Agilent Technologies N9344C Manual de servicio Pagina 119

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 224
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 118
Command Reference 5
Programmer’s Guide 111
Query Upper Adjacent Channel Power Ratio
:MEASure:ACPRatio:UPPer?
Return the upper adjacent channel power to main channel power ratio.
ACPR RRC Filter State
[:SENSe]:ACPRatio:RRC[:STATe] OFF|ON|0|1
[:SENSe]:ACPRatio:RRC[:STATe]?
Use this command to turn on/off the RRC filter.
Example: :ACPRatio:RRC 1
Key access: Meas > RRC filter > On/Off
ACPR RRC Filter Alpha Value
[:SENSe]:ACPRatio:RRC:ALPHa <val>
[:SENSe]:ACPRatio:RRC:ALPHa?
Use this command to set the alpha value of RRC filter.
Example: :ACPRatio:RRC:ALPHa 0.35
Key access: Meas > RRC filter
CHP Subsection
Center Freq
[:SENSe]:CHPower:FREQuency:CENTer <freq>
[:SENSe]:CHPower:FREQuency:CENTer?
Sets the center frequency of the display.
Example: :CHPower:FREQuency:CENTer 4 GHz
Key access: Meas > Center Freq
Vista de pagina 118
1 2 ... 114 115 116 117 118 119 120 121 122 123 124 ... 223 224

Comentarios a estos manuales

Sin comentarios