Agilent Technologies J-BERT N4903B Manual de servicio Pagina 30

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 406
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 29
Table 2
Bit Mnemonic Description
4 EXE Execution error bit. It is set
when a command (GPIB
instrument specific)
cannot be executed due to
an out of range parameter
or some instrument
condition that prevents
execution.
5 CME Command error bit. It is set
whenever the instrument
detects an error in the
format or content of the
program message (usually
a bad header, missing
argument, or wrong data
type etc.).
6 Not used
7 PON Power-on bit. It is set each
time the instrument is
powered from off to on.
8-15 Not used
N O T E
This register is compatible with the generalized status register model. It is
comprised of an event and enable register, but no condition register or transition
filter. All positive transitions in this register are latched.
Clock Loss Register
The Clock Loss Register group indicates whether the pattern generator or error
detector has experienced a clock signal loss. The output of this register sets bits
5 and 9 (Clock Loss) in the Questionable Status Register.
3 Recommended Programming Techniques
30 Agilent J-BERT N4903B High-Performance Serial BERT
Vista de pagina 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 405 406

Comentarios a estos manuales

Sin comentarios