EPC7-6 : Apply Power
When power is applied to the mainframe, the Start-Up Resource Manager
(SURM) on the EPC7 will execute. An example of the configuration
sequence is shown in Figure 2-48.
Use the Pg Up / Pg Dn keys to view the entire configuration. Pay particular
attention to the Slot Reporting and ULA (Unique Logical Address). These
items will help you confirm a proper installation. Press ESC to exit the
EPC7 start-up Resource Manager.
When you have a Agilent RADI-EPC7 and a Command Module in the
same system, you may want to change the commander/servant hierarchy so
that selected instruments report to the Command Module instead of the
EPC7. See the "Agilent RADI-EPC7 Embedded Computer" section in
Procedure 5, "Apply Power," for information on this procedure.
NOTE Refer to the EPConnect/VXI for DOS User’s Guide for more information on
the Agilent RADI-EPC7 resource manager configuration sequence and for
information on configuration and start up errors.
C-Size Configuration Guide Setting Up an Embedded RADI-EPC7 Computer 2-61