InfiniiMax Active Probe System Overview - InfiniiMax II Probing System
Overcoming measurement challenges with Infi niiMax probe
Infi niiMax probe is not just for
Infi niium scope.
The benefi ts of Agilent’s award winning In-
niiMax probes are not restricted to Agilent
Infi niium oscilloscopes. A variety of acces-
sories are available that allow you to use
Infi niiMax probes with other test equipment,
such as spectrum analyzers and sampling
oscilloscopes.
To learn more about how to use the Infi -
niiMax probe with your test equipment other
than Agilent Infi niium oscilloscopes, refer to
the Agilent literature number 5989-1869EN.
Operating at high or low
temperatures
You may need to monitor a system in a
temperature chamber with an oscilloscope
probe to verify performance over a wide
range of operating temperatures, or to
determine the cause of failures at high or
low temperatures. Agilent Infi niiMax I/II
probe amplifi ers have a specifi ed operating
temperature range from 5° C to 40°C. How-
ever, the probe heads can be operated over
a much wider range. You can use the Agilent
N5450A extension cable set to physically
separate the probe heads from the probe
amplifi ers. This will allow you to operate the
probe heads inside a temperature chamber
with the probe amplifi er located outside the
temperature chamber. To learn more about
how to extend the operating range of the
Infi niiMax probes in temperature, refer to
the Agilent literature number 5989-7587EN.
Increasing the voltage dynamic
range and offset range
The dynamic range of the Infi niiMax probes
is 5 V p-p for Infi niiMax I and 3.3 V p-p for
Infi niiMax II. For applications that need to
measure larger signals with faster edges,
the N2880A in-line coaxial attenuator kit
allows you to increase the dynamic range
of the probe system up to 50 Vpp and the
offset range up to +/-30V, without affecting
the bandwidth or rise time characteristics of
the probe system. The N2881A DC blocking
capacitors can be used in series with the
N2880A Infi niiMax in-line attenuator to
block out unwanted DC components of the
input signal up to 30 V. To learn more about
how to extend the operating range of the
Infi niiMax probes in input range, refer to the
Agilent literature number 5989-7587EN.
How would I measure small AC
riding on top of large DC with
Infi niiMax probe?
It is challenging to measure very small
signals riding on top of large signals with
scopes, as most scopes have limited
dynamic ranges and offset ranges. Consider
using an Infi niiMax active probe which
provides a huge offset range that can allow
you to make measurements you need. To
learn more about how to use the Infi niiMax
probe’s offset range, refer to the Agilent
literature number 5990-8255EN and 5988-
9264EN.
plus probe tip
minus probe tip
differential
amplifi er
probe scope
scope channel
probe offset
used when probing
signal ended signals
normal scope
channel offset
used when probing
differential signals
note: minus probe tip not present if
using signal-ended probe heads