Now you need to rerun the Start-up Resource Manager by exiting Windows
and turning the VXI Mainframe Off and then On. Notice the
Commander/Servant Hierarchy and interrupt map portions of the EPC7 VXI
System Configuration Screen. Verify that the commander/servant hierarchy
and interrupt lines have been assigned as intended. See Figure 5-5 for an
example.
Where To Go Next Continue with Procedure 6 - "System Programming and Debugging". This
procedure enables you to verify that your computer is communicating with
the system, and contains guidelines for debugging your programs.
VXI System Configuration
.
.
Commander/Servant Hierarchy
TopCmdr
Agilent E1406A
Agilent E1411B
- - Interrupt Map - - IRQ
Device Name Interrupter 7 6 5 4 3 2 1 Handler
Cmdmod [H1]
TopCmdr [H2]
TopCmdr [H3]
TopCmdr [H4]
TopCmdr [H5]
TopCmdr [H6]
TopCmdr [H7]
Figure 5-5. Edited RADI-EPC7 Configuration
C-Size Configuration Guide Applying Power 5-13