Example Enabling Frequency Doubling
FUNC:SHAP SQU Selects square wave output.
ROSC:SOUR INT1 Selects 42.94 MHz oscillator.
FREQ:RANG 5MHZ Sets frequency range to 5 MHz.
:SPAN
[SOURce:]FREQuency[1]:SPAN <freq_span> sets the sample rate or waveform
frequency span for a frequency-swept waveform.
Parameters
Parameter
Name
Parameter
Type
Range of
Values
Default
Units
<
freq_span>
numeric see below | MINimum | MAXimum Hz
The legal range for <
freq_span>, as well as the MINimum and MAXimum values, are
context-dependent. See Coupling Rules” on page 319 for a description of the coupling
between STARt, STOP, CENTer, and SPAN.
Comments Executable when Initiated: Query form only
Coupling Group: Frequency
Related Commands: TRIGger[:STARt]:SOURce,
[SOURce:]FREQuency[1]:CENTer, MODE, RANGe, STARt, and STOP,
[SOURce:]FUNCtion[:SHAPe], [SOURce:]ROSCillator commands
*RST Condition: SOURce:FREQuency1:SPAN 10.73741824 MHz
Example Setting the Frequency Span
FREQ:SPAN 1E3 Sets the frequency span to 1000 Hz.
[SOURce:]FREQuency[1]
Chapter 8 Command Reference 327