52 Relay Multiplexer Command Reference
:COUNt?
ARM:COUNt? [MIN|MAX] returns current number of scanning cycles set by
ARM:COUNt. A value is supplied if no MIN or MAX parameter is sent. With MIN or
MAX passed as parameters, MIN returns 1 and MAX returns 32767.
Parameters
Comments
Related Commands: INITiate[:IMMediate]
Example Query Number of Scanning Cycles
ARM:COUN 10
Sets 10 scanning cycles.
ARM COUN?
Query number of scanning cycles;
returned value is 10.
Parameter Name Parameter Type Range of Values
MIN|MAX numeric MIN=1, MAX=32767