FUNCtion:CSINusoid
This command sets the clipping level when a clipped sine output waveform is selected. The clipping
characteristics can be specified in two ways:
u The clipping level is expressed as a percentage of the peak amplitude at which clipping occurs.
The range is 0 to 100 percent. These are the default units when the optional THD suffix is not
sent.
u The clipping level is expressed at the percentage of total harmonic distortion in the output voltage.
The range is 0 to 43 percent. The optional THD suffix is sent to program in these units.
Command Syntax
[SOURce:]FUNCtion[:SHAPe]:CSINusoid <Nrf> [THD]
Parameters
0 to 100% | 0 to 43% THD
*RST Value
100% | 0% THD (no clipping)
Examples
FUNC:CSIN 80 FUNC:CSIN 10 THD
Query Syntax
[SOURce:]FUNCtion[:SHAPe]:CSINusoid?
Returned Parameters
<NR3>
Related Commands
FUNC FUNC MODE