Choosing transmitter measurements for an application
The following table is given for guidance only and the actual measurement set
used in any one application is dependent on a number of factors (for example,
transmitter design, integration level, or calibration requirements).
R&D Yes Yes Yes Yes Yes Yes Yes Yes Yes
Verification Yes Yes Yes Yes Yes Yes Yes Yes Yes
Type approval Yes Yes Yes Yes Yes Yes Yes Yes Yes
Module test Yes Yes Yes Most Most Some Some Few No
Final test Yes Yes Yes Most Most Some Some Few No
QA test Yes Yes Yes Yes Yes Most Most Some Some
Installation Yes Yes Yes Most Most Some Some Few Some
Maintenance Yes Yes Yes Some Some Some No No Some
Depot repair Yes Yes Yes Most Most Some Some Few Some
Phase error and mean frequency error
Mean transmitted RF carrier power
Transmitted RF carrier power versus time
Spectrum due to modulation and wideband noise
Spectrum due to switching
Tx and Rx band spurious
Cross-band spurious
Wide band spurious
Other transmitter measurements
(not described in this application note)
BTS
Lifecycle
Phase
Figure 21. BTS measurements by application/lifecycle phase