68 Agilent E1330B Digital I/O Module Command Reference
Chapter 5
MEMory Subsystem
The MEMory subsystem defines the command set for enabling the use of external
VME memory for storing traces and macros. The addressable range is #H200000
through #HDFFFF8 in A24 space.
Syntax MEMory
:DELete
:MACRo <
name>
:VME
:ADDRess [<
base>]<address>
:ADDRess? [MIN|MAX]
:SIZE [<
base>]<size>
:SIZE? [MIN|MAX]
:STATe <
state>
:STATe?
:DELete:MACRo
MEMory:DELete:MACRo <name> deletes a single macro previously recorded
using the
*DMC common command.
Parameters
Comments name must have been previously defined by a *DMC (Define Macro) common
command.
The maximum length for name is 12 characters.
This command purges a single, specific macro; the *PMC common command
purges all macros.
Example MEM:DEL:MACR test_macro deletes macro named test_macro previously defined
using the
*DMC common command.
Parameter Name Parameter Type Range of Values Default
<
name>
String Previously defined block name
(maximum 12 characters)
None