93
VOLTage:SLEW:MODE
Phase Selectable
This command determines how the output voltage slew rate is controlled during a triggered output
transient. The choices are:
FIXed
The slew rate is unaffected by a triggered output transient.
STEP
The slew rate is programmed to the value set by VOLTage:SLEW:TRIGgered when a
triggered transient occurs.
PULSe
The slew rate is changed to the value set by VOLTage:SLEW:TRIGgered for a duration
determined by the pulse commands.
LIST
The slew rate is controlled by the voltage slew list when a triggered transient occurs.
Command Syntax
[SOURce:]VOLTage:SLEW:MODE <mode>
Parameters
FIXed | STEP | PULSe | LIST
*RST Value
FIXed
Examples
VOLT:SLEW:MODE STEP
Query Syntax
[SOURce:]VOLTage:SLEW:MODE?
Returned Parameters
<CRD>
Related Commands
VOLT:SLEW VOLT:SLEW:TRIG
VOLTage:SLEW:TRIGgered
Phase Selectable
This command selects the slew rate that will be set during a triggered step or pulse transient. A parameter
of MAXimum or INFinity sets the slew to its maximum possible rate. The SCPI representation for infinity is
9.9E37.
Command Syntax
[SOURce:]VOLTage:SLEW:TRIGgered <NRf+> | INFinity
Parameters
0 to 9.9E37 | MAXimum | MINimum | INFinity
Unit
V
(volts per second)
*RST Value
INFinity
Examples
VOLT:SLEW:TRIG 50 VOLT:SLEW:TRIG MAX
Query Syntax
[SOURce:]VOLTage:SLEW:TRIGgered?
Returned Parameters
<NR3>
Related Commands
VOLT:SLEW VOLT:SLEW:MODE