23
Cross-band spurious (for example, GSM900 into DCS1800)
In some countries GSM900 and DCS1800 systems exist together and in some
cases base stations for both systems are co-sited. For this reason the ETSI
standards require specific cross-band performance. For example GSM900
transmitters must put a minimum of energy into DCS1800 Tx and Rx bands
and vice-versa.
Graphical view of limits and specifications
Practical measurements
In practice cross-band spurious measurements are grouped with Tx and Rx
band spurious measurements and the same techniques are used. The principles
described in the explanation of theory in pictures and practical measurements
in the spurious section apply.
When to use the measurement
Applied as Tx and Rx band spurious.
Freq (MHz)
Power
(dBc)
Example: conducted, E-GSM900, normal BTS, multi-channel
925
1710
1785
1880
1805
960
98 dBm
(Applies when cositing
E-GSM and DCS)
47 dBm
DCS1800 Rx band
DCS1800 Tx band
E-GSM900 Tx band
Channels and slots:
B, M, T
Hopping:
Off
RBW:
30 kHz and 100 kHz
VBW:
=RBW
Detection:
Peak
Sweep
Figure 19. Cross-band spurious, BTS, limits
Vista de pagina 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 35 36