Parameters
Parameter
Name
Parameter
Type
Range of
Values
Default
Units
<
source> string ARM[:STARt|:SEQuence[1]][:LAYer[1]]” |
ARM[:STARt|:SEQuence[1]]:LAYer2” |
[SOURce:]FREQuency[1]:CHANge” |
[SOURce:]LIST[1]” |
[SOURce:]PM:DEViation:CHANge”
[SOURce:]ROSCillator” |
TRIGger[:STARt|:SEQuence[1]]”
none
Comments Executable when Initiated: Yes
Coupling Group: None
Related Commands: [SOURce:]MARKer:ECLTrg<n>[:STATe]
*RST Condition:
[SOURce:]MARKer:ECLTrg0:FEED ARM[:STARt|:SEQuence[1]][:LAYer[1]]”,
[SOURce:]MARKer:ECLTrg1:FEED TRIGger[:STARt|:SEQuence[1]]
Example Setting the VXI ECLTRG0 Trigger Line Source
MARK:ECLT0:FEED “SOUR:LIST” Sets marker list as source.
:ECLTrg<n>[:STATe]
[SOURce:]MARKer:ECLTrg<n>[:STATe] <mode> enables or disables the routing
of the selected marker signal (
[SOURce:]MARKer:ECLTrg<n>:FEED command) to
the specified VXIbus ECL trigger line (
ECLTRG0 or ECLTRG1).
Parameters
Parameter
Name
Parameter
Type
Range of
Values
Default
Units
<
mode> boolean OFF | 0 | ON | 1 none
Comments Executable when Initiated: Yes
Coupling Group: None
Related Commands: [SOURce:]MARKer:ECLTrg<n>:FEED
*RST Condition: SOURce:MARKer:ECLTrg<n>:STATe OFF
Example Enabling Marker Output to ECLTRG0*
MARK:ECLT0 ON Enables ECLTRG0*.
[SOURce:]MARKer