Agilent Technologies E8257C PSG Guía de usuario Pagina 114

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 220
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 113
104 Chapter 5
Dual Arbitrary Waveform Generator
Using Waveform Markers
Using Waveform Markers
Waveform markers provide auxiliary output signals that are synchronized with a waveform segment. You
can place up to four markers on a waveform segment. However, only Marker 1 and Marker 2 can be placed
using the waveform players user interface (for more information, refer to “Waveform Marker Concepts” on
page 108).
Using markers, you can construct an output signal as a trigger to synchronize another instrument to a given
portion of a waveform. You can also place markers into a waveform sequence, either as the sequence is
being built or within an existing waveform sequence.
For instructions on verifying marker operation, see “To Verify Marker Operation” on page 107.
To Place a Marker at the First Point within a Waveform Segment
If you have not created a waveform segment, complete the steps in the previous sections, “Generating the
First Waveform” on page 100 and “Creating the First Waveform Segment” on page 100.
1. Press
Mode > Dual ARB > Waveform Segments.
2. Press
Load Store.
3. Highlight a waveform segment (for example, TTONE).
4. Press
Waveform Utilities > Set Markers > Set Marker On First Point.
This sets Marker 1 (selected by default) on the first point in the selected waveform segment.
To Place a Marker Across a Range of Points within a Waveform Segment
If you have not created a waveform segment, complete the steps in the previous sections, “Generating the
First Waveform” on page 100 and “Creating the First Waveform Segment” on page 100.
1. Press
Mode > Dual ARB > Waveform Segments.
2. Press
Load Store.
3. Highlight a waveform segment (for example, TTONE).
4. Press
Waveform Utilities > Set Markers > Set Marker On Range Of Points.
5. Press
First Mkr Point > 10 > Enter.
6. Press
Last Mkr Point > 163830 > Enter.
7. Press
Apply To Waveform.
NOTE The last marker point must be greater than or equal to the first marker point.
This activates Marker 1 (selected by default) from point 10 to point 163830 in the selected waveform
segment.
Vista de pagina 113
1 2 ... 109 110 111 112 113 114 115 116 117 118 119 ... 219 220

Comentarios a estos manuales

Sin comentarios