Agilent Technologies E1330B Manual de usuario Pagina 74

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 156
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 73
72 Agilent E1330B Digital I/O Module Command Reference
Chapter 5
[SOURce:] Subsystem
The [SOURce:] subsystem defines the command set for the Digital I/O module
output statements. It also defines the state and polarity of the control line (CTL), the
polarity of the flag line (FLG), the handshaking mode, and handshake delay for both
data input and output. The root command,
[SOURce:], is optional.
[SOURce:]
DIGital
:CONTrol
n
:POLarity <POS|NEG>
:POLarity?
[:VALue] <0|1
or ON|OFF>
[:VALue]?
:DATAn
[:BYTE]
:BIT
m <0|1>
:BIT
m?
:HANDshake
:DELay <
time>
:DELay?
[:MODE] <NONE|LEADing|TRAiling
|PULSe|PARTial|STRobe>
[:MODE]?
:POLarity <POS|NEG>
:POLarity?
:TRACe <
name>
[:VALue] [<
base>]<value>
[:VALue]?
:LWORd
:BIT
m <0|1>
:BIT
m?
:HANDshake
:DELay <
time>
:DELay?
[:MODE] <NONE|LEADing|TRAiling
|PULSe|PARTial|STRobe>
[:MODE]?
:POLarity <POS|NEG>
:POLarity?
:TRACe <
name>
[:VALue] [<
base>]<value>
[:VALue]?
Vista de pagina 73