which bits in the Operation Condition register will se
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerKey PathTrigger, Periodic TimerRemote Command:TRIGger[:SEQuence]:FRAMe:DELay <ti
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerField Two, lines 314 to 625As the Field is changed, the appropriate value for Line
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerwithin the TV trigger setup functions.Preset 17State Saved Saved in instrument stat
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerField OneWhen you select Field One it causes the selected line number to be viewed
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerAs the TV standard is changed, the current line value is clipped as necessary to ke
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerNTSC–4.43Sets the TV standard to NTSC–4.43.Key PathTrigger, TV, StandardExample TRI
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerPAL-B,D,G,H,ISets the TV standard to PAL-B,D,G,H,IKey PathTrigger, TV, StandardExam
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTrigger• If Holdoff On and Type = Normal, readback value• If Holdoff On and Type = Above,
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceTriggerKey PathTrigger, Auto/HoldoffRemote Command:TRIGger[:SEQuence]:HOLDoff <time>
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceUser PresetUser PresetAccesses a menu that gives you the following three choices:• User Pr
3 Programming the AnalyzerSTATus Subsystem"Questionable Negative Transition " on page 145"Questionable Positive Transition" on pa
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceUser PresetThe User Preset function does the following:• Aborts the currently running meas
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceUser Preset• Clears the input and output buffers.• Sets the Status Byte to 0.Key PathUser
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceView/DisplayView/DisplayThe View/Display key opens the Display Menu (common to most measur
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceView/DisplayExample :DISP:VIEW ZSP sets the zone span viewDependencies All views except
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceView/DisplaySee the figure below. Each type of annotation can be turned on and off individ
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceView/DisplayKey PathView/Display, Display, AnnotationRemote Command:DISPlay:ANNotation:MBA
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceView/DisplayKey PathView/Display, Display, AnnotationRemote Command:DISPlay:ANNotation:TRA
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceView/DisplayKey PathView/Display, Display, AnnotationRemote Command:DISPlay:ACTivefunc[:ST
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceView/DisplayExample DISP:ANN:TITL:DATA "This Is My Title"This example is for the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceView/DisplayKey PathView/Display, DisplayRemote Command:DISPlay:WINDow[1]:TRACe:GRATicule:
3 Programming the AnalyzerSTATus SubsystemdependenciesInitial S/W Revision Prior to A.02.00Questionable Event QueryThis query returns the decimal val
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceView/DisplayMin –∞ (minus infinity) in current unitsMax +∞ (plus infinity) in current unit
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceView/DisplayAnnotation Local SettingsThis is a Mode Global override of the meas local anno
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceView/DisplayThemeThis key allows you to change the Display theme. This is similar to the T
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceView/DisplayFlat ColorSelects a format that is best when the screen is to be printed on an
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceView/DisplayKey PathView/Display, Display, System Display Settings, BacklightExample DISP:
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceView/Display• If, while in External Mixing, the Mixer Preset changes (for example, if you
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceView/Displayput into Display Trace 1, and all the other traces “roll up.” Once the trace d
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceView/DisplayNote that since the spectrogram is intended to give a view of spectral behavio
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceView/DisplayRepresentation of TimeIn the Spectrogram view, zero time is the point where th
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceView/Displayinaccuracies within each trace are therefore reconciled with the start of the
3 Programming the AnalyzerSTATus SubsystemQuestionable Positive TransitionThis command determines which bits in the Questionable Condition register w
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceView/DisplayThe zoom region is indicated by a blue shading over the whole region. In the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceView/DisplayTransition RulesWhen you enter the Trace Zoom view, the top window of Trace Zo
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceView/DisplayMore InformationIn Zone Span, the window with the focus (the selected window)
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceView/DisplayMeasurement Swept SARemote Command:TRACe:DISPlay:VIEW:SPECtrogram:POSition <
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceView/DisplayBackwards CompatibilityNotesIn ESA/PSA, Full Screen was turned on with a softk
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceView/DisplayNotesInitial S/W Revision Prior to A.02.00Remote Language Compatibility Measur
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceView/Display1466 Remote Language Compatibility Measurement Application Reference
3 Programming the AnalyzerSTATus SubsystemMode AllRemote Command:STATus:QUEStionable:CALibration:CONDition?Example STAT:QUES:CAL:COND?Preset 0Status
3 Programming the AnalyzerSTATus SubsystemExample STAT:QUES:CAL?Preset 0Status Bits/OPC dependencies Sequential commandInitial S/W Revision Prior to
3 Programming the AnalyzerSTATus SubsystemPreset 32767Min 0Max 32767Status Bits/OPC dependencies Sequential commandInitial S/W Revision Prior to A.02
Table Of ContentsDescription 308HD (Hold Data Entry) 309Syntax 309Legacy Products 309Description 309I1 [one] (Set RF Coupling to DC) 310Syntax 310Lega
3 Programming the AnalyzerSTATus SubsystemMode AllRemote Command:STATus:QUEStionable:CALibration:SKIPped:ENABle <integer>:STATus:QUEStionable:C
3 Programming the AnalyzerSTATus Subsystem:STATus:QUEStionable:CALibration:SKIPped:NTRansition?Example STAT:QUES:CAL:SKIP:NTR 1Align RF skipped is no
3 Programming the AnalyzerSTATus Subsystem"Questionable Calibration Extended Failure Positive Transition" on page 154Questionable Calibrati
3 Programming the AnalyzerSTATus SubsystemQuestionable Calibration Extended Failure Event QueryThis query returns the decimal value of the sum of the
3 Programming the AnalyzerSTATus SubsystemQuestionable Calibration Extended Failure Positive TransitionThis command determines which bits in the Ques
3 Programming the AnalyzerSTATus SubsystemRemote Command:STATus:QUEStionable:CALibration:EXTended:NEEDed:CONDition?Example STAT:QUES:CAL:EXT:NEED:CON
3 Programming the AnalyzerSTATus SubsystemPreset 0Status Bits/OPC dependencies Sequential commandInitial S/W Revision Prior to A.02.00Questionable Ca
3 Programming the AnalyzerSTATus SubsystemPreset 32767Min 0Max 32767Status Bits/OPCdependenciesSequential commandInitial S/WRevisionPrior to A.02.00Q
3 Programming the AnalyzerSTATus Subsystem5) in the Questionable Register. The variable <integer> is the sum of the decimal values of the bitsy
3 Programming the AnalyzerSTATus Subsystemhas a negative transition (1 to 0). The variable <integer> is the sum of the decimal values of thebit
Table Of ContentsKSA (Amplitude in dBm) 320Syntax 320Legacy Products 320Description 320KSa (Normal Detection) 321Syntax 321Legacy Products 321Descript
3 Programming the AnalyzerSTATus SubsystemQuestionable Integrity RegisterThe following commands and queries are available for this register:"Que
3 Programming the AnalyzerSTATus SubsystemPreset 32767Min 0Max 32767StatusBits/OPCdependenciesSequential commandInitial S/WRevisionPrior to A.02.00Qu
3 Programming the AnalyzerSTATus SubsystemQuestionable register.Preset 0Min 0Max 32767StatusBits/OPCdependenciesSequential commandInitial S/WRevision
3 Programming the AnalyzerSTATus Subsystem"Questionable Integrity Signal Event Query" on page 164"Questionable Integrity Signal Negati
3 Programming the AnalyzerSTATus SubsystemQuestionable Integrity Signal Event QueryThis query returns the decimal value of the sum of the bits in the
3 Programming the AnalyzerSTATus Subsystemregister bit has a positive transition (0 to 1). The variable <integer> is the sum of the decimalvalu
3 Programming the AnalyzerSTATus SubsystemPreset 0Status Bits/OPC dependencies Sequential commandInitial S/W Revision Prior to A.02.00Questionable In
3 Programming the AnalyzerSTATus SubsystemPreset 0Status Bits/OPC dependencies Sequential commandInitial S/W Revision Prior to A.02.00Questionable In
3 Programming the AnalyzerSTATus Subsystemregister.Preset 32767Min 0Max 32767StatusBits/OPCdependenciesSequential commandInitial S/WRevisionPrior to
3 Programming the AnalyzerSTATus SubsystemQuestionable Power EnableThis command determines which bits in the Questionable Power Condition Register wi
Table Of ContentsSyntax 329Legacy Products 329Description 329KSG (Video Averaging On) 330Syntax 330Legacy Products 330Description 330KSg (Display Off)
3 Programming the AnalyzerSTATus SubsystemQuestionable Power Negative TransitionThis command determines which bits in the Questionable Power Conditio
3 Programming the AnalyzerSTATus SubsystemMax 32767StatusBits/OPCdependenciesSequential commandInitial S/WRevisionPrior to A.02.00Questionable Temper
3 Programming the AnalyzerSTATus SubsystemMode AllRemoteCommand:STATus:QUEStionable:TEMPerature:ENABle <integer>:STATus:QUEStionable:TEMPeratur
3 Programming the AnalyzerSTATus SubsystemMode AllRemoteCommand:STATus:QUEStionable:TEMPerature:NTRansition <integer>:STATus:QUEStionable:TEMPe
3 Programming the AnalyzerSTATus Subsystem174 Remote Language Compatibility Measurement Application Reference
4 List of Legacy Analyzer CommandsThe following table ("Alphanumeric List of all LegacyCommands with N9061A Support" on page 176) lists all
4 List of Legacy Analyzer CommandsAlphanumeric List of all Legacy Commands with N9061A SupportAlphanumeric List of all Legacy Commands with N9061A Su
4 List of Legacy Analyzer CommandsAlphanumeric List of all Legacy Commands with N9061A SupportCommand Description 8566 85688560Series DescriptionACPE
4 List of Legacy Analyzer CommandsAlphanumeric List of all Legacy Commands with N9061A SupportCommand Description 8566 85688560Series DescriptionACTV
4 List of Legacy Analyzer CommandsAlphanumeric List of all Legacy Commands with N9061A SupportCommand Description 8566 85688560Series Descriptionfunc
Table Of ContentsLegacy Products 338Description 338KSl (Transfer Trace B to Trace C) 339Syntax 339Legacy Products 339Description 339KSM (Marker Noise
4 List of Legacy Analyzer CommandsAlphanumeric List of all Legacy Commands with N9061A SupportCommand Description 8566 85688560Series DescriptionCA C
4 List of Legacy Analyzer CommandsAlphanumeric List of all Legacy Commands with N9061A SupportCommand Description 8566 85688560Series Descriptionline
4 List of Legacy Analyzer CommandsAlphanumeric List of all Legacy Commands with N9061A SupportCommand Description 8566 85688560Series DescriptionDA D
4 List of Legacy Analyzer CommandsAlphanumeric List of all Legacy Commands with N9061A SupportCommand Description 8566 85688560Series Descriptionfreq
4 List of Legacy Analyzer CommandsAlphanumeric List of all Legacy Commands with N9061A SupportCommand Description 8566 85688560Series DescriptionFFTC
4 List of Legacy Analyzer CommandsAlphanumeric List of all Legacy Commands with N9061A SupportCommand Description 8566 85688560Series DescriptionGDRV
4 List of Legacy Analyzer CommandsAlphanumeric List of all Legacy Commands with N9061A SupportCommand Description 8566 85688560Series DescriptionHN H
4 List of Legacy Analyzer CommandsAlphanumeric List of all Legacy Commands with N9061A SupportCommand Description 8566 85688560Series DescriptionKS)
4 List of Legacy Analyzer CommandsAlphanumeric List of all Legacy Commands with N9061A SupportCommand Description 8566 85688560Series DescriptionKSC
4 List of Legacy Analyzer CommandsAlphanumeric List of all Legacy Commands with N9061A SupportCommand Description 8566 85688560Series Descriptionfunc
Table Of ContentsDescription 347KSV (Frequency Offset) 348Syntax 348Legacy Products 348Description 348KSx (External Trigger) 349Syntax 349Legacy Produ
4 List of Legacy Analyzer CommandsAlphanumeric List of all Legacy Commands with N9061A SupportCommand Description 8566 85688560Series DescriptionHP85
4 List of Legacy Analyzer CommandsAlphanumeric List of all Legacy Commands with N9061A SupportCommand Description 8566 85688560Series DescriptionLIMI
4 List of Legacy Analyzer CommandsAlphanumeric List of all Legacy Commands with N9061A SupportCommand Description 8566 85688560Series Descriptioninte
4 List of Legacy Analyzer CommandsAlphanumeric List of all Legacy Commands with N9061A SupportCommand Description 8566 85688560Series DescriptionMERG
4 List of Legacy Analyzer CommandsAlphanumeric List of all Legacy Commands with N9061A SupportCommand Description 8566 85688560Series DescriptionMKMI
4 List of Legacy Analyzer CommandsAlphanumeric List of all Legacy Commands with N9061A SupportCommand Description 8566 85688560Series Descriptionmemo
4 List of Legacy Analyzer CommandsAlphanumeric List of all Legacy Commands with N9061A SupportCommand Description 8566 85688560Series DescriptionO3 O
4 List of Legacy Analyzer CommandsAlphanumeric List of all Legacy Commands with N9061A SupportCommand Description 8566 85688560Series DescriptionOT O
4 List of Legacy Analyzer CommandsAlphanumeric List of all Legacy Commands with N9061A SupportCommand Description 8566 85688560Series DescriptionPREA
4 List of Legacy Analyzer CommandsAlphanumeric List of all Legacy Commands with N9061A SupportCommand Description 8566 85688560Series Descriptionrefe
Notices© Agilent Technologies, Inc., 2008-2013No part of this manual may bereproduced in any form or by anymeans (including electronic storageand retr
Table Of ContentsQuery Data Type Codes 357LIMIPURGE (Delete Current Limit Line) 358Syntax 358Legacy Products 358Description 358LIMIREL (Relative Limit
4 List of Legacy Analyzer CommandsAlphanumeric List of all Legacy Commands with N9061A SupportCommand Description 8566 85688560Series Descriptionfrom
4 List of Legacy Analyzer CommandsAlphanumeric List of all Legacy Commands with N9061A SupportCommand Description 8566 85688560Series DescriptionSRCP
4 List of Legacy Analyzer CommandsAlphanumeric List of all Legacy Commands with N9061A SupportCommand Description 8566 85688560Series DescriptionSYNC
4 List of Legacy Analyzer CommandsAlphanumeric List of all Legacy Commands with N9061A SupportCommand Description 8566 85688560Series DescriptionTOIR
4 List of Legacy Analyzer CommandsAlphanumeric List of all Legacy Commands with N9061A SupportCommand Description 8566 85688560Series DescriptionUSTA
5 Legacy Command DescriptionsThis chapter lists all the supported 8560Series, 8566A/B and8568A/B commands in alphanumeric order, and gives briefdetai
5 Legacy Command DescriptionsCommand SyntaxCommand SyntaxCommand syntax is represented pictorially.l Ovals enclose command mnemonics. The command mne
5 Legacy Command DescriptionsCommand SyntaxSyntaxComponent Definition/RangeAnalyzercommandAny command in this chapter, with required parameters and t
5 Legacy Command DescriptionsCommand DescriptionsCommand DescriptionsAll supported commands are listed here, with descriptions and cross-references t
5 Legacy Command DescriptionsA1 [one] (Clear Write for Trace A)A1 [one] (Clear Write for Trace A)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDe
Table Of ContentsM4 [four] (Marker Zoom) 369Syntax 369Legacy Products 369Description 369MA (Marker Amplitude Output) 371Syntax 371Legacy Products 371D
5 Legacy Command DescriptionsA2 [two] (Maximum Hold for Trace A)A2 [two] (Maximum Hold for Trace A)SyntaxLegacy Products8560 series, 8566A/B, 8568A/B
5 Legacy Command DescriptionsA3 [three] (View Mode for Trace A)A3 [three] (View Mode for Trace A)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDe
5 Legacy Command DescriptionsA4 [four] (Blank Trace A)A4 [four] (Blank Trace A)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionBlanks Tr
5 Legacy Command DescriptionsACPALPHA (Adjacent Channel Power Alpha Weighting)ACPALPHA (Adjacent Channel Power Alpha Weighting)SyntaxLegacy Products8
5 Legacy Command DescriptionsACPALTCH (Adjacent Channel Power Alternate Channels)ACPALTCH (Adjacent Channel Power Alternate Channels)SyntaxLegacy Pro
5 Legacy Command DescriptionsACPBRPER (Adjacent Channel Power Burst Period)ACPBRPER (Adjacent Channel Power Burst Period)SyntaxLegacy Products8560 se
5 Legacy Command DescriptionsACPBRWID (Adjacent Channel Power Burst Width)ACPBRWID (Adjacent Channel Power Burst Width)SyntaxLegacy Products8560 seri
5 Legacy Command DescriptionsACPBW (Adjacent Channel Power Bandwidth)ACPBW (Adjacent Channel Power Bandwidth)SyntaxLegacy Products8560 seriesDescript
5 Legacy Command DescriptionsACPCOMPUTE (Adjacent Channel Power Compute)ACPCOMPUTE (Adjacent Channel Power Compute)SyntaxLegacy Products8560 seriesDe
5 Legacy Command DescriptionsACPFRQWT (Adjacent Channel Power Frequency Weighting)ACPFRQWT (Adjacent Channel Power Frequency Weighting)SyntaxLegacy P
Table Of ContentsSyntax 379Legacy Products 379Description 379MINPOS (Minimum X Position) 380Syntax 380Legacy Products 380Description 380MKA (Marker Am
5 Legacy Command DescriptionsACPLOWER (Lower Adjacent Channel Power)ACPLOWER (Lower Adjacent Channel Power)SyntaxLegacy Products8560 seriesDescriptio
5 Legacy Command DescriptionsACPMAX (Maximum Adjacent Channel Power)ACPMAX (Maximum Adjacent Channel Power)SyntaxDescriptionReturns the maximum adjac
5 Legacy Command DescriptionsACPMEAS (Measure Adjacent Channel Power)ACPMEAS (Measure Adjacent Channel Power)SyntaxLegacy Products8560 seriesDescript
5 Legacy Command DescriptionsACPMSTATE (Adjacent Channel Power Measurement State)ACPMSTATE (Adjacent Channel Power Measurement State)SyntaxLegacy Pro
5 Legacy Command DescriptionsACPMSTATE (Adjacent Channel Power Measurement State)Query Data Type CURR|DFLTSCPI Equivalent Commands NonePreset Default
5 Legacy Command DescriptionsACPPWRTX (Adjacent Channel Power Total Power Transmitted)ACPPWRTX (Adjacent Channel Power Total Power Transmitted)Syntax
5 Legacy Command DescriptionsACPRSLTS (Adjacent Channel Power Measurement Results)ACPRSLTS (Adjacent Channel Power Measurement Results)SyntaxLegacy P
5 Legacy Command DescriptionsQuery Data Type DetailsQuery Data Type DetailsAlternateChannelsChannels used for CalculationNumber of Values Returned0l
5 Legacy Command DescriptionsACPSP (Adjacent Channel Power Channel Spacing)ACPSP (Adjacent Channel Power Channel Spacing)SyntaxLegacy Products8560 se
5 Legacy Command DescriptionsACPT (Adjacent Channel Power T Weighting)ACPT (Adjacent Channel Power T Weighting)SyntaxLegacy Products8560 seriesDescri
Table Of ContentsLegacy Products 391Description 391MKMIN (Marker Minimum) 392Syntax 392Legacy Products 392Description 392MKN (Marker Normal) 393Syntax
5 Legacy Command DescriptionsACPUPPER (Upper Adjacent Channel Power)ACPUPPER (Upper Adjacent Channel Power)SyntaxLegacy Products8560 seriesDescriptio
5 Legacy Command DescriptionsADJALL (LO and IF Adjustments)ADJALL (LO and IF Adjustments)SyntaxLegacy Products8560 seriesDescriptionActivates the RF
5 Legacy Command DescriptionsAMB (A minus B into A)AMB (A minus B into A)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionSubtracts the p
5 Legacy Command DescriptionsAMBPL (A minus B plus Display Line into A)AMBPL (A minus B plus Display Line into A)SyntaxLegacy Products8560 series, 85
5 Legacy Command DescriptionsANNOT (Annotation)ANNOT (Annotation)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionTurns on or off all ann
5 Legacy Command DescriptionsAPB (Trace A Plus Trace B to A)APB (Trace A Plus Trace B to A)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescript
5 Legacy Command DescriptionsAT (Input Attenuation)AT (Input Attenuation)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionSpecifies the R
5 Legacy Command DescriptionsAT (Input Attenuation)"(Mech) Atten Step" on page 527)[:SENSE]:POWer[:RF]:ATTenuation:AUTO (OFF|ON|0|1) (see &
5 Legacy Command DescriptionsAUNITS (Absolute Amplitude Units)AUNITS (Absolute Amplitude Units)Syntax8560 series8566A/B, 8568A/BLegacy Products8560 s
5 Legacy Command DescriptionsAUNITS (Absolute Amplitude Units)If your selected remote language is any of the 8560 Series analyzers, and if the AUNITS
Table Of ContentsDescription 402MKRL (Marker to Reference Level) 404Syntax 404Legacy Products 404Description 404MKSP (Marker Span) 405Syntax 405Legacy
5 Legacy Command DescriptionsAUTOCPL (Auto Coupled)AUTOCPL (Auto Coupled)SyntaxLegacy Products8560 seriesDescriptionSets video bandwidth, resolution
5 Legacy Command DescriptionsAXB (Exchange Trace A and Trace B)AXB (Exchange Trace A and Trace B)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDe
5 Legacy Command DescriptionsB1 [one] (Clear Write for Trace B)B1 [one] (Clear Write for Trace B)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDe
5 Legacy Command DescriptionsB2 [two] (Maximum Hold for Trace B)B2 [two] (Maximum Hold for Trace B)SyntaxLegacy Products8560 series, 8566A/B, 8568A/B
5 Legacy Command DescriptionsB3 [three] (View Mode for Trace B)B3 [three] (View Mode for Trace B)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDe
5 Legacy Command DescriptionsB4 [four] (Blank Trace B)B4 [four] (Blank Trace B)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionBlanks Tr
5 Legacy Command DescriptionsBL (Trace B minus Display Line to Trace B)BL (Trace B minus Display Line to Trace B)SyntaxLegacy Products8566A/B, 8568A/
5 Legacy Command DescriptionsBLANK (Blank Trace)BLANK (Blank Trace)Syntax8560 Series:8566A/B, 8568A/B:Legacy Products8560 series, 8566A/B, 8568A/BDes
5 Legacy Command DescriptionsBLANK (Blank Trace)(See "View/Blank " on page 1344)Preset TRB, TRC Blank.Notes The functions of BLANK are iden
5 Legacy Command DescriptionsBML (Trace B Minus Display Line)BML (Trace B Minus Display Line)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescri
Table Of ContentsMT1 [one] (Marker Track On) 414Syntax 414Legacy Products 414Description 414MXMH (Maximum Hold) 415Syntax 415Legacy Products 415Descri
5 Legacy Command DescriptionsBTC (Transfer Trace B to Trace C)BTC (Transfer Trace B to Trace C)SyntaxLegacy Products8566A/B, 8568A/BDescriptionTransf
5 Legacy Command DescriptionsBXC (Exchange Trace B and Trace C)BXC (Exchange Trace B and Trace C)SyntaxLegacy Products8566A/B, 8568A/BDescriptionExch
5 Legacy Command DescriptionsC1 [one] (Set A Minus B Mode Off)C1 [one] (Set A Minus B Mode Off)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDesc
5 Legacy Command DescriptionsC2 [two] (A Minus B Into A)C2 [two] (A Minus B Into A)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionSubtr
5 Legacy Command DescriptionsCA (Couple Attenuation)CA (Couple Attenuation)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionDuring normal
5 Legacy Command DescriptionsCARROFF (Carrier Off Power)CARROFF (Carrier Off Power)SyntaxLegacy Products8560 seriesDescriptionMeasures the average an
5 Legacy Command DescriptionsCARRON (Carrier On Power)CARRON (Carrier On Power)SyntaxLegacy Products8560 seriesDescriptionMeasures the average power
5 Legacy Command DescriptionsCF (Center Frequency)CF (Center Frequency)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionSpecifies the val
5 Legacy Command DescriptionsCF (Center Frequency)Default unit is HZ.CF UPCF DNStep size: see Description above.CF OACF?Query Data Type <freq>
5 Legacy Command DescriptionsCHANNEL (Channel Selection)CHANNEL (Channel Selection)SyntaxLegacy Products8560 seriesDescriptionIncrements or decrement
Table Of ContentsLegacy Products 424Description 424OCCUP (Percent Occupied Power Bandwidth) 425Syntax 425Legacy Products 425Description 425OL (Output
5 Legacy Command DescriptionsCHANPWR (Channel Power)CHANPWR (Channel Power)SyntaxLegacy Products8560 seriesDescriptionMeasures the power within the s
5 Legacy Command DescriptionsCHPWRBW (Channel Power Bandwidth)CHPWRBW (Channel Power Bandwidth)SyntaxLegacy Products8560 seriesDescriptionQueries or
5 Legacy Command DescriptionsCLRAVG (Clear Average)CLRAVG (Clear Average)SyntaxLegacy Products8566A/B, 8568A/BDescriptionRestarts the VAVG command by
5 Legacy Command DescriptionsCLRW (Clear Write)CLRW (Clear Write)Syntax8560 series8566A/B, 8568A/BLegacy Products8560 series, 8566A/B, 8568A/BDescrip
5 Legacy Command DescriptionsCLRW (Clear Write)The following table describes the parameters set by N9061A in the X-series instrument when thelegacy c
5 Legacy Command DescriptionsCONTS (Continuous Sweep)CONTS (Continuous Sweep)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionSets the in
5 Legacy Command DescriptionsCOUPLE (Input Coupling)COUPLE (Input Coupling)SyntaxLegacy Products8560 seriesDescriptionSelects AC or DC coupling.Forma
5 Legacy Command DescriptionsCR (Couple Resolution Bandwidth)CR (Couple Resolution Bandwidth)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescri
5 Legacy Command DescriptionsCS (Couple Frequency Step Size)CS (Couple Frequency Step Size)SyntaxLegacy Products8566A/B, 8568A/BDescriptionCouples th
5 Legacy Command DescriptionsCT (Couple Sweep Time)CT (Couple Sweep Time)SyntaxLegacy Products8566A/B, 8568A/BDescriptionCouples the sweep time to th
Table Of ContentsDescription 436R1 [one] (Illegal Command SRQ) 438Syntax 438Legacy Products 438Description 438R2 [two] (End-of-Sweep SRQ) 439Syntax 43
5 Legacy Command DescriptionsCV (Couple Video Bandwidth)CV (Couple Video Bandwidth)SyntaxLegacy Products8566A/B, 8568A/BDescriptionCouples the video
5 Legacy Command DescriptionsDA (Display Address)DA (Display Address)SyntaxLegacy Products8566A/B, 8568A/BDescriptionReturns the contents of the give
5 Legacy Command DescriptionsDELMKBW (Occupied Power Bandwidth Within Delta Marker)DELMKBW (Occupied Power Bandwidth Within Delta Marker)SyntaxLegacy
5 Legacy Command DescriptionsDET (Detection Mode)DET (Detection Mode)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionSelects the type of
5 Legacy Command DescriptionsDL (Display Line)DL (Display Line)Syntax8560 series:8566A/B, 8568A/B:Legacy Products8560 series, 8566A/B, 8568A/B274 Rem
5 Legacy Command DescriptionsDL (Display Line)DescriptionDefines the level of the display line and displays it on the instrument screen.Format DL <
5 Legacy Command DescriptionsDLE (Display Line Enable)DLE (Display Line Enable)SyntaxLegacy Products8566A/B, 8568A/BDescriptionEnables or disables th
5 Legacy Command DescriptionsDLYSWP (Delay Sweep)DLYSWP (Delay Sweep)SyntaxLegacy Products8560 seriesDescriptionDelays the start of the sweep until t
5 Legacy Command DescriptionsDONE (Done)DONE (Done)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionAllows you to determine when the inst
5 Legacy Command DescriptionsDR (Display Read)DR (Display Read)SyntaxLegacy Products8566A/B, 8568A/BDescriptionSends the contents of the current disp
Table Of ContentsRL (Reference Level) 449Syntax 449Legacy Products 449Description 450RMS (Root Mean Square Value) 451Syntax 451Legacy Products 451Desc
5 Legacy Command DescriptionsE1[one] (Peak Marker)E1[one] (Peak Marker)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionPositions the mar
5 Legacy Command DescriptionsE2 [two] (Marker to Center Frequency)E2 [two] (Marker to Center Frequency)SyntaxLegacy Products8560 series, 8566A/B, 856
5 Legacy Command DescriptionsE3 [three] (Delta Marker Step Size)E3 [three] (Delta Marker Step Size)SyntaxLegacy Products8560 series, 8566A/B, 8568A/B
5 Legacy Command DescriptionsE4 [four] (Marker to Reference Level)E4 [four] (Marker to Reference Level)SyntaxLegacy Products8560 series, 8566A/B, 856
5 Legacy Command DescriptionsEDITDONE (Edit Done)EDITDONE (Edit Done)SyntaxLegacy Products8560 seriesDescriptionThis command is used at the completio
5 Legacy Command DescriptionsEDITLIML (Edit Limit Line)EDITLIML (Edit Limit Line)SyntaxLegacy Products8560 seriesDescriptionThis command is used to i
5 Legacy Command DescriptionsERR (Error)ERR (Error)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionThe ERR? query returns a list of thre
5 Legacy Command DescriptionsERR (Error)X-Series Error Code Description8560 Series Error CodeDescription42 RF Alignment Failure 758 SYSTEM: Unknownsy
5 Legacy Command DescriptionsERR (Error)X-Series Error Code Description8560 Series Error CodeDescription521 External Ref missing or out of range 905,
5 Legacy Command DescriptionsET (Elapsed Time)ET (Elapsed Time)SyntaxLegacy Products8560 seriesDescriptionReturns to the controller the elapsed time
Table Of ContentsSyntax 461Legacy Products 461Description 461SMOOTH (Smooth Trace) 462Syntax 462Legacy Products 462Description 462SNGLS (Single Sweep)
5 Legacy Command DescriptionsEX (Exchange Trace A and Trace B)EX (Exchange Trace A and Trace B)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDesc
5 Legacy Command DescriptionsFA (Start Frequency)FA (Start Frequency)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionSpecifies the start
5 Legacy Command DescriptionsFA (Start Frequency)function to the start frequency.FA?Query Data Type <real> in HZ.SCPI Equivalent Commands [:SEN
5 Legacy Command DescriptionsFB (Stop Frequency)FB (Stop Frequency)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionSpecifies the stop fr
5 Legacy Command DescriptionsFB (Stop Frequency)FB?Query Data Type <real> in HZ.SCPI Equivalent Commands [:SENSE]:FREQuency:STOP <real> (
5 Legacy Command DescriptionsFDSP (Frequency Display Off)FDSP (Frequency Display Off)SyntaxLegacy Products8560 seriesDescriptionTurns the frequency a
5 Legacy Command DescriptionsFOFFSET (Frequency Offset)FOFFSET (Frequency Offset)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionSelects
5 Legacy Command DescriptionsFOFFSET (Frequency Offset)FOFFSET?Query Data Type <real>SCPI Equivalent Commands [:SENSE]:FREQuency:OFFSet <num
5 Legacy Command DescriptionsFPKA (Fast Preselector Peak)FPKA (Fast Preselector Peak)SyntaxLegacy Products8566A/BDescriptionAutomatically adjusts the
5 Legacy Command DescriptionsFREF (Frequency Reference)FREF (Frequency Reference)SyntaxLegacy Products8560 seriesDescriptionSpecifies whether an exte
Table Of ContentsTable Of ContentsN9061A Remote Language Compatibility Measurement Application User's &Programmer'sReference 1Table Of
Table Of ContentsLegacy Products 474Description 474SV (Save State) 475Syntax 475Legacy Products 475Description 475SWPCPL (Sweep Couple) 476Syntax 476L
5 Legacy Command DescriptionsFS (Full Span)FS (Full Span)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionl 8560 series: Sets the frequen
5 Legacy Command DescriptionsFS (Full Span)N9030A-503 N9030A-508 N9030A-513 N9030A-526Remote Language Frequency Range Frequency Range Frequency Range
5 Legacy Command DescriptionsFS (Full Span)N9010A-503 N9010A-507 N9010A-513 N9010A-526Remote Language Frequency Range Frequency Range Frequency Range
5 Legacy Command DescriptionsGATE (Gate)GATE (Gate)SyntaxPreset State: GATE OFFLegacy Products8560 seriesDescriptionTurns the time-gating function on
5 Legacy Command DescriptionsGATECTL (Gate Control)GATECTL (Gate Control)SyntaxLegacy Products8560 seriesDescriptionSelects between the edge and leve
5 Legacy Command DescriptionsGD (Gate Delay)GD (Gate Delay)SyntaxLegacy Products8560 seriesDescriptionSets the delay time from when the gate trigger
5 Legacy Command DescriptionsGL (Gate Length)GL (Gate Length)SyntaxLegacy Products8560 seriesDescriptionSets the length of time the time gate is turn
5 Legacy Command DescriptionsGP (Gate Polarity)GP (Gate Polarity)SyntaxLegacy Products8560 seriesDescriptionSets the polarity (positive or negative)
5 Legacy Command DescriptionsGRAT (Graticule)GRAT (Graticule)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionTurns the graticule on or o
5 Legacy Command DescriptionsHD (Hold Data Entry)HD (Hold Data Entry)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionDisables data entry
Table Of ContentsDescription 483TH (Threshold) 484Syntax 484Legacy Products 484Description 484THE (Threshold Enable) 486Syntax 486Legacy Products 486D
5 Legacy Command DescriptionsI1 [one] (Set RF Coupling to DC)I1 [one] (Set RF Coupling to DC)SyntaxLegacy Products8568A/BDescriptionSets the RF coupl
5 Legacy Command DescriptionsI1 [one] (Set RF Coupling to DC)DC Coupled Range AC Coupled RangeInstrument Model (N9020A) Min. Freq. Max. Freq. Min. Fr
5 Legacy Command DescriptionsI2 [two] (Set RF Coupling to AC)I2 [two] (Set RF Coupling to AC)SyntaxLegacy Products8568A/BDescriptionSets the RF coupl
5 Legacy Command DescriptionsI2 [two] (Set RF Coupling to AC)DC Coupled Range AC Coupled RangeInstrument Model (N9010A) Min. Freq. Max. Freq. Min. Fr
5 Legacy Command DescriptionsID (Identify)ID (Identify)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionThe ID? query returns the current
5 Legacy Command DescriptionsIP (Instrument Preset)IP (Instrument Preset)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionPerforms an ins
5 Legacy Command DescriptionsKS= (8566A/B: Automatic Preselector Tracking, 8568A/B: Marker Counter Resolution)KS= (8566A/B: Automatic Preselector Tra
5 Legacy Command DescriptionsKS( (Lock Registers)KS( (Lock Registers)SyntaxLegacy Products8566A/B, 8568A/BDescriptionSecures the contents of state re
5 Legacy Command DescriptionsKS, (Mixer Level)KS, (Mixer Level)SyntaxLegacy Products8566A/B, 8568A/BDescriptionSpecifies the maximum signal level tha
5 Legacy Command DescriptionsKS) (Unlock Registers)KS) (Unlock Registers)SyntaxLegacy Products8566A/B, 8568A/BDescriptionUnlocks the state registers,
Table Of ContentsTRIGPOL (Trigger Polarity) 495Syntax 495Legacy Products 495Description 495TRSTAT (Trace State) 496Syntax 496Legacy Products 496Descri
5 Legacy Command DescriptionsKSA (Amplitude in dBm)KSA (Amplitude in dBm)SyntaxLegacy Products8566A/B, 8568A/BDescriptionSets the amplitude readout (
5 Legacy Command DescriptionsKSa (Normal Detection)KSa (Normal Detection)SyntaxLegacy Products8566A/B, 8568A/BDescriptionSelects normal input detecti
5 Legacy Command DescriptionsKSB (Amplitude in dBmV)KSB (Amplitude in dBmV)SyntaxLegacy Products8566A/B, 8568A/BDescriptionSets the amplitude readout
5 Legacy Command DescriptionsKSb (Positive Peak Detection)KSb (Positive Peak Detection)SyntaxLegacy Products8566A/B, 8568A/BDescriptionEnables positi
5 Legacy Command DescriptionsKSC (Amplitude in dBμV)KSC (Amplitude in dBμV)SyntaxLegacy Products8566A/B, 8568A/BDescriptionSets the amplitude readout
5 Legacy Command DescriptionsKSc (A Plus B to A)KSc (A Plus B to A)SyntaxLegacy Products8566A/B, 8568A/BDescriptionPerforms a point-by-point addition
5 Legacy Command DescriptionsKSD (Amplitude in Volts)KSD (Amplitude in Volts)SyntaxLegacy Products8566A/B, 8568A/BDescriptionSets the amplitude reado
5 Legacy Command DescriptionsKSd (Negative Peak Detection)KSd (Negative Peak Detection)SyntaxLegacy Products8566A/B, 8568A/BDescriptionSelects negati
5 Legacy Command DescriptionsKSE (Title Mode)KSE (Title Mode)SyntaxLegacy Products8566A/B, 8568A/BDescriptionActivates the title mode, writing a mess
5 Legacy Command DescriptionsKSe (Sample Detection)KSe (Sample Detection)SyntaxLegacy Products8566A/B, 8568A/BDescriptionSelects sample input detecti
Table Of ContentsSyntax 509Legacy Products 509Description 5096 RLC Swept SA Measurement Front-Panel &SCPI Reference 511AMPTD Y Scale 516Reference
5 Legacy Command DescriptionsKSG (Video Averaging On)KSG (Video Averaging On)SyntaxLegacy Products8566A/B, 8568A/BDescriptionEnables video averaging.
5 Legacy Command DescriptionsKSg (Display Off)KSg (Display Off)SyntaxLegacy Products8566A/B, 8568A/BDescriptionTurns the instrument’s display Off.For
5 Legacy Command DescriptionsKSH (Video Averaging Off)KSH (Video Averaging Off)SyntaxLegacy Products8566A/B, 8568A/BDescriptionSwitches video averagi
5 Legacy Command DescriptionsKSh (Display On)KSh (Display On)SyntaxLegacy Products8566A/B, 8568A/BDescriptionTurns the instrument’s display On.Format
5 Legacy Command DescriptionsKSi (Exchange Trace B and Trace C)KSi (Exchange Trace B and Trace C)SyntaxLegacy Products8566A/B, 8568A/BDescriptionExch
5 Legacy Command DescriptionsKSj (View Trace C)KSj (View Trace C)SyntaxLegacy Products8566A/B, 8568A/BDescriptionDisplays Trace C.Format KSjQuery Dat
5 Legacy Command DescriptionsKSK (Marker to Next Peak)KSK (Marker to Next Peak)SyntaxLegacy Products8566A/B, 8568A/BDescriptionIf there is a marker o
5 Legacy Command DescriptionsKSk (Blank Trace C)KSk (Blank Trace C)SyntaxLegacy Products8566A/B, 8568A/BDescriptionBlanks Trace C.Format KSkQuery Dat
5 Legacy Command DescriptionsKSL (Marker Noise Off)KSL (Marker Noise Off)SyntaxLegacy Products8566A/B, 8568A/BDescriptionDisables the noise density f
5 Legacy Command DescriptionsKSl (Transfer Trace B to Trace C)KSl (Transfer Trace B to Trace C)SyntaxLegacy Products8566A/B, 8568A/BDescriptionTransf
Table Of ContentsAuto Tune 572Center Freq 573Start Freq 579Stop Freq 581CF Step 583Freq Offset 584Input/Output 587Input/Output variables - Preset beha
5 Legacy Command DescriptionsKSM (Marker Noise On)KSM (Marker Noise On)SyntaxLegacy Products8566A/B, 8568A/BDescriptionDisplays the noise density at
5 Legacy Command DescriptionsKSm (Graticule Off)KSm (Graticule Off)SyntaxLegacy Products8566A/B, 8568A/BDescriptionBlanks the graticule on the instru
5 Legacy Command DescriptionsKSN (Marker Minimum)KSN (Marker Minimum)SyntaxLegacy Products8566A/B, 8568A/BDescriptionMoves the marker to the minimum
5 Legacy Command DescriptionsKSn (Graticule On)KSn (Graticule On)SyntaxLegacy Products8566A/B, 8568A/BDescriptionTurns on the graticule on the instru
5 Legacy Command DescriptionsKSO (Marker Span)KSO (Marker Span)SyntaxLegacy Products8566A/B, 8568A/BDescriptionThis command operates only when the de
5 Legacy Command DescriptionsKSo (Annotation Off)KSo (Annotation Off)SyntaxLegacy Products8566A/B, 8568A/BDescriptionBlanks the annotation on the ins
5 Legacy Command DescriptionsKSp (Annotation On)KSp (Annotation On)SyntaxLegacy Products8566A/B, 8568A/BDescriptionActivates the annotation on the in
5 Legacy Command DescriptionsKST (Fast Preset)KST (Fast Preset)SyntaxLegacy Products8566A/B, 8568A/BDescriptionPerforms an instrument preset, setting
5 Legacy Command DescriptionsKSV (Frequency Offset)KSV (Frequency Offset)SyntaxLegacy Products8566A/B, 8568A/BDescriptionAllows you to specify a valu
5 Legacy Command DescriptionsKSx (External Trigger)KSx (External Trigger)SyntaxLegacy Products8566A/B, 8568A/BDescriptionActivates the normal externa
Table Of ContentsFixed marker functions 730Interval Markers 730Band Function Backwards Compatibility 7311. Marker Mode compatibility 7332. Span Pair C
5 Legacy Command DescriptionsKSy (Video Trigger)KSy (Video Trigger)SyntaxLegacy Products8566A/B, 8568A/BDescriptionActivates the normal video trigger
5 Legacy Command DescriptionsKSZ (Reference Level Offset)KSZ (Reference Level Offset)SyntaxLegacy Products8566A/B, 8568A/BDescriptionOffsets all ampl
5 Legacy Command DescriptionsL0 [zero] (Display Line Off)L0 [zero] (Display Line Off)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionDis
5 Legacy Command DescriptionsLF (Low Frequency Preset)LF (Low Frequency Preset)SyntaxLegacy Products8566A/BDescriptionPerforms a low frequency preset
5 Legacy Command DescriptionsLG (Logarithmic Scale)LG (Logarithmic Scale)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionSpecifies the a
5 Legacy Command DescriptionsLIMF (Limit Line Frequency Value)LIMF (Limit Line Frequency Value)SyntaxLegacy Products8560 seriesDescriptionThis comman
5 Legacy Command DescriptionsLIMIFAIL (Limits Failed)LIMIFAIL (Limits Failed)SyntaxLegacy Products8560 seriesDescriptionReturns a number between 0 an
5 Legacy Command DescriptionsQuery Data Type CodesQuery Data Type CodesResult Meaning0 The active trace passed both the upper and the lower limit tes
5 Legacy Command DescriptionsLIMIPURGE (Delete Current Limit Line)LIMIPURGE (Delete Current Limit Line)SyntaxLegacy Products8560 seriesDescriptionDel
5 Legacy Command DescriptionsLIMIREL (Relative Limit Lines)LIMIREL (Relative Limit Lines)SyntaxLegacy Products8560 seriesDescriptionSpecifies whether
Table Of ContentsFFT IF Gain 842Analog Demod Tune & Listen 845Noise Source 853Meas Preset 859Mode 860More Information 861Spectrum Analyzer 862EMI
5 Legacy Command DescriptionsLIML (Lower-Limit Amplitude)LIML (Lower-Limit Amplitude)SyntaxLegacy Products8560 seriesDescriptionAssigns the lower-lim
5 Legacy Command DescriptionsLIMTSL (Slope Limit Line)LIMTSL (Slope Limit Line)SyntaxLegacy Products8560 seriesDescriptionMakes the selected limit-li
5 Legacy Command DescriptionsLIMU (Upper-Limit Amplitude)LIMU (Upper-Limit Amplitude)SyntaxLegacy Products8560 seriesDescriptionAssigns the upper-lim
5 Legacy Command DescriptionsLN (Linear Scale)LN (Linear Scale)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionScales the amplitude (ver
5 Legacy Command DescriptionsM1 [one] (Marker Off)M1 [one] (Marker Off)SyntaxLegacy Products8566A/B, 8568A/BDescriptionBlanks any markers showing on
5 Legacy Command DescriptionsM2 [two] (Marker Normal)M2 [two] (Marker Normal)SyntaxLegacy Products8566A/B, 8568A/BDescriptionMoves the active marker
5 Legacy Command DescriptionsM2 [two] (Marker Normal)Query Data Type <real>. See "MKF (Marker Frequency)" on page 387.SCPI Equivalent
5 Legacy Command DescriptionsM3 [three] (Delta Marker)M3 [three] (Delta Marker)SyntaxLegacy Products8566A/B, 8568A/BDescriptionComputes the frequency
5 Legacy Command DescriptionsM3 [three] (Delta Marker)Format M3 <real>HZ|KHZ|MHZ|GHZ|KZ|MZ|GZ|S|MS|US|SCM3 UP|DNUP or DN increments 10% of span
5 Legacy Command DescriptionsM4 [four] (Marker Zoom)M4 [four] (Marker Zoom)SyntaxLegacy Products8566A/B, 8568A/BDescriptionThis command increases or
Table Of ContentsMode Preset 883How-To Preset 884Mode Setup 886HP8560 series, HP8566/68 886Cmd Error 887Logging 888Preferences 889Restore Mode Default
5 Legacy Command DescriptionsM4 [four] (Marker Zoom)M4 OAThe OA option only returns the current value to the controller; it does not set the activefu
5 Legacy Command DescriptionsMA (Marker Amplitude Output)MA (Marker Amplitude Output)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionRet
5 Legacy Command DescriptionsMC0 [zero] (MarkerFrequencyCounterOff)MC0 [zero] (MarkerFrequencyCounterOff)SyntaxLegacy Products8568A/BDescriptio
5 Legacy Command DescriptionsMC1 [one] (MarkerFrequencyCounterOn)MC1 [one] (MarkerFrequencyCounterOn)SyntaxLegacy Products8568A/BDescriptionTur
5 Legacy Command DescriptionsMDS (Measurement Data Size)MDS (Measurement Data Size)SyntaxLegacy Products8566A/B, 8568A/BDescriptionFormats binary dat
5 Legacy Command DescriptionsMEAN (Trace Mean)MEAN (Trace Mean)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionReturns the mean value of
5 Legacy Command DescriptionsMEANPWR (Mean Power measurement)MEANPWR (Mean Power measurement)SyntaxLegacy Products8560 seriesDescriptionMeasures the
5 Legacy Command DescriptionsMEAS (Meas)MEAS (Meas)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionReturns the current sweep status.l If
5 Legacy Command DescriptionsMF (Marker Frequency Output)MF (Marker Frequency Output)Syntax8560 series:8566A/B, 8568A/B:Legacy Products8560 series, 8
5 Legacy Command DescriptionsMINH (Minimum Hold)MINH (Minimum Hold)SyntaxLegacy Products8560 seriesDescriptionUpdates the chosen trace with the minim
Table Of ContentsScreen Image 1113Mass Storage Catalog (Remote Command Only) 1119Mass Storage Change Directory (Remote Command Only) 1119Mass Storage
5 Legacy Command DescriptionsMINPOS (Minimum X Position)MINPOS (Minimum X Position)SyntaxLegacy Products8566A/B, 8568A/BDescriptionReturns the X co-o
5 Legacy Command DescriptionsMKA (Marker Amplitude)MKA (Marker Amplitude)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionReturns the amp
5 Legacy Command DescriptionsMKACT (Activate Marker)MKACT (Activate Marker)SyntaxLegacy Products8566A/B, 8568A/BDescriptionSpecifies the active marke
5 Legacy Command DescriptionsMKBW (Marker Bandwidth)MKBW (Marker Bandwidth)SyntaxLegacy Products8560 seriesDescriptionReturns the bandwidth at the sp
5 Legacy Command DescriptionsMKCF (Marker to Center Frequency)MKCF (Marker to Center Frequency)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDesc
5 Legacy Command DescriptionsMKD (Marker Delta)MKD (Marker Delta)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionComputes the frequency
5 Legacy Command DescriptionsMKD (Marker Delta)Format MKD <real>HZ|KHZ|MHZ|GHZ|KZ|MZ|GZ|S|MS|US|SCMKD UP|DNUP or DN specifies 10% of the curren
5 Legacy Command DescriptionsMKF (Marker Frequency)MKF (Marker Frequency)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionSpecifies the f
5 Legacy Command DescriptionsMKF (Marker Frequency)MKF?Query Data Type 8560 Series: The data is returned in ASCII format.For all other languages, the
5 Legacy Command DescriptionsMKFC (Marker Counter)MKFC (Marker Counter)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionTurns on or off t
Table Of ContentsPower On 1251Alignments 1260I/O Config 1294Restore Defaults 1303Control Panel… 1308Licensing… 1309Security 1312Diagnostics 1313Servic
5 Legacy Command DescriptionsMKFCR (Marker Counter Resolution)MKFCR (Marker Counter Resolution)Syntax8560 series:8566A/B, 8568A/B:390 Remote Language
5 Legacy Command DescriptionsMKFCR (Marker Counter Resolution)Legacy Products8560 series, 8566A/B, 8568A/BDescriptionSets the resolution of the marke
5 Legacy Command DescriptionsMKMIN (Marker Minimum)MKMIN (Marker Minimum)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionMoves the activ
5 Legacy Command DescriptionsMKN (Marker Normal)MKN (Marker Normal)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionMoves the active mark
5 Legacy Command DescriptionsMKN (Marker Normal)UP or DN specifies 10% of the current span.MKN OAMKN?Query Data Type See "MKF (Marker Frequency)
5 Legacy Command DescriptionsMKNOISE (Marker Noise)MKNOISE (Marker Noise)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionDisplays the av
5 Legacy Command DescriptionsMKOFF (Marker Off)MKOFF (Marker Off)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionTurns off either the ac
5 Legacy Command DescriptionsMKP (Marker Position)MKP (Marker Position)SyntaxLegacy Products8566A/B, 8568A/BDescriptionSpecifies the marker position
5 Legacy Command DescriptionsMKPK (Marker Peak)MKPK (Marker Peak)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionExecuting MKPK HI, or s
5 Legacy Command DescriptionsMKPK (Marker Peak)Peak)" on page 336, except that KSK does not take in to account the marker peakexcursion or marke
Table Of ContentsUnits 62User-defined Functions 62Supported Commands 62EP Parameter 63OA Parameter 63Handling of Unsupported Commands and Queries 63Ha
Table Of ContentsRF Trigger Source 1397I/Q Trigger Source 1398More Information 1399Free Run 1400Video (IF Envelope) 1401Line 1405External 1 1407Extern
5 Legacy Command DescriptionsMKPT (Marker Threshold)MKPT (Marker Threshold)SyntaxLegacy Products8560 seriesDescriptionSets the minimum amplitude leve
5 Legacy Command DescriptionsMKPX (Marker Peak Excursion)MKPX (Marker Peak Excursion)SyntaxPreset State: 6 dBLegacy Products8560 series, 8566A/B, 856
5 Legacy Command DescriptionsMKREAD (Marker Readout)MKREAD (Marker Readout)SyntaxLegacy Products8566A/B, 8568A/BDescriptionSelects the type of active
5 Legacy Command DescriptionsMKREAD (Marker Readout)MKREADType Non-Zero SpanNon-Zero SpanDelta Zero Span Zero Span DeltaPER Period offrequency(Pulsem
5 Legacy Command DescriptionsMKRL (Marker to Reference Level)MKRL (Marker to Reference Level)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescri
5 Legacy Command DescriptionsMKSP (Marker Span)MKSP (Marker Span)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionThis command operates o
5 Legacy Command DescriptionsMKSS (Marker to Step Size)MKSS (Marker to Step Size)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionSets th
5 Legacy Command DescriptionsMKT (Marker Time)MKT (Marker Time)SyntaxLegacy Products8560 seriesDescriptionPlaces a marker at a position that correspo
5 Legacy Command DescriptionsMKTRACE (Marker Trace)MKTRACE (Marker Trace)SyntaxLegacy Products8566A/B, 8568A/BDescriptionMoves the active marker to t
5 Legacy Command DescriptionsMKTRACK (Marker Track)MKTRACK (Marker Track)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionMoves the signa
1 About the AnalyzerThe X-Series signal analyzer measures and monitors complexRF and microwave signals. Analog baseband analysis isavailable on MXA. T
5 Legacy Command DescriptionsMKTYPE (Marker Type)MKTYPE (Marker Type)SyntaxLegacy Products8566A/B, 8568A/BDescriptionSpecifies the type of marker.Typ
5 Legacy Command DescriptionsML (Mixer Level)ML (Mixer Level)Syntax8560 series:8566A/B, 8568A/B:Legacy Products8560 series, 8566A/B, 8568A/BDescripti
5 Legacy Command DescriptionsML (Mixer Level)l Mixer Level = Ref. Level - Attenuation + Ext. Amplifier GainThe external amplifier gain is not preset
5 Legacy Command DescriptionsMT0 [zero] (Marker Track Off)MT0 [zero] (Marker Track Off)SyntaxLegacy Products8566A/B, 8568A/BDescriptionDisables the m
5 Legacy Command DescriptionsMT1 [one] (Marker Track On)MT1 [one] (Marker Track On)SyntaxLegacy Products8566A/B, 8568A/BDescriptionMoves the signal o
5 Legacy Command DescriptionsMXMH (Maximum Hold)MXMH (Maximum Hold)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionUpdates each trace el
5 Legacy Command DescriptionsNORMLIZE (Normalize Trace Data)NORMLIZE (Normalize Trace Data)SyntaxLegacy Products8560 seriesDescriptionActivates or de
5 Legacy Command DescriptionsNORMLIZE (Normalize Trace Data)(See "Normalize On/Off" on page 1381)Preset OFFCouplings NORMLIZE sets Trace B
5 Legacy Command DescriptionsNRL (Normalized Reference Level)NRL (Normalized Reference Level)SyntaxLegacy Products8560 seriesDescriptionSets the norm
5 Legacy Command DescriptionsNRPOS (Normalized Reference Position)NRPOS (Normalized Reference Position)SyntaxLegacy Products8560 seriesDescriptionAdj
1 About the AnalyzerInstalling Application SoftwareInstalling Application SoftwareIf you want to install a measurement application after your initial
5 Legacy Command DescriptionsO1 [one] (Format - Display Units)O1 [one] (Format - Display Units)SyntaxLegacy Products8566A/B, 8568A/BDescriptionTransm
5 Legacy Command DescriptionsO2 [two] (Format - Two 8-Bit Bytes)O2 [two] (Format - Two 8-Bit Bytes)SyntaxLegacy Products8566A/B, 8568A/BDescriptionTr
5 Legacy Command DescriptionsO3 [three] (Format - Real Amplitude Units)O3 [three] (Format - Real Amplitude Units)SyntaxLegacy Products8566A/B, 8568A/
5 Legacy Command DescriptionsO4 [four] (Format - One 8-Bit Byte)O4 [four] (Format - One 8-Bit Byte)SyntaxLegacy Products8566A/B, 8568A/BDescriptionTr
5 Legacy Command DescriptionsOA or ? (Query Active Function)OA or ? (Query Active Function)Legacy Products8566A/B, 8568A/BDescriptionQuery active fun
5 Legacy Command DescriptionsOCCUP (Percent Occupied Power Bandwidth)OCCUP (Percent Occupied Power Bandwidth)SyntaxLegacy Products8560 seriesDescript
5 Legacy Command DescriptionsOL (Output Learn String)OL (Output Learn String)SyntaxLegacy Products8566A/B, 8568A/BDescriptionTransmits information to
5 Legacy Command DescriptionsOL (Output Learn String)Byte Support Information20 Supported: Trigger Mode, Sweep Mode, TRB Clearwrite statusUnsupported
5 Legacy Command DescriptionsOL (Output Learn String)Format OL <80-byte string>OL?Query Data Type See table above.SCPI Equivalent Commands None
5 Legacy Command DescriptionsOT (Output Trace Annotations)OT (Output Trace Annotations)SyntaxLegacy Products8566A/B, 8568A/BDescriptionSends 32 chara
1 About the AnalyzerInstalling Application SoftwareInstalling a license key for the selected application can be done automatically using a USBmemory
5 Legacy Command DescriptionsOT (Output Trace Annotations)Index Content20 "PL1 UNLOCK"21 "PL2 UNLOCK"22 "Y-I-0 UNLOCK"2
5 Legacy Command DescriptionsPEAKS (Peaks)PEAKS (Peaks)Syntax8560 series:8566A/B, 8568A/B:Legacy Products8560 series, 8566A/B, 8568A/BDescriptionSort
5 Legacy Command DescriptionsPKPOS (Peak Position)PKPOS (Peak Position)SyntaxLegacy Products8568DescriptionReturns the X co-ordinate value of the max
5 Legacy Command DescriptionsPLOT (Plot)PLOT (Plot)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionAllows you transfer trace data, grati
5 Legacy Command DescriptionsPP (Preselector Peak)PP (Preselector Peak)SyntaxLegacy Products8560 series, 8566A/BDescriptionOptimizes preselector trac
5 Legacy Command DescriptionsPRINT (Print)PRINT (Print)SyntaxLegacy Products8560 seriesDescriptionTransfers trace data, graticule and annotation of t
5 Legacy Command DescriptionsPWRBW (Power Bandwidth)PWRBW (Power Bandwidth)Syntax8560 Series:8566A/B, 8568A/B:Legacy Products8560 series, 8566A/B, 85
5 Legacy Command DescriptionsPWRBW (Power Bandwidth)SCPI Equivalent Commands NoneNotes If the percent total power is 100%, the power bandwidth equals
5 Legacy Command DescriptionsR1 [one] (Illegal Command SRQ)R1 [one] (Illegal Command SRQ)SyntaxLegacy Products8566A/B, 8568A/BDescriptionDeactivates
5 Legacy Command DescriptionsR2 [two] (End-of-Sweep SRQ)R2 [two] (End-of-Sweep SRQ)SyntaxLegacy Products8566A/B, 8568A/BDescriptionActivates the end-
1 About the AnalyzerX-Series Options and AccessoriesX-Series Options and AccessoriesYou can view an online list of available Options and Accessories
5 Legacy Command DescriptionsR3 [three] (Hardware Broken SRQ)R3 [three] (Hardware Broken SRQ)SyntaxLegacy Products8566A/B, 8568A/BDescriptionActivate
5 Legacy Command DescriptionsR4 [four] (Units-Key-Pressed SRQ)R4 [four] (Units-Key-Pressed SRQ)SyntaxLegacy Products8566A/B, 8568A/BDescriptionActiva
5 Legacy Command DescriptionsRB (Resolution Bandwidth)RB (Resolution Bandwidth)Syntax8560 series:8566A/B, 8568A/B:Legacy Products8560 series, 8566A/B
5 Legacy Command DescriptionsRB (Resolution Bandwidth)bandwidths, and sweep time are normally coupled, but executing RB decouples them. Execute "
5 Legacy Command DescriptionsRBR (Resolution Bandwidth to Span Ratio)RBR (Resolution Bandwidth to Span Ratio)SyntaxLegacy Products8560 seriesDescript
5 Legacy Command DescriptionsRC (Recall State)RC (Recall State)Syntax8560 series:8566A/B, 8568A/B:Legacy Products8560 series, 8566A/B, 8568A/BDescrip
5 Legacy Command DescriptionsRC (Recall State)See Description above.Query Data Type N/ASCPI Equivalent Commands *RCL <integer> (see "Recal
5 Legacy Command DescriptionsRCLS (Recall State)RCLS (Recall State)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionRecalls instrument st
5 Legacy Command DescriptionsREV (Revision)REV (Revision)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionReturns the firmware revision n
5 Legacy Command DescriptionsRL (Reference Level)RL (Reference Level)Syntax8560 series:8566A/B, 8568A/B:Legacy Products8560 series, 8566A/B, 8568A/BR
1 About the AnalyzerFront & Rear Panel FeaturesFront & Rear Panel FeaturesThe instrument's front and rear panel features are fully detai
5 Legacy Command DescriptionsRL (Reference Level)DescriptionSpecifies the amplitude level of the top graticule line on the display. This represents t
5 Legacy Command DescriptionsRMS (Root Mean Square Value)RMS (Root Mean Square Value)SyntaxLegacy Products8566A/B, 8568A/BDescriptionReturns the RMS
5 Legacy Command DescriptionsROFFSET (Reference Level Offset)ROFFSET (Reference Level Offset)Syntax8560 series:8566A/B, 8568A/B:Legacy Products8560 s
5 Legacy Command DescriptionsROFFSET (Reference Level Offset)UP or DN increments one vertical divisionROFFSET OAROFFSET?Query Data Type <real>
5 Legacy Command DescriptionsRQS (Request Service Conditions)RQS (Request Service Conditions)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescri
5 Legacy Command DescriptionsRQS (Request Service Conditions)Format RQS <bit number>RQS OARQS?Query Data Type The current bit mask.SCPI Equival
5 Legacy Command DescriptionsS1[one] (Continuous Sweep)S1[one] (Continuous Sweep)SyntaxLegacy Products8566A/B, 8568A/BDescriptionSets the instrument
5 Legacy Command DescriptionsS2 [two] (Single Sweep)S2 [two] (Single Sweep)SyntaxLegacy Products8566A/B, 8568A/BDescriptionSets the instrument to sin
5 Legacy Command DescriptionsSAVES (Save State)SAVES (Save State)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionSaves the current state
5 Legacy Command DescriptionsSER (Serial Number)SER (Serial Number)SyntaxLegacy Products8560 seriesDescriptionReturns the X-series instrument serial
1 About the AnalyzerDisplay AnnotationsDisplay AnnotationsDisplay Annotations are fully detailed under the chapter "Front and Rear Panel Feature
5 Legacy Command DescriptionsSETDATE (Set Date)SETDATE (Set Date)SyntaxLegacy Products8560 seriesDescriptionSets the date of the real-time clock of t
5 Legacy Command DescriptionsSETTIME (Set Time)SETTIME (Set Time)SyntaxLegacy Products8560 seriesDescriptionSets the date of the real-time clock of t
5 Legacy Command DescriptionsSMOOTH (Smooth Trace)SMOOTH (Smooth Trace)SyntaxLegacy Products8566A/B, 8568A/BDescriptionSmooths the trace according to
5 Legacy Command DescriptionsSNGLS (Single Sweep)SNGLS (Single Sweep)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionSets the instrument
5 Legacy Command DescriptionsSP (Frequency Span)SP (Frequency Span)Syntax8560 series:8566A/B, 8568A/B:464 Remote Language Compatibility Measurement A
5 Legacy Command DescriptionsSP (Frequency Span)Legacy Products8560 series, 8566A/B, 8568A/BDescriptionChanges the total displayed frequency range sy
5 Legacy Command DescriptionsSP (Frequency Span)Couplings If resolution and video bandwidths are coupled to the span width, the bandwidths changewith
5 Legacy Command DescriptionsSRQ (Service Request)SRQ (Service Request)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionSends a service r
5 Legacy Command DescriptionsSS (Center Frequency Step Size)SS (Center Frequency Step Size)Syntax8560 series:8566A/B, 8568A/B:Legacy Products8560 ser
5 Legacy Command DescriptionsSS (Center Frequency Step Size)DescriptionSpecifies the center frequency step size.Format SS <real>HZ|KHZ|MHZ|GHZ|
1 About the AnalyzerWindow Control KeysWindow Control KeysThe instrument provides three front-panel keys for controlling windows. These are:l "M
5 Legacy Command DescriptionsST (Sweep Time)ST (Sweep Time)Syntax8560 series:8566A/B, 8568A/B:Legacy Products8560 series, 8566A/B, 8568A/BDescription
5 Legacy Command DescriptionsST (Sweep Time)Format ST <real>S|MS|US|SCST UP|DNUP or DN: Increments in a 1,2,5 sequenceST AUTO|MAN (8560 series
5 Legacy Command DescriptionsSTB (Status Byte Query)STB (Status Byte Query)SyntaxLegacy Products8560 seriesDescriptionReturns to the controller the d
5 Legacy Command DescriptionsSTDEV (Standard Deviation of Trace Amplitudes)STDEV (Standard Deviation of Trace Amplitudes)SyntaxLegacy Products8566A/B
5 Legacy Command DescriptionsSUM (Sum)SUM (Sum)Syntax8560 Series:8566A/B, 8568A/B:Legacy Products8560 seriesDescriptionReturns the sum of all the tra
5 Legacy Command DescriptionsSV (Save State)SV (Save State)SyntaxLegacy Products8566A/B, 8568A/BDescriptionSaves the current state of the instrument
5 Legacy Command DescriptionsSWPCPL (Sweep Couple)SWPCPL (Sweep Couple)SyntaxLegacy Products8560 seriesDescriptionSelects either a stimulus-response
5 Legacy Command DescriptionsT1 [one] (Free Run Trigger)T1 [one] (Free Run Trigger)SyntaxLegacy Products8566A/B, 8568A/BDescriptionSets the instrumen
5 Legacy Command DescriptionsT2 [two] (Line Trigger)T2 [two] (Line Trigger)SyntaxLegacy Products8566A/B, 8568A/BDescriptionSets the instrument sweep
5 Legacy Command DescriptionsT3 [three] (External Trigger)T3 [three] (External Trigger)SyntaxLegacy Products8566A/B, 8568A/BDescriptionSets the instr
1 About the AnalyzerWindow Control KeysZoom is a toggle function. Pressing this key once increases the size of the selected window;pressing the key a
5 Legacy Command DescriptionsT4 [four] (Video Trigger)T4 [four] (Video Trigger)SyntaxLegacy Products8566A/B, 8568A/BDescriptionSets the instrument sw
5 Legacy Command DescriptionsTA (Trace A)TA (Trace A)SyntaxLegacy Products8566A/B, 8568A/BDescriptionReturns trace A amplitude values from the instru
5 Legacy Command DescriptionsTB (Trace B)TB (Trace B)SyntaxLegacy Products8566A/B, 8568A/BDescriptionReturns trace B amplitude values from the instru
5 Legacy Command DescriptionsTDF (Trace Data Format)TDF (Trace Data Format)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionFormats trace
5 Legacy Command DescriptionsTH (Threshold)TH (Threshold)Syntax8560 series:8566A/B, 8568A/B:Legacy Products8560 series, 8566A/B, 8568A/BDescriptionBl
5 Legacy Command DescriptionsTH (Threshold)Format TH <real>DM|MV|UV|DBTH UP|DNUP or DN increments by one step sizeTH ON|OFF (8560 series only)T
5 Legacy Command DescriptionsTHE (Threshold Enable)THE (Threshold Enable)SyntaxLegacy Products8566A/B, 8568A/BDescriptionTurns the threshold on or of
5 Legacy Command DescriptionsTIMEDATE (Time Date)TIMEDATE (Time Date)SyntaxLegacy Products8560 seriesDescriptionSets and returns the date and time of
5 Legacy Command DescriptionsTITLE (Title)TITLE (Title)SyntaxLegacy Products8560 seriesDescriptionActivates the screen title mode, enabling you to en
5 Legacy Command DescriptionsTM (Trigger Mode)TM (Trigger Mode)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionSelects a trigger mode: f
1 About the AnalyzerWindow Control KeysRemote Command:DISPlay:WINDow[:SELect] <number>:DISPlay:WINDow[:SELect]?Example :DISP:WIND 1Preset 1Min
5 Legacy Command DescriptionsTM (Trigger Mode)Format TM FREE|VID|LINE|EXT|TVTM?Query Data Type FREE|VID|LINE|EXT|TVSCPI EquivalentCommands:TRIGger[:S
5 Legacy Command DescriptionsTRA (Trace Data Input and Output)TRA (Trace Data Input and Output)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDesc
5 Legacy Command DescriptionsTRB (Trace Data Input and Output)TRB (Trace Data Input and Output)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDesc
5 Legacy Command DescriptionsTRC (Trace Data Input and Output)TRC (Trace Data Input and Output)SyntaxLegacy Products8566A/B, 8568A/BDescriptionTransf
5 Legacy Command DescriptionsTRDSP (Trace Display)TRDSP (Trace Display)SyntaxLegacy Products8566A/B, 8568A/BDescriptionDisplays a trace or turns it o
5 Legacy Command DescriptionsTRIGPOL (Trigger Polarity)TRIGPOL (Trigger Polarity)SyntaxLegacy Products8560 seriesDescriptionSelects the edge (positiv
5 Legacy Command DescriptionsTRSTAT (Trace State)TRSTAT (Trace State)SyntaxLegacy Products8566A/B, 8568A/BDescriptionReturns trace states to the cont
5 Legacy Command DescriptionsTS (Take Sweep)TS (Take Sweep)SyntaxLegacy Products8560 series, 8566A/B, 8568A/BDescriptionStarts and completes one full
5 Legacy Command DescriptionsVAVG (Video Average)VAVG (Video Average)Syntax8560 series:8566A/B, 8568A/B:Legacy Products8560 series, 8566A/B, 8568A/BD
5 Legacy Command DescriptionsVAVG (Video Average)Condition Legacy Spectrum Analyzers N9061A applicationAll conditions. 8566 and 8568 only - Original
Table Of ContentsT 97U 100IEEE 488.2 Common Commands 101All 101Clear Status 103Standard Event Status Enable 104Standard Event Status Register Query 10
1 About the AnalyzerMouse and Keyboard ControlMouse and Keyboard ControlIf you do not have access to the instrument front-panel, there are several wa
5 Legacy Command DescriptionsVAVG (Video Average)[:SENSe]:AVERage:COUNT <integer>(See "Average/Hold Number" on page 788)Preset 100, O
5 Legacy Command DescriptionsVB (Video Bandwidth)VB (Video Bandwidth)Syntax8560 series:8566A/B, 8568A/B:Legacy Products8560 series, 8566A/B, 8568A/BD
5 Legacy Command DescriptionsVB (Video Bandwidth)When auto coupled, the video bandwidth is calculated as ResolutionBandwidth x VideoResolution Bandw
5 Legacy Command DescriptionsVBO (Video Bandwidth Coupling Offset)VBO (Video Bandwidth Coupling Offset)SyntaxLegacy Products8566A/B, 8568A/BDescripti
5 Legacy Command DescriptionsVBR (Video Bandwidth to Resolution Bandwidth Ratio)VBR (Video Bandwidth to Resolution Bandwidth Ratio)SyntaxLegacy Produ
5 Legacy Command DescriptionsVIEW (View Trace)VIEW (View Trace)Syntax8560 series:8566A/B, 8568A/B:Legacy Products8560 series, 8566A/B, 8568A/BDescrip
5 Legacy Command DescriptionsVIEW (View Trace):TRACe[1|2|3|4|5|6:DISPlay[:STATe] ON(See "View/Blank " on page 1344)Notes The functions of V
5 Legacy Command DescriptionsVTL (Video Trigger Level)VTL (Video Trigger Level)SyntaxLegacy Products8560 seriesDescriptionSets the signal level that
5 Legacy Command DescriptionsVTL (Video Trigger Level)Preset 0 dBmNotes Setting a value for VTL sets the trigger mode to VIDEO, even if it was not al
5 Legacy Command DescriptionsXCH (Exchange)XCH (Exchange)SyntaxLegacy Products8566A/B, 8568A/BDescriptionExchanges the contents of the source and des
1 About the AnalyzerMouse and Keyboard ControlThis method can be used to access any of the front-panel keys by using a mouse; as for example ifyou ar
5 Legacy Command DescriptionsXCH (Exchange)510 Remote Language Compatibility Measurement Application Reference
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceThe Swept SA measurement uses both swept and FFT analysis,and the frequency and time domain
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeasurement Commands and their Results for Swept SAThe INITiate and CONFigure syntax, as w
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceCommand n Return Valuemeasurements that have already been combined, in theaveraging calcul
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceCommand n Return Value2 Returns Trace 2 data as a series of x,y pairs3 Returns Trace 3 dat
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceSwept SA Measurement Descriptionl Swept Spectrum Analysis (Freq Domain): The analyzer swee
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y ScaleAMPTD Y ScaleThe Amplitude front-panel key activates the Amplitude menu and s
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y Scale+23dBm + RL Offset – External Gain (for EXA and CXA)This maximum value is de
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y Scaleconfiguration uses a single attenuator with combined mechanical and electroni
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y Scale(note that Configuration 2 is not strictly speaking a dual-section attenuator
1 About the AnalyzerMouse and Keyboard ControlPC KeyboardIf you have a PC keyboard plugged into the instrument (or via Remote Desktop), certain key c
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y Scale[:SENSe]:POWer[:RF]:ATTenuation?[:SENSe]:POWer[:RF]:ATTenuation:AUTO OFF|ON|0
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y Scalebe increased with the knob and step keys, but not decreased.Max CXA N9000A–50
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y Scaleand are negligible for front panel use. See "Using the Electronic Atten
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y ScaleMore InformationMechanical Attenuator Transition RulesWhen the Electronic Att
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y ScaleThe “finer steps” advantage of the electronic attenuator is beneficial in opt
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y ScaleMax Dual attenuator configuration: 24dBSingle attenuator configuration: th
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y ScaleCOMBined[:SENSe]:POWer[:RF]:RANGe:OPTimize:ATTenuation?Notes The SCPI paramet
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y ScaleExample :POW:RANGe:OPT:ATT OFFInitial S/W Revision Prior to A.02.00Elec Atten
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y ScaleExample POW:ATT:STEP 2Notes Note this feature works like a 1-N choice from th
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y ScaleScale / DivSets the units per vertical graticule division on the display. Thi
1 About the AnalyzerMouse and Keyboard ControlFront-panel key Key codeSingle CTRL+ALT+SCont CTRL+ALT+CZoom CTRL+SHIFT+ZNext Window CTRL+SHIFT+NSplit
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y ScaleDependencies If Normalize is on, Scale Type forced to Log and is grayed out.C
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y ScaleCouplings The active marker position determines where the centering will be a
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y ScaleKey PathAMPTD Y ScaleScope Meas GlobalRemote Command[:SENSe]:POWer[:RF]:PADJu
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y ScaleY Axis UnitDisplays the menu keys that enable you to change the vertical (Y)
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y Scaletrace 1 is on the fifth graticule line from the top, it represents 5 dBm and
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y ScaledBmVSets the amplitude unit for the selected amplitude scale (log/lin) to dBm
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y ScaleVSets the amplitude unit for the selected amplitude scale (log/lin) to volt.K
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y ScaledBµASets the amplitude unit for the selected amplitude scale (log/lin) to dBµ
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y ScaleKey PathAMPTD Y Scale, Y Axis UnitDependencies Grayed out if no Amplitude Cor
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y ScaleDependencies Grayed out if no Amplitude Correction with an Antenna Unit is on
1 About the AnalyzerMouse and Keyboard ControlFront-panel key Key code1 12 23 34 45 56 67 78 89 90 0This is a pictorial view of the table:54 Remote L
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y ScaleExample UNIT:POW DBUAMDependencies Grayed out if no Amplitude Correction with
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y ScaleMore InformationOffsets are used when gain or loss occurs between a device un
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y ScaleSelecting the Low Noise Path Enable option provides a lower noise floor, espe
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y ScaleStandard PathThis path gives the best remote-control throughput, minimizes ac
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y ScaleRemote Command[:SENSe]:POWer[:RF]:MW:PRESelector[:STATe] ON|OFF|0|1[:SENSe]:P
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y Scalethe key is not shown.If a POW:GAIN:BAND FULL command is sent when a low band
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAMPTD Y ScaleKey PathAMPTD Y Scale, Internal PreampExample :POW:GAIN ON:POW:GAIN:BAND FULL
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAuto CoupleAuto CoupleThe Auto Couple feature provides a quick and convenient way to autom
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceAuto CoupleAuto/Man 1-of-N keysAn Auto/Man 1-of-N key allows you to manually pick from a l
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceBWBWThe BW key opens the bandwidth menu, which contains keys to control the ResolutionBand
1 About the AnalyzerInstrument Security & Memory VolatilityInstrument Security & Memory VolatilityIf you are using the instrument in a secure
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceBWExample BAND 1 KHZBAND?BWID:AUTO ONBWID:AUTO?Notes For numeric entries, all RBW Types ch
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceBWMore InformationWhen the Res BW is manually selected, it may be returned to the coupled
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceBWAn * is displayed next to the VBW annotation when certain detector types (Average, EMI A
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceBWMax 50 MHzDefault Unit HzBackwards CompatibilityNotesFor backwards compatibility this co
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceBWExample BAND:VID:RAT 2BAND:VID:RAT?BAND:VID:RAT:AUTO 0BAND:VID:RAT:AUTO?Notes The values
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceBW1. If the detector is Peak and the EMC Standard is set to either CISPR or MIL, use 10.0
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceBW[:SENSe]:FREQuency:SPAN:BANDwidth[:RESolution]:RATio:AUTO?Example FREQ:SPAN:BAND:RAT 200
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceBWFilter TypeBesides the familiar Gaussian filter shape, there are certain special filter
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceBWWhen the Flattop filter type is chosen, a new set of 134 RBW hardware settings are avail
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceBWRemote Command[:SENSe]:BANDwidth|BWIDth:TYPE DB3|DB6|IMPulse|NOISe[:SENSe]:BANDwidth|BWI
1 About the AnalyzerInstrument Security & Memory Volatility56 Remote Language Compatibility Measurement Application Reference
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceBWThe Filter Type menu lets you choose the filter bandwidth (–3 dB, –6 dB, Noise or Impuls
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceBWKey PathBW, RBW Control, Filter BWExample BAND:TYPE DB3Readback –3 dBInitial S/W Revisio
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceBW562 Remote Language Compatibility Measurement Application Reference
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceCont (Continuous Measurement/Sweep)Cont (Continuous Measurement/Sweep)Sets the analyzer fo
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceCont (Continuous Measurement/Sweep)number k stops incrementing. A measurement average usua
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceFileFileOpens a menu that enables you to access various standard and custom Windows functi
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceFileOr use Alt-Tab: press and hold the Alt key and press and release the Tab key until th
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceFileParameter Name Print ThemesParameter Type EnumMode AllRemote Command:SYSTem:PRINt:THEM
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceFileRestore DownThis key allows you to Restore Down the Instrument Application and reverse
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceFileKey PathFileMode AllNotesThe Instrument Application willclose. No further SCPI command
2 About the N9061A MeasurementApplicationThis chapter provides general information about the N9061Aapplication. It includes the following topics:l &qu
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceFREQ ChannelFREQ ChannelAccesses a menu of keys that allow you to control the Frequency an
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceFREQ ChannelState Saved Saved in instrument stateMin Hardware dependent; Zone Span depende
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceFREQ ChannelPreset 13.255 GHzState Saved Saved in instrument stateMin Start Frequency of t
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceFREQ ChannelCenter FreqSets the frequency that corresponds to the horizontal center of the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceFREQ ChannelPreset and Max values are dependent on Hardware Options (5xx)If no terminator
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceFREQ Channel503(N9000A)1.505 GHz 3.0 GHz 3.08 GHz507(all but N9000A)3.505 GHz 7.0GHz 7.1
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceFREQ ChannelOption when turn TGon and can’ttune belowwhile TG on)clipped to thisFreq when
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceFREQ Channelis independent in each mode and common across all the measurements in the mode
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceFREQ Channelcome back to the band you were in with the Center Frequency that you had. How
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceFREQ ChannelPreset 0 HzState Saved Saved in instrument state.Min –40.049995 MHzMax 40.0499
2 About the N9061A Measurement ApplicationN9061A Application DescriptionN9061A Application DescriptionN9061A is a Remote Language Compatibility appli
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceFREQ Channelsettings of Source Numerator, Source Denominator and Power Sweep.Couplings In
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceFREQ ChannelDefault Unit HzStatus Bits/OPCdependenciesNon-overlappedInitial S/W Revision P
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceFREQ Channelsettings of Source Numerator, Source Denominator and Power Sweep.Couplings In
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceFREQ Channelthe current mixer setup. It can be queried with the SCPI command :FREQ:STOP? M
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceFREQ ChannelDependencies Span, RBW, Center frequencyIf the electronic/soft attenuator is e
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceFREQ ChannelScope Meas GlobalRemote Command[:SENSe]:FREQuency:OFFSet <freq>[:SENSe]:
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceFREQ Channeloffset, even on a trace that is not updating will immediately change all of th
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputInput/OutputThe Input/Output features are common across multiple Modes and Mea
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/Outputcurrently selected input.BackwardsCompatibility SCPI[:SENSe]:FEED IQ|IONLy|QO
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/Output2. When INPut:MIXer INTernal is received, SENSe:FEED RF is executed.3. When IN
2 About the N9061A Measurement ApplicationDocumentation for the N9061A applicationDocumentation for the N9061A applicationScope of this DocumentThis
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputYY is AC or DCZZ is 50Ω or 75ΩInitial S/W Revision Prior to A.02.00Input Z Cor
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputRF CouplingSpecifies alternating current (AC) or direct current (DC) coupling
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputOn models that are always DC coupled, such as millimeter wave models (frequenc
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputThe Agilent 113x Series active probes can be used for both single ended and di
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/Outputcalibrated together. The probe calibration is done for a specific channel (I o
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputThe [:SENSe]:FEED RF|IQ|IONLy|QONLy|AREFerence|IFALign command supports all pa
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputI/Q PathSelects which I/Q input channels are active. The LED next to each I/Q
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputNotes For R&S FSQ-B71 compatibilityPreset IQInitial S/W Revision Prior to
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputI SetupAccess the channel setup parameters for the I channel.Key PathInput/Out
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputRemote Command:INPut[1]:IQ:BALanced[:STATe] OFF|ON|0|1:INPut[1]:IQ:BALanced[:S
Table Of ContentsLegacy Products 210Description 210A3 [three] (View Mode for Trace A) 211Syntax 211Legacy Products 211Description 211A4 [four] (Blank
2 About the N9061A Measurement ApplicationGeneral Rules and LimitationsGeneral Rules and LimitationsThe N9061A application has been designed to emula
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputI SkewSets the skew factor for the I channel. The skew will shift the channel
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputRemote Command[:SENSe]:CORRection:IQ:I|Q:ATTenuation:RATio <real>[:SENSe
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputKey PathInput/Output, I/Q, I Setup | Q Setup, I Probe | Q Probe, CouplingReadb
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/Output:INP:IQ:DIFF OFF:INP:IQ:IMP 50Notes Provided for E4406A code compatibility.The
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/Outputbe identical. This does not apply to Probe settings or to parameters that are
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/Output159;Settings Alert;I/Q mismatch:Differential.Couplings Some active probes incl
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputThis is unaffected by Preset but is set to the default value on a "Restor
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputAttenuationThe attenuation is part of the calibration data stored with the pro
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputCalibrateInvokes the guided probe calibration. The guided probe calibration is
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/Outputstate. When Differential Input is on, both the data for the probe attached to
2 About the N9061A Measurement ApplicationGeneral Rules and LimitationsCouplingsFor optimal use of the X-Series instrument, N9061A uses the auto coup
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputThe guided calibration (front panel only) will show connection diagrams and gu
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/Outputcommand.State Saved No.Initial S/W Revision Prior to A.02.00ExitExits the cali
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/Outputstatus. The calibration data is stored permanently (survives a power cycle) an
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/Output[:SENSe]:CORRection:IQ:I|Q:ATTenuation?Example Set the attenuation for the cur
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputCouplingSome probe types allow coupling to reject low frequencies. This will f
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputLFR2Turns on low frequency rejection, rejecting signal component lower than 0.
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputKey PathInput/Output, I/Q, I Setup | Q Setup, I Probe | Q ProbeRemote Command:
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputRemote Command[:SENSe]:FEED:AREFerence REF50|REF4800|OFF[:SENSe]:FEED:AREFeren
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputKey PathInput/Output, RF CalibratorExample :FEED:AREF REF50Readback 50MHzInit
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputEntering an External Gain value does not affect the Reference Level, therefore
2 About the N9061A Measurement ApplicationGeneral Rules and Limitationsconcept, except that the value to be passed as a parameter to the next command
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputKey PathInput/Output, External GainRemote Command[:SENSe]:CORRection:SA[:RF]:G
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputState Saved Saved in instrument state.Min –100dBMax 100dBReadback MS, <Ex
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputThis key is grayed out in modes that do not support BTS.Preset This is unaffec
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputExample Set the I Ext Gain to 10 dBCORR:IQ:I:GAIN 10Set the I Ext Gain to –10
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputRestore Input/Output DefaultsThis selection causes the group of settings and d
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputKey PathInput/Output, CorrectionsMode SA, DVB-T/H, DTMB, SEQAN, TDSCDMADepende
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputSelect CorrectionSpecifies the selected correction. The term "selected co
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputSelect CorrectionSpecifies the selected correction. The term "selected co
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputExample SENS:CORR:CSET1 ONDependencies Turning this on automatically turns on
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputSelect CorrectionSpecifies the selected correction. The term "selected co
2 About the N9061A Measurement ApplicationGeneral Rules and LimitationsDevice Clear is supported by N9061A, and causes a mode preset of the instrumen
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputSelect CorrectionSpecifies the selected correction. The term "selected co
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputAntenna UnitFor devices (like antennas) that make measurements of field streng
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputdBµV/mSets the antenna unit todBµV/m. If this correction is turned on, and Ap
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputExample :CORR:CSET:ANT GAUSReadback "dBG"Initial S/W Revision A.02.
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputTo effect this correction, the goal, for any particular start and stop frequen
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputIf we interpolate on a linear scale, we assume that the two points are connect
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputExample :CORR:CSET1:COMM "this is a comment"Notes 60 chars max; may
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputCorrections arrays are not affected by a Preset, because they are in the Input
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputDelete All CorrectionsErases all correction values for all 4 Amplitude Correct
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputThe values sent in the command will totally replace all existing correction po
2 About the N9061A Measurement ApplicationHardware and Firmware Requirements for N9061AHardware and Firmware Requirements for N9061AFor maximum compa
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputIf an external frequency reference is being used, you must enter the frequency
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputSenseThe external reference is used if a valid signal is sensed at the Ext Ref
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputFor the instrument to stay locked, the value entered must be within 5 ppm of t
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/Output(60 Hz), to take advantage of that superior performance. When using an externa
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/Output--:INIT:CONT OFF:INIT:IMM;*WAI?--:INIT:CONT OFF:READ?--:INIT:CONT OFF:MEASure?
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputKey PathInput/Output, Freq Ref InMode AllRemote Command[:SENSe]:ROSCillator:CO
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/Output:READ?--:INIT:CONT OFF:MEASure?When the acquisition ceases, in addition to the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputState Saved Not saved in instrument stateReadback Normal|Stop AcqInitial S/W R
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputWhen the acquisition ceases, in addition to the error condition(s) described a
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputOutput ConfigAccesses keys that configure various output settings, like the fr
2 About the N9061A Measurement ApplicationHardware and Firmware Requirements for N9061AProduct Name Instrument Model Number Upper Frequency Limit Fir
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputPolaritySets the output to the Trig 1 Out or Trig 2 Out connector to trigger o
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputMeasuringSelects the Measuring trigger signal to be output to the Trig 1 Out o
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputExample TRIG1:OUTP GATEReadback GateInitial S/W Revision Prior to A.02.00Odd/E
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputState Saved Saved in instrument stateInitial S/W Revision Prior to A.02.00Pola
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputExample TRIG1:OUTP HSWPReadback SweepingInitial S/W Revision Prior to A.02.00M
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputGateSelects the gate signal to be output to the Trig 1 Out or Trig 2 Out conne
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputState Saved Saved in Input/Output StateReadback line 1-of-N selection [variabl
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputOUTPut:ANALog:AUTO?Example OUTP:ANAL:AUTO ONPreset ONState Saved Saved in Inpu
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/Outputretrace, as the analyzer remains tuned to the Center Frequency and does not sw
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputDependencies Because the Log Video output uses one of the two IF processing ch
2 About the N9061A Measurement ApplicationInstalling the N9061A ApplicationInstalling the N9061A ApplicationN9061A is a licensed application for X-Se
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/Outputretrace (after a sweep and before the next sweep starts).This function depends
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputDigital BusThis menu allows you to configure the LVDS connector located on the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputKey PathInput/Output, Output ConfigRemote Command:OUTPut:IQ:OUTPut IQ1|IQ250|O
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputKey PathInput/Output, Output Config, I/Q Cal OutReadback OffInitial S/W Revisi
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/Outputcauses the aux output type to be offReadback Text OffInitial S/W Revision A.04
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/Outputat the bottom of the bandwidth will “fold”. For example, with a 40 MHz bandw
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceInput/OutputKey PathInput/Output, Output Config, Aux IF OutExample OUTP:AUX LOGVideocauses
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerMarkerThe Marker key accesses the Marker menu. A marker can be placed on a trace to
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerPreset OFF (all markers)State Saved The marker control mode is saved in instrument s
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerNotes If no suffix is sent it will use the fundamental units for the current marker
2 About the N9061A Measurement ApplicationInstalling the N9061A ApplicationlOnline assistance: http://www.agilent.com/find/assistlIf you do not have
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerThe entered value in Trace Points is immediately translated into the current X Axis
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker:CALCulate:MARKer[1]|2|...12:Y?Example CALC:MARK2:MODE POS turns on marker 2 as a no
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerSetting or Querying the Marker Z PositionThe command below sets the Marker Z positio
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkeroffscreen they always returned a valid result. In the X-Series, markers which are o
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerSelect MarkerSpecifies the selected marker. The term “selected marker” is used throu
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerSelect MarkerSpecifies the selected marker. The term “selected marker” is used throu
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerSelect MarkerSpecifies the selected marker. The term “selected marker” is used throu
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerSelect MarkerSpecifies the selected marker. The term “selected marker” is used throu
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerRemote Command:CALCulate:MARKer[1]|2|...12:STATe OFF|ON|0|1:CALCulate:MARKer[1]|2|..
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker• If a Marker Function is on, the X Axis value and the Y-axis function result the ma
2 About the N9061A Measurement ApplicationSetting up N9061ASetting up N9061ATo set up your X-Series instrument for emulation of one of the supported
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerFixed Marker Z Axis ValueThe Marker Z position determines which of the 301 traces (0
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerFixed Marker X Axis ValueKey PathMarker, FixedExample :CALC:MARK:MODE FIX sets Marke
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerposition, will not move off screen in the Spectrogram Window if the storage size is
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerExample :CALC:MARK:MODE FIX sets Marker 1 to Fixed.Notes See the description under t
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerIf Spectrogram is on, the marker result block has a third line displaying the time v
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerPropertiesOpens a menu used to set certain properties of the selected marker.Key Pat
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerKey PathMarkerNotes The selected marker is remembered even when not in the Marker me
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerKey PathMarkerNotes The selected marker is remembered even when not in the Marker me
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerKey PathMarkerNotes The selected marker is remembered even when not in the Marker me
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerKey PathMarkerNotes The selected marker is remembered even when not in the Marker me
2 About the N9061A Measurement ApplicationHints and TipsHints and TipsThis section provides hints and tips that will help you get the most from the X
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerRange (for SCPI command): 1 to 12. If the range is exceeded the value is clipped.Cou
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerPreset Marker 1State Saved The number of the selected marker is saved in instrument
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerPreset Marker 1State Saved The number of the selected marker is saved in instrument
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerPreset Marker 1State Saved The number of the selected marker is saved in instrument
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerPreset Marker 1State Saved The number of the selected marker is saved in instrument
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerState Saved Saved in instrument stateBackwards CompatibilityNotesThe X Axis Scale of
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerFrequencySets the marker X Axis scale to Frequency, displaying the absolute frequenc
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerauto setting for time domain traces. In a delta-marker mode it is the (sweep) time i
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerSee "Auto Init OFF" on page 699.Key PathMarker, PropertiesRemote Command:C
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerThis flowchart makes it clear that putting all lower-numbered traces in View is the
Table Of ContentsDescription 219ACPLOWER (Lower Adjacent Channel Power) 220Syntax 220Legacy Products 220Description 220ACPMAX (Maximum Adjacent Channe
2 About the N9061A Measurement ApplicationHints and TipsChanging ModesAfter changing into or out of N9061A mode, allow at least a 1 second delay befo
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerIf Auto Init is set to On for a marker and that marker is on, that marker’s Marker T
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerMin 1Max 6Readback line [TraceN, Auto Init] or [TraceN, Manual] where N is the trace
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerThis flowchart makes it clear that putting all lower-numbered traces in View is the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerIf Auto Init is set to On for a marker and that marker is on, that marker’s Marker T
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerMin 1Max 6Readback line [TraceN, Auto Init] or [TraceN, Manual] where N is the trace
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerThis flowchart makes it clear that putting all lower-numbered traces in View is the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerIf Auto Init is set to On for a marker and that marker is on, that marker’s Marker T
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerMin 1Max 6Readback line [TraceN, Auto Init] or [TraceN, Manual] where N is the trace
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerThis flowchart makes it clear that putting all lower-numbered traces in View is the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerIf Auto Init is set to On for a marker and that marker is on, that marker’s Marker T
2 About the N9061A Measurement ApplicationService and CalibrationService and CalibrationSince the Performance Verification and Adjustment Software us
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerMin 1Max 6Readback line [TraceN, Auto Init] or [TraceN, Manual] where N is the trace
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerThis flowchart makes it clear that putting all lower-numbered traces in View is the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerIf Auto Init is set to On for a marker and that marker is on, that marker’s Marker T
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerMin 1Max 6Readback line [TraceN, Auto Init] or [TraceN, Manual] where N is the trace
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerThis flowchart makes it clear that putting all lower-numbered traces in View is the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerIf Auto Init is set to On for a marker and that marker is on, that marker’s Marker T
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerMin 1Max 6Readback line [TraceN, Auto Init] or [TraceN, Manual] where N is the trace
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerThis flowchart makes it clear that putting all lower-numbered traces in View is the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerIf Auto Init is set to On for a marker and that marker is on, that marker’s Marker T
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerMin 1Max 6Readback line [TraceN, Auto Init] or [TraceN, Manual] where N is the trace
2 About the N9061A Measurement ApplicationService and Calibration72 Remote Language Compatibility Measurement Application Reference
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerThis flowchart makes it clear that putting all lower-numbered traces in View is the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerIf Auto Init is set to On for a marker and that marker is on, that marker’s Marker T
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerthe Y-axis result. Additional information is shown for markers which have marker fun
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerNotes Fixed markers are not counted, but a Fixed marker will have a count stored in
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkercount query. Note this result may simply mean that the first sweep after the counter
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker5. If the reference marker is not a fixed marker, the display shows the difference b
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerGate TimeControls the length of time during which the frequency counter measures the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker:CALCulate:MARKer[1]|2|3|4:FCOunt:RESolution:AUTO OFF|ON|0|1 isaccepted and ignored:
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarkerCouplings Sets the selected marker to 1.Preset n/a.Initial S/W Revision Prior to A.0
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionMarker FunctionThe Marker Function key opens up a menu of softkeys that all
3 Programming the AnalyzerThis section provides introductory information about theprogramming documentation included with your product.l"What Pro
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionMore InformationThe units to be used for displaying Marker Function results
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker Functionmeasures the average power across some time interval in zero span.Interval
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker Function.In the X-Series the marker itself has a width attribute, which you set us
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionNote that all of the alias commands described below cause the specified mar
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker Function:CALCulate:MARKer[1]|2|3|4:X:STARt?:CALCulate:MARKer[1]|2|3|4:X:STOP
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker Functionnever offscreen. Users who depended on this clipping behavior by setting B
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionThe value in Trace Points is translated into the current X Axis Scale units
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionKey PathMarkerNotes The selected marker is remembered even when not in the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionKey PathMarkerNotes The selected marker is remembered even when not in the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionKey PathMarkerNotes The selected marker is remembered even when not in the
3 Programming the AnalyzerWhat Programming Information is Available?What Programming Information is Available?The X-Series Documentation can be acces
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionKey PathMarkerNotes The selected marker is remembered even when not in the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionCALC:MARK:Y? returns the y-axis value of the Marker Noise function for mark
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionWhen Band/Interval Power is selected while in the Marker Function Off state
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionCALC:MARK:FUNC? returns the current setting of band function for the marker
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionOn time domain traces, interval density is the average power in the interva
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionIt is legal to change the width of the band even if there is no marker func
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionRemote Command:CALCulate:MARKer[1]|2|...4:X:POSition:SPAN <param>:CAL
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionThe unit of the parameter must match the current domain of the trace the se
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker Function(buckets) by translating back based on the current X Axis Scale settings at
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionPreset If 0, Band/Interval Span is set to 5% of span, when a marker functio
3 Programming the AnalyzerWhat Programming Information is Available?Resource DescriptionAgilent VISAUser's GuideDescribes the Agilent Virtual In
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker Function• If in Auto, then whenever the Span changes, the Band Span for Marker Nois
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionMeasure at MarkerThis key and all the keys in this menu only appear with th
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionDependencies If BW & Avg Type is in an Autocoupled state, the (up to th
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionName DetectorNormal NormalPeak PeakSample SampleNeg Peak Negative PeakRMS A
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker Function• Each detector is then read in successive single-point zero span sweeps, u
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionPreset OffState Saved Saved in instrument stateReadback Text On|OffInitial
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionIf the Measure at Marker window is being displayed, and one of the detector
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionSets the detector for measure at marker detector 1 to OffPreset PeakState S
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionReadback Text Detector nameInitial S/W Revision A.02.00Detector 1This menu
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionDetector 1This menu lets you select the detector to be used for Detector 1,
3 Programming the AnalyzerList of Supported SCPI CommandsList of Supported SCPI CommandsWhen the N9061A application has been selected, the X-Series i
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionKey PathMarker Function, Measure at Marker, DetectorsRemote Command See &qu
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionSets the detector for measure at marker detector 1 to Quasi peak:CALC:MAM:D
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionExample :CALC:MAM:DET2 QPESets the detector for measure at marker detector
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionDetector 2This menu lets you select the detector to be used for Detector 2,
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionDetector 2This menu lets you select the detector to be used for Detector 2,
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker Functionas a parameter, sets detector 2 to Quasi Peak. If sent with Off as a parame
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionPreset Quasi PeakState Saved Saved in instrument stateReadback Text Detecto
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionExample :CALC:MAM:DET3 QPESets the detector for measure at marker detector
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionDetector 3This menu lets you select the detector to be used for Detector 3,
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionDetector 3This menu lets you select the detector to be used for Detector 3,
3 Programming the AnalyzerList of Supported SCPI CommandsC:CALCulate:BWIDth|BANDwidth:NDB "N dB Points " on page 829:CALCulate:BWIDth|BANDw
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker Functionas a parameter, sets detector 3 to EMI Average. If sent with Off as a para
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionPreset EMI AverageState Saved Saved in instrument stateReadback Text Detect
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionExample :CALC:MAM:DET3 QPESets the detector for measure at marker detector
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionKey PathMarker Function, Measure at Marker, DetectorsRemote Command See &qu
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker Functionand Average Type are currently in Auto. If set to “As Set”, then the curre
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionIf set to “Autocoupled”, then the RBW and Average Type are selected by the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionIf set to “Autocoupled”, then the RBW and Average Type are selected by the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker FunctionCenter Presel On/OffThis key controls the automatic centering of the presel
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker ToMarker ToThe Marker -> key accesses menu keys that can copy the current marker
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker ToMkr->CF StepSets the center frequency (CF) step size of the analyzer to the ma
3 Programming the AnalyzerList of Supported SCPI Commands:CALCulate:LLINe{1:6}:COPY "Copy from Limit" on page 814:CALCulate:LLINe{1:6}:DATA
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker ToMkr->StopChanges the stop frequency to the frequency of the selected marker. T
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker Toassign that value to the reference level (in dBm). PSA would just assign the delt
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker ToRemote Command:CALCulate:MARKer[1]|2|...12[:SET]:ZSPan:CENTerExample :CALC:MARK2:
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMarker ToNotes Sending this command selects the subopcoded markerDependencies This functio
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeasMeasPressing the Meas key displays a menu of measurements that are available in the cu
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeasThe INITiate command works in a slightly different fashion in the Spectrogram view. I
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeasCommand n Return Value13. Marker 3 value (x,y)14. Marker 4 value (x,y)15. Marker 5 val
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeasSwept SA Measurement Descriptionl Swept Spectrum Analysis (Freq Domain): The analyzer
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupMeas SetupThe Meas Setup key opens a menu of softkeys that allow you to control
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupMore InformationWhen in Single, the sweep stops when N is reached. You can add m
3 Programming the AnalyzerList of Supported SCPI Commands{1:12}:FUNCtion:BAND:RIGHt:CALCulate:MARKer{1:12}:FUNCtion:BAND:SPAN"Band/Interval Span
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupKey PathMeas SetupRemote Command[:SENSe]:AVERage:TYPE:AUTO OFF|ON|0|1[:SENSe]:AV
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas Setup1. Trace averaging (see “"Trace/Detector" on page 1321”) averages sig
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupThe equation for trace averaging on the log-pwr scale is shown below, where K is
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupVoltage AvgIn this Average type, all filtering and averaging processes work on t
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupKey PathMeas Setup, LimitsNotes The selected limit is remembered even when not i
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupNotes The selected limit is remembered even when not in the Limit Menu.Preset Li
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupPreset Limit 1, not affected by Mode Preset, preset by Restore Mode Defaults.Sta
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas Setup:CALCulate:LLINe[1]|2|...6:DISPlay?Example :CALC:LLIN2:DISP ON turns on the disp
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupSelect LimitSpecifies the selected limit. The term “selected limit” is used thro
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupKey PathMeas Setup, Limits, PropertiesNotes The selected limit is remembered eve
Table Of ContentsADJALL (LO and IF Adjustments) 231Syntax 231Legacy Products 231Description 231AMB (A minus B into A) 232Syntax 232Legacy Products 232
3 Programming the AnalyzerList of Supported SCPI Commands:CALCulate:MARKer{1:12}[:SET]:STEP "Mkr->CF Step" on page 779:CALCulate:MARKer{
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupA trace can have multiple limit lines simultaneously; in that case, only one upp
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupPreset Limits 1 and 2 preset to 1, Limits 3 and 4 preset to 2, Limits 5 and 6 pr
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupTest TraceSelects the trace you want the limit to test. A limit is applied to on
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupExample :CALC:LLIN3:TRAC 2 applies limit 3 to trace 2.Notes When the trace displ
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupTest TraceSelects the trace you want the limit to test. A limit is applied to on
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupPreset Upper for Line 1, 3, and 5; Lower for Line 2, 4, 6.Not affected by Mode P
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupFor log amplitude interpolation and log frequency interpolation, the interpolati
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupFixed / RelativeOpens a menu which will allow you to specify that the selected l
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupState Saved Saved in instrument state.Initial S/W Revision A.02.00Relative to RL
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupExample :CALC:LLIN:DESC “European Emissions”Dependencies 60 characters maxPreset
3 Programming the AnalyzerList of Supported SCPI Commands:CALibration:DATA:BACKup "Perform Backup (Remote Command Only)" on page 1289:CALib
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupWhen the Margin is selected, it may be turned off by pressing the Margin key unt
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupThe table editor will only operate properly if the analyzer is sweeping, because
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupAmplitudeLets you edit the Amplitude of the current row.Key PathMeas Setup, Limi
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupCopy from LimitCopies an existing limit into the current limit, including all se
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupCopy from LimitCopies an existing limit into the current limit, including all se
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupBuild from TraceBuilds a limit using an existing trace. This command will overwr
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupExample :CALC:LLIN2:BUIL TRACE1 builds limit line 2 based on the data in trace 1
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupNote that an upper limit will be built above the trace, while a lower limit will
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas Setuptraces (Description, Associated Trace, Type, Margin, Interpolation, Relative to
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupOffsetEnters a menu which allows you to offset the limit trace by a specified fr
3 Programming the AnalyzerList of Supported SCPI Commands:CALibration:TEMPerature:LALL? "Show Alignment Statistics" on page 1274:CALibratio
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupExample :CALC:LLIN:OFFS:Y –3 dB sets the Y axis offset to –3 dB.:CALC:LLIN:OFFSe
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupIf the domain of the selected limit does not match the domain of the X Axis, no
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupIf the trace is at or within the bounds of all applicable limits, but outside th
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupChanging the X Axis Unit will erase all your limit lines. Are you sure you want
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas Setup<ampl>Amplitude values units default to dBm. Up to two amplitude values ca
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupLimit Line Fail? (Remote Command Only)Tests a limit line against its associated
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupRemote Command:CALCulate:LIMit[1]|2|...6:CONTrol:POINts?Example :CALC:LIM:CONT:P
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupRemote Command:CALCulate:LIMit[1]|2|...6:UPPer:POINts?Example :CALC:LIM:UPP:POIN
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupExample :CALC:LIM:FAIL?returns a zero if limit line 1’s associated trace has no
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas Setup:CALCulate:LLINe:CMODe?Example :CALC:LLIN:CMOD RELmakes all limit lines relative
3 Programming the AnalyzerList of Supported SCPI Commands:DISPlay:MENU[:STATe] "Full Screen" on page 1463:DISPlay:THEMe "Theme" o
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupPreset Off, –3.01 dBOFFState Saved The on/off status and the offset value are bo
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas Setupskirts. There is one pixel between the arrow and the trace.N dB Points can be us
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas Setup832 Remote Language Compatibility Measurement Application Reference
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupPhNoise OptSelects the LO (local oscillator) phase noise behavior for various de
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas Setup• "All other Models" on page 835Key PathMeas Setup, PhNoise OptRemote
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupSpan > 22 MHz, or whenRBW > 400 kHz, or whenCF ≤ 12 MHz and Span < 495
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupOtherwise, Auto will choose Best Wide-offset Phase NoiseNote that in these model
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas Setupof measurements (especially remote measurements where the center frequency is ch
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupPXA with option EP1: [single loop]Models with option EP2: [medium loop bandwidth
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas Setupparameter is honored and the HIGH state set, and returned to a query, but the Me
3 Programming the AnalyzerList of Supported SCPI CommandsI:ID? Also a legacy command. See "ID (Identify)" on page 314.:INITiate:CONTinuous
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupHigh (Best Log Accy)When ADC dither is set to High, the scale fidelity is especi
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas Setupanalyzer, the dynamic range is always better with it on than off. The Swept IF G
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupExample IF:GAIN:SWEP:AUTO ONPreset ONInitial S/W Revision Prior to A.02.00Low Ga
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas Setupthe range to either the high or low gain setting. But you must know that your me
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupAutorange (Slower – Follows Signals)Turns the ADC ranging to automatic which pro
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupAnalog Demod Tune & ListenThe Analog Demod Tune & Listen key opens the A
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupState Saved Saved in instrument state.BackwardsCompatibility SCPI[:SENSe]:DEMod:
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupFMPressing this key, when it is not selected, selects and activates the FM demod
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupDe-emphasis (FM Demod only)The De-emphasis setting controls a single-pole filter
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupDe-emphasis (FM Demod only)The De-emphasis setting controls a single-pole filter
3 Programming the AnalyzerList of Supported SCPI Commands:INSTrument[:SELect]:INSTrument[:SELect]?"Mode" on page 860Specify parameter RLC t
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupDe-emphasis (FM Demod only)The De-emphasis setting controls a single-pole filter
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupΦMPressing this key, when it is not selected, selects and activates the ΦM demod
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupOffPressing this key, turns the demodulation function off.Key PathMeas Setup, An
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupDemod State (Remote Command Only)Sets or queries the state of the Analog Demod
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupMore InformationThere are 2 types of noise sources: a Smart Noise Source (SNS),
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupExample SOUR:NOIS:TYPE NORMCouplings If no SNS is connected, this parameter will
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas Setup• Set the Detector to AVERAGE• Set the sweep time to 16ms - sets the variance co
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas Setupdata is issued in printed form when an SNS is purchased or can be read from the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupMore InformationThere are 2 types of noise sources: a Smart Noise Source (SNS),
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMeas SetupCouplings If an SNS is connected, and the Type is set to SNS, this parameter tur
3 Programming the AnalyzerList of Supported SCPI Commands:MMEMory:STORe:TRACe "Trace (+State)" on page 1036:MMEMory:STORe:TRACe:DATA "
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceModeModeThe Mode key allows you to select the available Measurement Applications or “Modes
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceModefollowing::INST:SEL EMI:CONF FSCThis results in the instrument being placed in the EMI
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceModeremains allocated even when it is not running, and is not released until the analyzer
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceModeIf you are using the Help feature, this mode must be currently active to access its de
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceModeINST:NSEL 8Initial S/W Revision Prior to A.02.00W-CDMA with HSPA+Selects the W-CDMA wi
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceModeIf you are using the Help feature, this mode must be currently active to access its de
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceModePhase NoiseThe Phase Noise mode provides pre-configured measurements for making genera
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceModeExample INST:SEL ADEMODINST:NSEL 234Initial S/W Revision Prior to A.02.00TD-SCDMA with
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceModeIf you are using the Help feature, this mode must be currently active to access its de
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceModeDVB-T/H with T2Selects the DVB-T/H mode for measurements of digital video signals usin
3 Programming the AnalyzerList of Supported SCPI Commands[:SENSe]:BWIDth|BANDwidth:SHAPe "Filter Type " on page 557[:SENSe]:BWIDth|BANDwidt
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceModeKey PathModeExample INST:SEL ISDBTINST:NSEL 239Initial S/W Revision A.03.00CMMBSelects
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceModeCombined Fixed WiMAXSelects the Combined Fixed WiMAX mode for general purpose measurem
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceModeIf you are using the Help feature, this mode must be currently active to access its de
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMode• RFID• Digital satellite video and other satellite signals, radar, LMDS• Up to 400K b
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceModeAfter changing into or out of this mode, allow a 1 second delay before sending any sub
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceModeINST:NSEL 106Initial S/W Revision A.10.01WLANSelects the WLAN mode for general purpose
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceModeGSM/EDGE/EDGE Evo 13 EDGEGSM802.16 OFDMA (WiMAX/WiBro) 75 WIMAXOFDMAVector Signal Anal
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceModeThe command must be sequential: i.e. continued parsing of commands cannot proceed unti
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceModeCurrent Application ModelReturns a string that is the Model Number of the currently se
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceModeThe format is the name as the *OPT? or SYSTem:OPTion command: a comma separated list o
3 Programming the AnalyzerList of Supported SCPI Commands[:SENSe]:DEMod "Analog Demod Tune & Listen" on page 845[:SENSe]:DEMod:AM:BANDw
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceModeString length is COUNt * 7 – 1. (7 = Model Number length + 1 for comma. –1 = no comma
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceModeDetailed List of ModesThis topic contains an alphabetical list of measurement applicat
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceModel "Noise Figure" on page 866l "Phase Noise" on page 866l "Rem
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMode PresetMode PresetReturns the active mode to a known state.Mode Preset does the follow
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMode Presetdoes a User Preset. The old PRESet:TYPE command is ignored (without generating
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMode PresetRestore Input/OutputDefaults:SYSTem:DEFault INPut System Menu; RestoreSystem De
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMode SetupMode SetupThis menu allows you to select 8560 series analyzer emulation, or 8566
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMode SetupSelecting any legacy analyzer from this menu performs an instrument preset and s
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMode SetupThis string is limited to the first 20 characters of the input string (message u
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMode SetupKey Path Mode Setup, LoggingRefreshTo update the log page with new entries, sele
3 Programming the AnalyzerList of Supported SCPI Commands[:SENSe]:FREQuency:SPAN:FULL "Full Span " on page 1146[:SENSe]:FREQuency:SPAN:PREV
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMode SetupPreset ONNotes If the selected RLC Language is HP8566A/B or HP8568A/B, setting t
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMode SetupSwp Type RuleChanges the Auto rules for determining whether the instrument uses
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMode SetupRestore Mode DefaultsResets the state for the currently active mode by resetting
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMode SetupWhen the Global Center Freq key is switched to On in any mode, the current mode’
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceMode SetupRemote Command:INSTrument:COUPle:DEFaultExample INST:COUP:DEFBackwardsCompatibil
6 RLC Swept SA Measurement Front-Panel &SCPI ReferencePeak SearchPeak SearchPressing the Peak Search key displays the Peak Search menu and place
6 RLC Swept SA Measurement Front-Panel &SCPI ReferencePeak Searchmany times as required to navigate back through the previously accessed menus u
6 RLC Swept SA Measurement Front-Panel &SCPI ReferencePeak SearchNext Pk LeftPressing Next Pk Left moves the selected marker to the nearest peak
6 RLC Swept SA Measurement Front-Panel &SCPI ReferencePeak SearchDependencies Same as specified under Marker ToInitial S/W Revision Prior to A.0
6 RLC Swept SA Measurement Front-Panel &SCPI ReferencePeak Search“Peak Search” CriteriaThis menu lets you decide what kind of search you want to
Table Of ContentsSyntax 242Legacy Products 242Description 242B2 [two] (Maximum Hold for Trace B) 243Syntax 243Legacy Products 243Description 243B3 [th
3 Programming the AnalyzerList of Supported SCPI Commands[:SENSe]:RLC:ATTenuation:STATe[:SENSe]:RLC:ATTenuation:STATe?"Atten Offset" on pag
6 RLC Swept SA Measurement Front-Panel &SCPI ReferencePeak SearchExample CALC:MARK:PEAK:SEAR:MODE MAXReadback Highest PeakInitial S/W Revision P
6 RLC Swept SA Measurement Front-Panel &SCPI ReferencePeak SearchIn the event that a sequence of trace points with precisely the same values rep
6 RLC Swept SA Measurement Front-Panel &SCPI ReferencePeak SearchPk ThresholdTurns the peak threshold requirement on/off and sets the threshold
6 RLC Swept SA Measurement Front-Panel &SCPI ReferencePeak SearchMore InformationThe Peak Threshold line is green and has the value of the peak
6 RLC Swept SA Measurement Front-Panel &SCPI ReferencePeak SearchThe Peak Table is updated after each sweep. The list of peaks in the Peak Table
6 RLC Swept SA Measurement Front-Panel &SCPI ReferencePeak SearchPreset AMPLitudeState Saved Saved in instrument state.BackwardsCompatibility SC
6 RLC Swept SA Measurement Front-Panel &SCPI ReferencePeak SearchMore InformationIf the Display Line (see the Section “View/Display”) is turned
6 RLC Swept SA Measurement Front-Panel &SCPI ReferencePeak SearchAbove Display LineSets the peak table to display only the 20 highest peaks abov
6 RLC Swept SA Measurement Front-Panel &SCPI ReferencePeak SearchKey PathPeak SearchRemote Command:CALCulate:MARKer[1]|2|...12:CPSearch[:STATe]
6 RLC Swept SA Measurement Front-Panel &SCPI ReferencePeak Searchmeasurement will be allowed to complete (i.e., all the averages taken up to the
3 Programming the AnalyzerList of Supported SCPI Commands[:SENSe]:SWEep:TIME:AUTO "Sweep Time" on page 1152[:SENSe]:SWEep:TIME:AUTO:RULes &
6 RLC Swept SA Measurement Front-Panel &SCPI ReferencePeak SearchCALC:MARK:Y? queries the delta amplitude value for marker 1.Notes Turns on the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferencePeak SearchRemote Command:TRACe:MATH:PEAK[:DATA]?Example TRAC:MATH:PEAK? Will identify the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceQuick SaveQuick SaveThe Quick Save front-panel key repeats the most recent save that was p
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceQuick SaveOne of the key features of Auto File Name is that we guarantee that the Auto Fil
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallRecallThe Recall menu lets you choose what you want to recall, and where you want to
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallThe content of a state file includes all of the settings and data required to return
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallnumber, the recall functiontries to recall as much as possible and returns a warning
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallas they were when saved. data will be exactly as they werewhen saved. Any traces th
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallEnables you to navigate to the center of the dialog that contains the list of files
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallFrom File…When you press “From File”, the analyzer brings up a Windows dialog and a
3 Programming the AnalyzerList of Supported SCPI Commands:SOURce[:EXTernal]:POWer[:LEVel][:IMMediate][:AMPLitude]"Amplitude" on page 1125:S
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallThe Look In field shows the path from which the file will be recalled and allows you
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallListed below are the functions of the various fields in the dialog, and the correspo
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallUser specified paths are remembered when you leave and return to a Mode and are rese
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallListed below are the functions of the various fields in the dialog, and the correspo
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallUser specified paths are remembered when you leave and return to a Mode and are rese
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallListed below are the functions of the various fields in the dialog, and the correspo
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallUser specified paths are remembered when you leave and return to a Mode and are rese
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallListed below are the functions of the various fields in the dialog, and the correspo
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallUser specified paths are remembered when you leave and return to a Mode and are rese
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallListed below are the functions of the various fields in the dialog, and the correspo
3 Programming the AnalyzerList of Supported SCPI CommandsStion-able:CA-Libration:EXTended:FAILure:PTRansition:STA-Tus:QUE-Stionable:CALibration:EXTen
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallUser specified paths are remembered when you leave and return to a Mode and are rese
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallListed below are the functions of the various fields in the dialog, and the correspo
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallUser specified paths are remembered when you leave and return to a Mode and are rese
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallListed below are the functions of the various fields in the dialog, and the correspo
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallUser specified paths are remembered when you leave and return to a Mode and are rese
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallListed below are the functions of the various fields in the dialog, and the correspo
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallUser specified paths are remembered when you leave and return to a Mode and are rese
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallListed below are the functions of the various fields in the dialog, and the correspo
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallUser specified paths are remembered when you leave and return to a Mode and are rese
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallAfter the recall completes, the message "Register <register number> recal
3 Programming the AnalyzerList of Supported SCPI Commands:STATus:QUEStionable:FREQuency:CONDition? "Questionable Frequency Condition" on pa
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallKey PathRecall, StateExample *RCL 1Range 1–16 from front panel, 1–128 from SCPIReadb
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallA custom name of up to 30 characters entered using the Save, State,Edit Register Nam
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallRegister 1 thru Register 16Selecting any one of these register keys causes the State
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallRegisters are shared by all modes, so recalling from any one of the registers will c
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallsaved in the Spectrum Analyzer Mode, then after the recall, you will still be in the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallExample *RCL 1Range 1–16 from front panel, 1–128 from SCPIReadback Date and time wit
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecall“(empty)" if no prior save operation has been performed to this register.Initia
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallRegister 1 thru Register 16Selecting any one of these register keys causes the State
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallRegisters are shared by all modes, so recalling from any one of the registers will c
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallsaved in the Spectrum Analyzer Mode, then after the recall, you will still be in the
3 Programming the AnalyzerList of Supported SCPI Commands:STATus:QUEStionable:NTRansition "Questionable Negative Transition " on page 145:S
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallExample *RCL 1Range 1–16 from front panel, 1–128 from SCPIReadback Date and time wit
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecall“(empty)" if no prior save operation has been performed to this register.Initia
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallTrace (+State)The Recall Trace (+State) menu lets you choose a register or file from
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallrecalled.Once the state is loaded, the trace data must be loaded. The internal flags
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallIf the .trace file is an "all trace" file, "ToTrace" is ignored
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallIf the .trace file is an "all trace" file, "ToTrace" is ignored
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallIf the .trace file is an "all trace" file, "ToTrace" is ignored
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallRegisters are shared by all modes, so recalling from any one of the registers will c
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallsaved in the Spectrum Analyzer Mode, then after the recall, you will still be in the
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallExample *RCL 1Range 1–16 from front panel, 1–128 from SCPIReadback Date and time wit
3 Programming the AnalyzerList of Supported SCPI Commands:SY-STem:CO-MMunicate:LAN:SCPI:TELNet:ENABle"SCPI Telnet" on page 1296:SYSTem:COMM
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecall“(empty)" if no prior save operation has been performed to this register.Initia
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallFrom File…When you press “From File”, the analyzer brings up a Windows dialog and a
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallThe Look In field shows the path from which the file will be recalled and allows you
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallListed below are the functions of the various fields in the dialog, and the correspo
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallUser specified paths are remembered when you leave and return to a Mode and are rese
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallListed below are the functions of the various fields in the dialog, and the correspo
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallUser specified paths are remembered when you leave and return to a Mode and are rese
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallListed below are the functions of the various fields in the dialog, and the correspo
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallUser specified paths are remembered when you leave and return to a Mode and are rese
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallListed below are the functions of the various fields in the dialog, and the correspo
3 Programming the AnalyzerList of Supported SCPI CommandsAPPLication:VMEMory:USED:NAME?:SYSTem:PON:ETIMe? "Query the Elapsed Time since First Po
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallUser specified paths are remembered when you leave and return to a Mode and are rese
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallListed below are the functions of the various fields in the dialog, and the correspo
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallUser specified paths are remembered when you leave and return to a Mode and are rese
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallListed below are the functions of the various fields in the dialog, and the correspo
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallUser specified paths are remembered when you leave and return to a Mode and are rese
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallListed below are the functions of the various fields in the dialog, and the correspo
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallUser specified paths are remembered when you leave and return to a Mode and are rese
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallListed below are the functions of the various fields in the dialog, and the correspo
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallUser specified paths are remembered when you leave and return to a Mode and are rese
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallListed below are the functions of the various fields in the dialog, and the correspo
3 Programming the AnalyzerList of Supported SCPI Commands:TRACe:MATH:MEAN? "Mean Trace Data (Remote Command Only) " on page 1391:TRACe:MATH
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallUser specified paths are remembered when you leave and return to a Mode and are rese
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallListed below are the functions of the various fields in the dialog, and the correspo
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallUser specified paths are remembered when you leave and return to a Mode and are rese
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecalldata. Pressing the Open key in this menu brings up the Open dialog and Open menu tha
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallExample :MMEM:LOAD:CORR 2 "myAmpcor.csv" recalls the Amplitude Correction
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallNotes auto returnDependencies Only Correction 1 may be used to load a Correction tha
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallNotes auto returnDependencies Only Correction 1 may be used to load a Correction tha
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallNotes auto returnDependencies Only Correction 1 may be used to load a Correction tha
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallTRACE6,<filename>Example :MMEM:LOAD:TRAC DATA TRACE2, "myTrace2.csv"
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallSelect TraceThese keys let you pick the Trace into which to import the data; either
3 Programming the AnalyzerList of Supported SCPI Commands:TRIGger[:SEQuence]:FRAMe:RFBurst:SLOPe"Trigger Slope " on page 1429:TRIGger[:SEQu
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallSelect TraceThese keys let you pick the Trace into which to import the data; either
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallSelect TraceThese keys let you pick the Trace into which to import the data; either
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallCouplings When a limit line is loaded from mass storage, it is automatically turned
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallAn example of using this menu is: If you select 2 and continue to the File Open menu
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallPreset Not part of Preset, but is reset to LLINE1 by Restore Mode Defaults; survives
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallOpen…When you press “Open”, the analyzer brings up a Windows dialog and a menu entit
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallOpen…When you press “Open”, the analyzer brings up a Windows dialog and a menu entit
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallOpen…When you press “Open”, the analyzer brings up a Windows dialog and a menu entit
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRecallOpen…When you press “Open”, the analyzer brings up a Windows dialog and a menu entit
6 RLC Swept SA Measurement Front-Panel &SCPI ReferenceRestartRestartThe Restart function restarts the current sweep, or measurement, or set of a